Saunier Duval ThemaClassic F 25 E PCB - Ref. 104412-e
When you open the hot water tap, the PCB Saunier Duval ThemaClassic F 25 E - Ref. 104412-e is responsible for controlling the ignition and modulation of the burner, as well as the pump and safety features of the boiler. If this board fails, the boiler may not start, become locked, or behave erratically, displaying the fault code F5: Overheating. It is compatible with models such as ThemaClassic F 25 E and C 25 E, among others. It is recommended to replace it when you notice these symptoms to restore the operation of your system.
VAT included
Consult via WhatsAppSaunier Duval boilers compatible with reference S1062000
PCB with reference S1062000. Three confirmed compatibilities: ThemaClassic F 25 E and ThemaClassic C 25 E.
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Saunier Duval ThemaClassic F 25 E | ThemaClassic | Contrasted |
| Saunier Duval ThemaClassic C 25 E | ThemaClassic | Contrasted |
| Saunier Duval Isotwin F 28 EA | Isotwin | Contrasted |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if ref. S1062000 is the part for your boiler
What determines it is not the boiler model, but the reference printed on the part you already have installed.
- Find the reference printed on the installed part and check whether it matches the catalogue reference S1062000. If it is not visible, do not identify the part from its shape alone.
- Check the full boiler model on its data plate and look for it in the model associations on this page.
- Compare the connections and physical body with the original part before installation.
- If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Symptoms and faults that the PCB S1062000 resolves.
The PCB controls the ignition, modulation, and safety features of the boiler. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
The water comes out very hot sometimes and lukewarm at other times; the boiler does not maintain a stable temperature.
Cause: The PCB controls the modulation of the flame according to demand, and if it fails, the boiler operates in jumps instead of regulating.
First, check the temperature sensor and ensure that the heat exchanger is not scaled, as they can produce very similar symptoms.
- 02
The boiler is requesting heat, but neither the pump nor the fan are moving; everything remains still.
Cause: The PCB sends the start command to these components, and if that output is damaged, the command does not reach them even if the rest is functioning.
With the boiler turned off, manually check that the pump spins freely: if it is stuck, the problem is the pump, not the PCB.
- 03
The display shows an ignition fault even though the flame ignites properly.
Cause: The PCB interprets the ionization signal that confirms there is a flame, and if that reading fails, it shuts down the unit even if everything else is correct.
Check the ionization electrode and its cable first, as they often give the same warning without it being the PCB.
- 04
The boiler stops and restarts by itself several times before staying on, or it fails to do so.
Cause: The transformer or the relays on the PCB, if they fail, intermittently cut off the power to the ignition cycle.
Note how many attempts it makes and if it coincides with any noise or clicking on the PCB before replacing it.
Fault codes from Saunier Duval that this spare part resolves.
| Code | Fault | Diagnosis and solution |
|---|---|---|
| F5 | Overheating | The boiler stops for safety reasons when it detects overheating. This can happen if the PCB is not functioning properly and does not detect the correct temperature, so it would be advisable to replace it. |
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Data sheet for the Saunier Duval S1062000 PCB.
- Catalogue reference
- S1062000
- Brand
- Saunier Duval
- Type of part
- PCBs (control boards)
- Units in stock
- 1 unit
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- 1-2 business days
- Return
- 14 days
Data read on the part and in the manufacturer's documentation
What we have not been able to verify does not appear here.
- PCB code (Saunier Duval)
- 104412-e
- PCB code (engraved on control board)
- 356081200
- Standard
- 99/396 0.506.001(08)
- PCB inspection
- 1725-1T REV 3
- Supply voltage
- 230V
- Main PCB code (control chip)
- ST1389 CAO 4023
- Main chip
- HCTA07RD 011298 / AM3748MBT-154SP 9301QD
- Transformer (T28-0438)
- PRI 24V~50/60Hz (terminals 1-5), SEC 48V~0.05VA (terminals 8-10), TÜV CLASS E EN61558
- DIP switch configuration
- SW1 (6 positions)
Manuals and technical documentation