Saunier Duval ThemaClassic F25E PCB - Cod. 0310144400L12
Control PCB for Saunier Duval boilers from the ThemaClassic, Thema, ThemaFast, Thematek, Isofast, and Isotwin ranges. It is identified by the silkscreen code 0310144400L12 (SYMSI7.0 board). It includes a T630mA/250V protection fuse and two OMRON G5Q-1 relays. It is replaced when this board fails to properly control the boiler and the symptoms indicate the printed circuit, not another component.
VAT included
Consult via WhatsAppSaunier Duval boilers compatible with reference S10470
PCB with reference S10470. 33 verified compatibilities: F 25 E and F 24 E.
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Saunier Duval F 25 E | ThemaClassic | Contrasted |
| Saunier Duval F 24 E | ThemaClassic | Contrasted |
| Saunier Duval C 24 E | ThemaClassic | Contrasted |
| Saunier Duval C 25 E | ThemaClassic | Contrasted |
| Saunier Duval C AS 24 E | ThemaClassic | Contrasted |
| Saunier Duval C AS 25 E | ThemaClassic | Contrasted |
| Saunier Duval F AS 24 E | ThemaClassic | Contrasted |
| Saunier Duval F AS 25 E | ThemaClassic | Contrasted |
| Saunier Duval F AS 30 E | ThemaClassic | Contrasted |
| Saunier Duval C 24 E | Themafast | Contrasted |
| Saunier Duval C 25 E | Themafast | Contrasted |
| Saunier Duval C 28 E | Themafast | Contrasted |
| Saunier Duval C 30 E | Themafast | Contrasted |
| Saunier Duval F 24 E | Themafast | Contrasted |
| Saunier Duval F 25 E | Themafast | Contrasted |
| Saunier Duval F 25 E H-MOD | Themafast | Contrasted |
| Saunier Duval F 30 E | Themafast | Contrasted |
| Saunier Duval F 30 E H-MOD | Themafast | Contrasted |
| Saunier Duval C 24 E | Thematek | Contrasted |
| Saunier Duval C 24 EO BT | Thematek | Contrasted |
| Saunier Duval F 24 E | Thematek | Contrasted |
| Saunier Duval S C 24 E | Thematek | Contrasted |
| Saunier Duval S F 24 E | Thematek | Contrasted |
| Saunier Duval C 24 EA | Isotwin | Contrasted |
| Saunier Duval C 28 EA | Isotwin | Contrasted |
| Saunier Duval C 24 E ad04 | Isotwin | Contrasted |
| Saunier Duval C 24 E de04 | Isotwin | Contrasted |
| Saunier Duval F 24 E | Isotwin | Contrasted |
| Saunier Duval F 24 EA | Isotwin | Contrasted |
| Saunier Duval F 28 EA | Isotwin | Contrasted |
| Saunier Duval F 30 E H-MOD | Isofast | Contrasted |
| Saunier Duval F 35 E H-MOD | Isofast | Contrasted |
| Saunier Duval F 25 E STL | Thema | Contrasted |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if ref. S10470 is the part for your boiler
What determines it is not the boiler model, but the reference printed on the part you already have installed.
- Find the reference printed on the installed part and check whether it matches the catalogue reference S10470. If it is not visible, do not identify the part from its shape alone.
- Check the full boiler model on its data plate and look for it in the model associations on this page.
- Compare the connections and physical body with the original part before installation.
- If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Symptoms and faults that the PCB S10470 resolves
The PCB controls the ignition, modulation, and safety features of the boiler. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
The boiler does not start and no pilot light is lit on the panel.
Cause: The PCB has a protection fuse (T630mA/250V); if it blows, it cuts off all power even if the rest of the circuit is fine.
Visually check the fuse before purchasing the PCB: if it is blown, sometimes it is enough to replace it.
- 02
A relay click is heard, but the boiler does not respond to the heating or domestic hot water command.
Cause: The PCB has two OMRON G5Q-1 relays that switch the ignition; if one fails, the command does not reach the component that should be activated.
Check if the clicking sound corresponds to the circuit that is failing (heating or domestic hot water) to narrow down the diagnosis.
- 03
An error code appears on the display that does not change even after resetting the boiler.
Cause: The printed circuit board of this PCB manages all the sensors; an internal fault remains fixed until the board is replaced.
Note the exact code: in the ThemaClassic and Thema ranges, there are codes that indicate sensor or pressure switch, not the PCB.
- 04
The boiler operates intermittently, stopping and starting on its own without any apparent reason.
Cause: A relay or a circuit component degraded by use may fail sporadically before completely breaking down.
Note when it occurs (cold start, after several hours of use) before replacing the PCB.
Fault codes from Saunier Duval that this spare part resolves.
| Code | Fault | Diagnosis and solution |
|---|---|---|
| F13 | Main PCB fault | Yes — it is the direct code of the PCB. Check 230 V, fuse, connectors, and grounding; if it persists, replace the PCB. |
| F11 | No signal is reaching the main circuit | Possible — first rule out wiring and connectors to the PCB; if they are fine, it is usually the PCB. |
| F12 | No signal from the user interface | Normally not — it's usually the display or its cable, not this main PCB. |
| F18 | User interface fault | Normally not — it corresponds to the panel/display, not to this PCB. |
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Data sheet for the Saunier Duval S10470 PCB.
- Catalogue reference
- S10470
- Brand
- Saunier Duval
- Type of part
- PCBs (control boards)
- Units in stock
- 30 pcs
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- 1-2 business days
- Return
- 14 days
Data read on the part and in the manufacturer's documentation
What we have not been able to verify does not appear here.
- PCB name (silkscreened)
- SYMSI7.0
- Silkscreened code on the PCB
- 0310144400L12
- Label / batch code (with barcode)
- 4000140782 111-3872 / SFL 05/28 IND 6 S006D
- Protection fuse
- T630mA / 250V
- Relays
- OMRON G5Q-1 DC24V and G5Q-1A DC24V, contacts 5A 30VDC / 10A 250VAC (two units, made in China)
Manuals and technical documentation
Official documentation of the boiler, useful for locating the part and cross-referencing the fault codes.
- Saunier Duval S C 24 E Manual (PDF)Document © Saunier Duval, provided as a technical reference.