Saunier Duval Themaplus F 23 E PCB (control board)
The Saunier Duval Themaplus F 23 E PCB is the component that controls the ignition, the modulation of the burner, the pump, and the safety features of the boiler. When this part fails, the boiler may not start, become locked, or exhibit erratic operation. It is compatible with several models from the Thema and Themaplus ranges, such as the C 23 E and the F 23 E, among others. Replacement should be carried out when these symptoms occur, as it affects the operation of the boiler.
VAT included
Consult via WhatsAppSaunier Duval boilers compatible with reference 05741000
PCB with reference 05741000. Eight confirmed compatibilities: C 23 E and F 23 E.
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Saunier Duval C 23 E | Thema | Contrasted |
| Saunier Duval F 23 E | Thema | Contrasted |
| Saunier Duval C AS 23 E | Thema | Contrasted |
| Saunier Duval F AS 23 E | Thema | Contrasted |
| Saunier Duval C 23 E | Themaplus | Contrasted |
| Saunier Duval F 23 E | Themaplus | Contrasted |
| Saunier Duval C 23 E | Combitek | Contrasted |
| Saunier Duval F 23 E | Combitek | Contrasted |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if ref. 05741000 is the part for your boiler
What determines it is not the boiler model, but the reference printed on the part you already have installed.
- Find the reference printed on the installed part and check whether it matches the catalogue reference 05741000. If it is not visible, do not identify the part from its shape alone.
- Check the full boiler model on its data plate and look for it in the model associations on this page.
- Compare the connections and physical body with the original part before installation.
- If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Symptoms and faults that the PCB 05741000 resolves.
The PCB controls the ignition, modulation, and safety features of the boiler. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
The boiler locks out by itself a few minutes after starting to operate.
Cause: The PCB controls the safety of the equipment and cuts off the supply if it detects something abnormal.
Note if the lockout occurs consistently in the same phase (ignition, heating) to better identify the source.
- 02
There is no spark or ignition attempt when heat is requested.
Cause: The PCB sends the ignition command to the electrode and the gas valve; if it fails, there is no ignition attempt.
Check the electrode and its high voltage cable before blaming the PCB.
- 03
The boiler always operates at maximum power, it doesn't decrease even when it's not needed.
Cause: If the PCB does not send the correct signal to the gas valve, the modulation remains at maximum.
Check that the temperature sensor is properly connected and not damaged before replacing the PCB.
- 04
The fault indicator is flashing in a pattern that doesn't match any code in the Saunier Duval manual.
Cause: A blink that does not match the fault code table usually indicates a fault in the electronics that manages that signaling.
Count the blinks and pauses slowly several times; sometimes the code exists but is counted incorrectly the first time.
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Data sheet for the Saunier Duval 05741000 PCB.
- Catalogue reference
- 05741000
- Brand
- Saunier Duval
- Type of part
- PCBs (control boards)
- Units in stock
- 5 units
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- 1-2 business days
- Return
- 14 days
Data read on the part and in the manufacturer's documentation
What we have not been able to verify does not appear here.
- Brand printed on the PCB
- SAUNIER DUVAL
- Partial marking of PCB
- ST148
- Mounted relay/transformer code
- 22S95-A
- Coil voltage of relay/transformer 22S95-A
- 24V
- Power of the relay/transformer 22S95-A
- 48V 0.05VA
- Additional relay marking
- 24V 56/000C · 48V 005V/1B 70JB
- Laminated PCB marking
- 1293 94V-0 fuba T
Manuals and technical documentation
Official documentation of the boiler, useful for locating the part and cross-referencing the fault codes.
- Saunier Duval F 23 E Manual (PDF)Document © Saunier Duval, provided as a technical reference.