PCB Saunier Duval Thema C 23 E
The Saunier Duval Thema C 23 E PCB is the component that controls the ignition, the modulation of the burner, the pump, and the safety features of the boiler. When it fails, the boiler may not start, may lock out, or may exhibit erratic operation. This PCB is compatible with several models, including Thema C 23 E, Thema F 23 E, Thema C AS 23 E, Thema F AS 23 E, Themaplus C 23 E, and Combitek C 23 E, among others. It is recommended to replace it when the mentioned symptoms occur.
VAT included
Consult via WhatsAppSaunier Duval boilers compatible with reference 05741000
PCB with reference 05741000. Eight confirmed compatibilities: C 23 E and F 23 E.
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Saunier Duval C 23 E | Thema | Contrasted |
| Saunier Duval F 23 E | Thema | Contrasted |
| Saunier Duval C AS 23 E | Thema | Contrasted |
| Saunier Duval F AS 23 E | Thema | Contrasted |
| Saunier Duval C 23 E | Themaplus | Contrasted |
| Saunier Duval F 23 E | Themaplus | Contrasted |
| Saunier Duval C 23 E | Combitek | Contrasted |
| Saunier Duval F 23 E | Combitek | Contrasted |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if ref. 05741000 is the part for your boiler
What determines it is not the boiler model, but the reference printed on the part you already have installed.
- Find the reference printed on the installed part and check whether it matches the catalogue reference 05741000. If it is not visible, do not identify the part from its shape alone.
- Check the full boiler model on its data plate and look for it in the model associations on this page.
- Compare the connections and physical body with the original part before installation.
- If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Symptoms and faults that the PCB 05741000 resolves.
The PCB controls the ignition, modulation, and safety features of the boiler. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
The heating or domestic hot water temperature cannot be adjusted properly, or it fluctuates on its own.
Cause: The potentiometers on the PCB regulate those parameters; if the contact is dirty or damaged, the adjustment fails.
Turn the temperature knob from one end to the other several times before changing the PCB; sometimes it releases the dirty contact.
- 02
The boiler is functioning strangely, as if the settings have changed by themselves.
Cause: The DIP micro switches on the PCB set the operating mode; a faulty contact alters the behavior.
Check that the micro switches are still in their original position before replacing the PCB, in case they have been accidentally moved.
- 03
It turns on but always operates at the same level, as if it doesn't modulate.
Cause: The PCB is not varying the signal that controls the gas valve or the fan.
Check if the fault occurs the same in heating and in domestic hot water; if it only happens in one of the two, it is probably not the PCB.
- 04
There are no signs of life: the display is off, it does not respond to anything.
Cause: General fault of the PCB that cuts off the supply to all control electronics.
Check the fuse and the 230V power supply before declaring the PCB as faulty.
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Data sheet for the Saunier Duval 05741000 PCB.
- Catalogue reference
- 05741000
- Brand
- Saunier Duval
- Type of part
- PCBs (control boards)
- Units in stock
- 4 units
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- 1-2 business days
- Return
- 14 days
Data read on the part and in the manufacturer's documentation
What we have not been able to verify does not appear here.
- Potentiometer
- Brand KOKA
Manuals and technical documentation
Official documentation of the boiler, useful for locating the part and cross-referencing the fault codes.
- Saunier Duval C AS 23 E Manual (PDF)Document © Saunier Duval, provided as a technical reference.