Saunier Duval Thema C23 / F23 Control PCB - Ref. ST1407 CA04003
If your boiler does not start, locks out, or exhibits erratic behavior, you may need the Saunier Duval Thema C23 / F23 Control PCB - Ref. ST1407 CA04003. This control board is responsible for managing the ignition, burner modulation, pump, and safety features of the boiler. When it fails, fault codes 12, 18, or 20 may appear. It is compatible with the Thema C 23 and F 23 models, among others. It is recommended to replace it upon noticing these symptoms to ensure proper operation.
VAT included
Consult via WhatsAppSaunier Duval boilers compatible with reference 05727900
PCB with reference 05727900. Two confirmed compatibilities: C 23 and F 23.
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Saunier Duval C 23 | Thema | Contrasted |
| Saunier Duval F 23 | Thema | Contrasted |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if the ref. 05727900 is the part for your boiler
What determines it is not the boiler model, but the reference printed on the part you already have installed.
- Find the reference printed on the installed part and check whether it matches the catalogue reference 05727900. If it is not visible, do not identify the part from its shape alone.
- Check the full boiler model on its data plate and look for it in the model associations on this page.
- Compare the connections and physical body with the original part before installation.
- If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Symptoms and faults that the PCB 05727900 resolves.
The PCB controls the ignition, modulation, and safety features of the boiler. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
The temperature controls of the boiler do nothing: you raise or lower them and the behavior of the burner does not change.
Cause: The control board does not correctly receive the commands from the controls, so it cannot modulate the flame.
Before replacing it, check that the physical controls turn normally and are not broken or loose inside.
- 02
The boiler does not respond to the room thermostat: it stays on all the time or does not start even when the thermostat requests it.
Cause: The control board does not receive the signal from the thermostat, so it cannot decide whether to start the burner.
Bridge the two thermostat wires directly in the boiler terminal block to see if it starts; if it starts this way, the problem is with the thermostat or the wiring.
- 03
Some pilot light or LED on the boiler is flashing in a strange pattern, or stays on in red, without any noticeable gas or water fault.
Cause: A fault in the electronics of the PCB can cause the LEDs to display a code that is not related to the rest of the installation.
Note the exact pattern of the blinking (number of flashes, color) and compare it with the fault code table in the manual.
- 04
The domestic hot water and heating are conflicting with each other: it heats what it shouldn't or takes too long to switch from one service to another.
Cause: The control board is not properly managing the priority of the circuits, which is causing conflicts between them.
Make sure to check that the demand for domestic hot water (turning on a hot water tap) is really noticeable before assuming that the fault is with the PCB.
Fault codes from Saunier Duval that this spare part resolves.
| Code | Fault | Diagnosis and solution |
|---|---|---|
| 12 | User interface or remote control panel fault | The control board/display does not respond on the bus (MMI) due to an internal fault or the remote control. Check 5 V on the display, continuity of the MMI harness, and if it persists, try replacing the control module (05727900). |
| 18 | Local user interface fault | Intrinsic fault in the display/control platform electronics. Check power supply voltages and interface wiring; if correct and the error persists, replace the control module. |
| 20 | User interface not compatible with boiler | The installed control board does not match the boiler's variant/device code (DSN) or is not coded. Verify the exact reference and reconfigure the variant/DSN or install the display compatible with the main PCB. |
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Data sheet for the Saunier Duval 05727900 PCB.
- Catalogue reference
- 05727900
- Brand
- Saunier Duval
- Type of part
- PCBs (control boards)
- Units in stock
- 1 unit
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- 1-2 business days
- Return
- 14 days
Data read on the part and in the manufacturer's documentation
What we have not been able to verify does not appear here.
- PCB code
- ST1407 CA04003
- Marking of switch SW1
- TY-F1D 94V-0
Manuals and technical documentation
Official documentation of the boiler, useful for locating the part and cross-referencing the fault codes.
- Saunier Duval F 23 manual (PDF)Document © Saunier Duval, provided as a technical reference.