Saunier Duval PCB Control Board Thematek SF24E Ref. S10470
The Saunier Duval Electronic PCB Thematek SF24E is the component that controls the ignition, burner modulation, pump, and safety features of the boiler. When it malfunctions, the boiler may fail to start, lock out, or behave erratically, displaying fault codes such as F13, F11, F12, or F18. This module is compatible with several boilers, including models F 25 E, F 24 E, C 24 E, and C 25 E, among others. It should be replaced when these symptoms or any malfunction associated with the PCB are noticed.
VAT included
Consult via WhatsAppSaunier Duval boilers compatible with reference S10470
PCB with reference S10470. 33 verified compatibilities: F 25 E and F 24 E.
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Saunier Duval F 25 E | ThemaClassic | Contrasted |
| Saunier Duval F 24 E | ThemaClassic | Contrasted |
| Saunier Duval C 24 E | ThemaClassic | Contrasted |
| Saunier Duval C 25 E | ThemaClassic | Contrasted |
| Saunier Duval C AS 24 E | ThemaClassic | Contrasted |
| Saunier Duval C AS 25 E | ThemaClassic | Contrasted |
| Saunier Duval F AS 24 E | ThemaClassic | Contrasted |
| Saunier Duval F AS 25 E | ThemaClassic | Contrasted |
| Saunier Duval F AS 30 E | ThemaClassic | Contrasted |
| Saunier Duval C 24 E | Themafast | Contrasted |
| Saunier Duval C 25 E | Themafast | Contrasted |
| Saunier Duval C 28 E | Themafast | Contrasted |
| Saunier Duval C 30 E | Themafast | Contrasted |
| Saunier Duval F 24 E | Themafast | Contrasted |
| Saunier Duval F 25 E | Themafast | Contrasted |
| Saunier Duval F 25 E H-MOD | Themafast | Contrasted |
| Saunier Duval F 30 E | Themafast | Contrasted |
| Saunier Duval F 30 E H-MOD | Themafast | Contrasted |
| Saunier Duval C 24 E | Thematek | Contrasted |
| Saunier Duval C 24 EO BT | Thematek | Contrasted |
| Saunier Duval F 24 E | Thematek | Contrasted |
| Saunier Duval S C 24 E | Thematek | Contrasted |
| Saunier Duval S F 24 E | Thematek | Contrasted |
| Saunier Duval C 24 EA | Isotwin | Contrasted |
| Saunier Duval C 28 EA | Isotwin | Contrasted |
| Saunier Duval C 24 E ad04 | Isotwin | Contrasted |
| Saunier Duval C 24 E de04 | Isotwin | Contrasted |
| Saunier Duval F 24 E | Isotwin | Contrasted |
| Saunier Duval F 24 EA | Isotwin | Contrasted |
| Saunier Duval F 28 EA | Isotwin | Contrasted |
| Saunier Duval F 30 E H-MOD | Isofast | Contrasted |
| Saunier Duval F 35 E H-MOD | Isofast | Contrasted |
| Saunier Duval F 25 E STL | Thema | Contrasted |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if ref. S10470 is the part for your boiler
What determines it is not the boiler model, but the reference printed on the part you already have installed.
- Find the reference printed on the installed part and check whether it matches the catalogue reference S10470. If it is not visible, do not identify the part from its shape alone.
- Check the full boiler model on its data plate and look for it in the model associations on this page.
- Compare the connections and physical body with the original part before installation.
- If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Symptoms and faults that the PCB S10470 resolves
The PCB controls the ignition, modulation, and safety features of the boiler. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
The remote control screen is off even though the boiler is powered.
Cause: The control module does not turn on if its internal circuit fails, even if the rest of the boiler is functioning.
Check that the connector between the module and the PCB is properly fitted and free of rust before replacing the module.
- 02
The buttons do not respond or need to be pressed several times to do anything.
Cause: The internal contacts of the module's keyboard lose sensitivity with use.
Clean the area around the buttons and try with the boiler cold; sometimes the problem is just dirt or moisture.
- 03
The temperature cannot be increased or decreased from the control.
Cause: If the module fails, the temperature command does not reach the PCB even though the boiler is ready to heat.
Check if the same adjustment works in the manual mode of the PCB to rule out that the fault is in the module.
- 04
The remote control loses the time or programming every few days.
Cause: The configuration is saved with a small internal battery or capacitor that depletes over time.
Reprogram the time and check if it only loses time after a power cut or if it happens all the time.
- 05
Symbols are flashing randomly on the screen or segments are not lighting up.
Cause: The display of the module may fail, showing incomplete information even though the electronics are functioning properly.
Note which segments or icons always fail; if the pattern is fixed, check the display, if it is intermittent, check the connection wiring.
Fault codes from Saunier Duval that this spare part resolves.
| Code | Fault | Diagnosis and solution |
|---|---|---|
| F13 | Main PCB fault | Yes — it is the direct code of the PCB. Check 230 V, fuse, connectors, and grounding; if it persists, replace the PCB. |
| F11 | No signal is reaching the main circuit | Possible — first rule out wiring and connectors to the PCB; if they are fine, it is usually the PCB. |
| F12 | No signal from the user interface | Normally not — it's usually the display or its cable, not this main PCB. |
| F18 | User interface fault | Normally not — it corresponds to the panel/display, not to this PCB. |
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Data sheet for the Saunier Duval S10470 PCB.
- Catalogue reference
- S10470
- Brand
- Saunier Duval
- Type of part
- PCBs (control boards)
- Units in stock
- 1 unit
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- Delivery time shown at checkout
- Return
- 14 days
Data read on the part and in the manufacturer's documentation
What we have not been able to verify does not appear here.
- voltage
- 220V
Manuals and technical documentation
Official documentation of the boiler, useful for locating the part and cross-referencing the fault codes.
- Saunier Duval S C 24 E Manual (PDF)Document © Saunier Duval, provided as a technical reference.