Saunier Duval Combitek F23E PCB Ref. 05728600
If your boiler does not start, locks out, or behaves erratically, a technical diagnosis must confirm if you need the Saunier Duval Combitek F23E PCB. This control board is responsible for managing the ignition, burner modulation, pump, and safety features of the boiler. When it fails, you may notice these issues in its operation. It is installed in models such as Combitek F23E and Combitek C23E, among other boilers in the range. A technician must confirm through diagnosis if it needs to be replaced upon detecting these symptoms to restore the operation of your boiler.
- Type of part
- PCBs (control boards)
- Status
- Refurbished
- Catalogue reference
- 05728600
- Warranty
- 1 year
Saunier Duval boilers compatible with reference 05728600
PCB with reference 05728600. Two confirmed compatibilities: Combitek F23E and Combitek C23E.
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Saunier Duval Combitek F23E | Combitek | Contrasted |
| Saunier Duval Combitek C23E | Combitek | Contrasted |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if ref. 05728600 is the part for your boiler
The part reference, model, and equipment revision must be verified against the manufacturer's documentation.
- Find the reference printed on the installed part and check whether it matches the catalogue reference 05728600. If it is not visible, do not identify the part from its shape alone.
- Check the full boiler model on its data plate and look for it in the model associations on this page.
- Compare the connections and physical body with the original part before installation.
- If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Symptoms that require diagnosis on the PCB 05728600
The PCB controls the ignition, modulation, and safety features of the boiler. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
The boiler does not ignite and shows no signs of life: no lights, no display, and no noise from the fan.
Cause: This PCB distributes power to the other components; if it fails, no current reaches anything.
Check the fuse on the PCB and verify that 230V is reaching its input before replacing it.
- 02
The boiler ignites but turns off by itself after a few minutes, without a clear pattern.
Cause: An intermittent fault in the PCB (cold solder joint or component overheating) erratically cuts off the supply.
Note if the cut coincides with the use of domestic hot water or heating: it helps to distinguish a fault in the PCB from one in the associated sensor.
- 03
The display shows a different fault code each time, with no clear relation to what is actually happening.
Cause: The error management of the PCB is damaged and generates incorrect readings from the sensors.
Note the codes that appear and compare them with the manual before discarding the PCB; a repeated code usually indicates another component.
- 04
The boiler does not respond to temperature changes from the control or the thermostat.
Cause: The circuit that receives the command from the thermostat and activates the burner is not working.
Check that the thermostat has batteries and that its cable is properly connected to the PCB before replacing it.
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Data sheet for the Saunier Duval 05728600 PCB.
- Catalogue reference
- 05728600
- Uniclima internal SKU
- PLCCBTK
- Brand
- Saunier Duval
- Type of part
- PCBs (control boards)
- Units in stock
- 5 units
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- Delivery time shown at checkout
- Return
- 14 days
Part data and available documentation
Contrast the label codes, PCB, and revision with the installed part; they are not necessarily equivalent references.
- PCB silk-screened code
- ST13B
- Silkscreened secondary code
- TP9644E / EEV9SZ1FT
- Relay code
- 23939-A (tentative reading)
- Main IC label text
- CHANTIER HCTA 077C
Manuals and technical documentation
Official documentation of the boiler, useful for locating the part and cross-referencing the fault codes.
- Saunier Duval Combitek F23E Manual (PDF) Document © Saunier Duval, provided as a technical reference.