Saunier Duval Themaplus C 23 E PCB
The Saunier Duval Themaplus C 23 E PCB is a component that controls the ignition, burner modulation, pump, and safety features of the boiler. When it fails, the boiler does not start, locks out, or exhibits erratic behavior. This board is compatible with several models from the Thema and Themaplus ranges, such as the C 23 E and F 23 E, among others. It is recommended to replace it if you experience starting issues or unstable operation.
VAT included
Consult via WhatsAppSaunier Duval boilers compatible with reference 05741000
PCB with reference 05741000. Eight confirmed compatibilities: C 23 E and F 23 E.
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Saunier Duval C 23 E | Thema | Contrasted |
| Saunier Duval F 23 E | Thema | Contrasted |
| Saunier Duval C AS 23 E | Thema | Contrasted |
| Saunier Duval F AS 23 E | Thema | Contrasted |
| Saunier Duval C 23 E | Themaplus | Contrasted |
| Saunier Duval F 23 E | Themaplus | Contrasted |
| Saunier Duval C 23 E | Combitek | Contrasted |
| Saunier Duval F 23 E | Combitek | Contrasted |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if ref. 05741000 is the part for your boiler
What determines it is not the boiler model, but the reference printed on the part you already have installed.
- Find the reference printed on the installed part and check whether it matches the catalogue reference 05741000. If it is not visible, do not identify the part from its shape alone.
- Check the full boiler model on its data plate and look for it in the model associations on this page.
- Compare the connections and physical body with the original part before installation.
- If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Symptoms and faults that the PCB 05741000 resolves.
The PCB controls the ignition, modulation, and safety features of the boiler. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
The boiler turns off by itself intermittently, without a clear pattern.
Cause: A contact or soldering fault on the PCB can intermittently cut off the power supply.
With the boiler running, carefully move the connectors on the PCB to see if the cut occurs again when touching any cable.
- 02
The boiler does not ignite and there are no LEDs or indicators active on the panel.
Cause: If the transformer on the PCB does not deliver the necessary 24 V, no element of the panel can be activated.
Measure with a multimeter if there is voltage at the output of the transformer on the PCB before declaring it faulty.
- 03
The room thermostat is calling for heat, but the boiler is not responding.
Cause: The PCB receives the signal from the thermostat and commands the start; if the input circuit fails, the demand does not activate anything.
Check that the thermostat is working by directly bridging its terminals on the PCB before replacing it.
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Data sheet for the Saunier Duval 05741000 PCB.
- Catalogue reference
- 05741000
- Brand
- Saunier Duval
- Type of part
- PCBs (control boards)
- Units in stock
- 5 units
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- 1-2 business days
- Return
- 14 days
Data read on the part and in the manufacturer's documentation
What we have not been able to verify does not appear here.
- Manufacturer
- Saunier Duval
- PCB code
- ST1488
- PCB certification code
- 1293 94V-0 fuba T
- Main chip
- ART7488RR-3703V
- Transformer - primary
- 24 V 50/60 Hz
- Transformer - secondary
- A8V 0.05VA
- Relay (code)
- 23535-A, 24V 50/60Hz
- White relay - manufacturer
- Schrack, marking D272 ECD41-A?MF A422 (relay manufacturer, not the PCB)
- The only manufacturer other than Saunier Duval that is mentioned on the entire PCB is Schrack, and it is the manufacturer of the white relay, not of the complete board.
Manuals and technical documentation
Official documentation of the boiler, useful for locating the part and cross-referencing the fault codes.
- Saunier Duval C AS 23 E Manual (PDF)Document © Saunier Duval, provided as a technical reference.