The Main PCB Saunier Duval Thematek C 24 EO BT, with reference S10470, is a control component that manages the ignition, burner modulation, pump, and safety features of the boiler. When this part fails, the boiler may not start, become locked, or exhibit erratic behavior. It is compatible with models such as C 24 E, C 25 E, F 24 E, and S F 24 E, among others in the Thematek range. A technician must confirm through diagnosis whether it needs to be replaced upon detecting issues in the boiler's operation, such as faults F11, F12, F13, or F18.

Catalogue reference
S10470
Warranty
1 year
VAT included Stock · 1 unit
Compatibility

Saunier Duval boilers compatible with reference S10470

PCB with reference S10470. 33 verified compatibilities: F 25 E and F 24 E.

Verified compatibility

Boiler modelFamilyVerification
Saunier Duval F 25 EThemaClassicVerified
Saunier Duval F 24 EThemaClassicVerified
Saunier Duval C 24 EThemaClassicVerified
Saunier Duval C 25 EThemaClassicVerified
Saunier Duval C AS 24 EThemaClassicVerified
Saunier Duval C AS 25 EThemaClassicVerified
Saunier Duval F AS 24 EThemaClassicVerified
Saunier Duval F AS 25 EThemaClassicVerified
Saunier Duval F AS 30 EThemaClassicVerified
Saunier Duval C 24 EThemafastVerified
Saunier Duval C 25 EThemafastVerified
Saunier Duval C 28 EThemafastVerified
Saunier Duval C 30 EThemafastVerified
Saunier Duval F 24 EThemafastVerified
Saunier Duval F 25 EThemafastVerified
Saunier Duval F 25 E H-MODThemafastVerified
Saunier Duval F 30 EThemafastVerified
Saunier Duval F 30 E H-MODThemafastVerified
Saunier Duval C 24 EThematekVerified
Saunier Duval C 24 EO BTThematekVerified
Saunier Duval F 24 EThematekVerified
Saunier Duval S C 24 EThematekVerified
Saunier Duval S F 24 EThematekVerified
Saunier Duval C 24 EAIsotwinVerified
Saunier Duval C 28 EAIsotwinVerified
Saunier Duval C 24 E ad04IsotwinVerified
Saunier Duval C 24 E de04IsotwinVerified
Saunier Duval F 24 EIsotwinVerified
Saunier Duval F 24 EAIsotwinVerified
Saunier Duval F 28 EAIsotwinVerified
Saunier Duval F 30 E H-MODIsofastVerified
Saunier Duval F 35 E H-MODIsofastVerified
Saunier Duval F 25 E STLThemaVerified

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if ref. S10470 is the part for your boiler

The part reference, model, and equipment revision must be verified against the manufacturer's documentation.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference S10470. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms that require diagnosis on the PCB S10470

The PCB controls the ignition, modulation, and safety features of the boiler. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The boiler does not turn on: there is no display, lights, or sound.

    Cause: If the PCB does not receive power, no component works.

    Check if the boiler has mains voltage and if the main switch is on before considering the PCB.

  • 02

    Different fault codes appear without repeating the same one.

    Cause: If the microprocessor or an input on the PCB fails intermittently, the alerts change with each attempt.

    Note the codes that appear; if they vary without relation to the operation of the boiler, it is more likely to be the PCB.

  • 03

    The thermostat or the control does not manage to activate the boiler.

    Cause: The commands from the control unit go through the PCB before reaching the burner or the pump; if the communication fails, the command is lost.

    Check that the remote control has new batteries and that the bus cable is properly connected before replacing the PCB.

  • 04

    The circulation pump does not start even though the boiler requests it.

    Cause: The PCB sends the command to the pump through one of its relays; if that relay fails, the pump does not activate.

    Use a multimeter to check if the pump is receiving power when the boiler should be turning it on; if it is not receiving anything, the command is not coming from the PCB.

Fault codes Saunier Duval that require diagnosis

CodeFaultTechnical checks
F13Main PCB faultYes — it is the direct code of the PCB. Check 230 V, fuse, connectors, and grounding; if it persists, replace the PCB.
F11No signal is reaching the main circuitPossible — first rule out wiring and connectors to the PCB; if they are fine, it is usually the PCB.
F12No signal from the user interfaceNormally not — it's usually the display or its cable, not this main PCB.
F18User interface faultNormally not — it corresponds to the panel/display, not to this PCB.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Data sheet for the Saunier Duval S10470 PCB.

Catalogue reference
S10470
Uniclima internal SKU
PETC24EBT
Brand
Saunier Duval
Type of part
PCBs (control boards)
Units in stock
1 unit
Status
Refurbished
Warranty
1 year
Shipping
Delivery time shown at checkout
Return
14 days

Part data and available documentation

Contrast the label codes, PCB, and revision with the installed part; they are not necessarily equivalent references.

Silkscreen marking in the photograph
SYMSI7.0
Frequently asked questions

Frequently asked questions about the PCB S10470

Does this PCB work for the Saunier Duval Themaclassic C24E in addition to the Thematek C24EO BT?
Yes, it is among the compatible models, along with Isofast F30E H-MOD, Isotwin C24EA/C28EA, Themaclassic F24E, Themafast C24E/F30E H-MOD, and Thematek C24E/F24E.