SYMSI7.0 PCB Saunier Duval Isofast/Isotwin/Thema Ref. S10470
The SYMSI7.0 PCB (control board) from Saunier Duval Isofast/Isotwin/Thema Ref. S10470 is the component that controls the ignition, burner modulation, and pump functions in the boiler. When it fails, the boiler may not start, lock out, or exhibit erratic behavior, which can manifest through faults such as F13, F11, F12, or F18. This board is compatible with models from the ThemaClassic, Themafast, Thematek, Isotwin, Isofast, and Thema ranges, among others. It is recommended to replace it when these symptoms or operational faults are detected.
VAT included
Consult via WhatsAppSaunier Duval boilers compatible with reference S10470
PCB with reference S10470. 33 verified compatibilities: F 25 E and F 24 E.
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Saunier Duval F 25 E | ThemaClassic | Contrasted |
| Saunier Duval F 24 E | ThemaClassic | Contrasted |
| Saunier Duval C 24 E | ThemaClassic | Contrasted |
| Saunier Duval C 25 E | ThemaClassic | Contrasted |
| Saunier Duval C AS 24 E | ThemaClassic | Contrasted |
| Saunier Duval C AS 25 E | ThemaClassic | Contrasted |
| Saunier Duval F AS 24 E | ThemaClassic | Contrasted |
| Saunier Duval F AS 25 E | ThemaClassic | Contrasted |
| Saunier Duval F AS 30 E | ThemaClassic | Contrasted |
| Saunier Duval C 24 E | Themafast | Contrasted |
| Saunier Duval C 25 E | Themafast | Contrasted |
| Saunier Duval C 28 E | Themafast | Contrasted |
| Saunier Duval C 30 E | Themafast | Contrasted |
| Saunier Duval F 24 E | Themafast | Contrasted |
| Saunier Duval F 25 E | Themafast | Contrasted |
| Saunier Duval F 25 E H-MOD | Themafast | Contrasted |
| Saunier Duval F 30 E | Themafast | Contrasted |
| Saunier Duval F 30 E H-MOD | Themafast | Contrasted |
| Saunier Duval C 24 E | Thematek | Contrasted |
| Saunier Duval C 24 EO BT | Thematek | Contrasted |
| Saunier Duval F 24 E | Thematek | Contrasted |
| Saunier Duval S C 24 E | Thematek | Contrasted |
| Saunier Duval S F 24 E | Thematek | Contrasted |
| Saunier Duval C 24 EA | Isotwin | Contrasted |
| Saunier Duval C 28 EA | Isotwin | Contrasted |
| Saunier Duval C 24 E ad04 | Isotwin | Contrasted |
| Saunier Duval C 24 E de04 | Isotwin | Contrasted |
| Saunier Duval F 24 E | Isotwin | Contrasted |
| Saunier Duval F 24 EA | Isotwin | Contrasted |
| Saunier Duval F 28 EA | Isotwin | Contrasted |
| Saunier Duval F 30 E H-MOD | Isofast | Contrasted |
| Saunier Duval F 35 E H-MOD | Isofast | Contrasted |
| Saunier Duval F 25 E STL | Thema | Contrasted |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if ref. S10470 is the part for your boiler
What determines it is not the boiler model, but the reference printed on the part you already have installed.
- Find the reference printed on the installed part and check whether it matches the catalogue reference S10470. If it is not visible, do not identify the part from its shape alone.
- Check the full boiler model on its data plate and look for it in the model associations on this page.
- Compare the connections and physical body with the original part before installation.
- If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Symptoms and faults that the PCB S10470 resolves
The PCB controls the ignition, modulation, and safety features of the boiler. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
The boiler does not ignite and shows no signs of life: no display, no startup noise, nothing.
Cause: The SYMSI7.0 PCB manages the ignition and safety of the unit; if the sequence does not start, the boiler will not operate.
Check that power is reaching the PCB and that the internal fuse is not blown before considering it faulty.
- 02
The boiler occasionally locks out, without a consistent repeating fault code.
Cause: The relays on the PCB can fail intermittently and cause lockouts that do not always display the same fault code.
Note if the lockout occurs at the same moment in the cycle (ignition, modulation, shutdown) before changing the PCB.
- 03
They have already said that 'it's electronics' but there is no clear fault or localized issue in another part.
Cause: If sensors, pressure switch, and gas valve have been ruled out separately and the behavior remains erratic, the control board is the component that manages everything else.
Before replacing it, check that the pressure switch, the NTC sensor, and the gas valve have been tested separately, each with its own test.
Fault codes from Saunier Duval that this spare part resolves.
| Code | Fault | Diagnosis and solution |
|---|---|---|
| F13 | Main PCB fault | Yes — it is the direct code of the PCB. Check 230 V, fuse, connectors, and grounding; if it persists, replace the PCB. |
| F11 | No signal is reaching the main circuit | Possible — first rule out wiring and connectors to the PCB; if they are fine, it is usually the PCB. |
| F12 | No signal from the user interface | Normally not — it's usually the display or its cable, not this main PCB. |
| F18 | User interface fault | Normally not — it corresponds to the panel/display, not to this PCB. |
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Data sheet for the Saunier Duval S10470 PCB.
- Catalogue reference
- S10470
- Brand
- Saunier Duval
- Type of part
- PCBs (control boards)
- Units in stock
- 1 unit
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- 1-2 business days
- Return
- 14 days
Data read on the part and in the manufacturer's documentation
What we have not been able to verify does not appear here.
- PCB model (silkscreened)
- SYMSI7.0
- PCB code (silkscreened)
- 0310144400L12
- Supply voltage
- 230V
- Output relays
- OMRON G5Q-1A DC24V, contact 5A/250VAC - 10A/250VAC (marking on the relay itself, not on the PCB)
- Batch/serial marking on white label
- 4000126600 104-0857, SFL 04/36, IND 3 (batch/serial marking of this unit, not a catalog reference)
Manuals and technical documentation
Official documentation of the boiler, useful for locating the part and cross-referencing the fault codes.
- Saunier Duval S C 24 E Manual (PDF)Document © Saunier Duval, provided as a technical reference.