SIT PCB Saunier Duval Thema C 23 E Ref. ABC536

SIT PCB Saunier Duval Thema C 23 E Ref. ABC536

Stock · 2 units

PCB for Saunier Duval boilers from the Thema/Combitek C-F 23/24 E series. The actual manufacturer of the component is SIT, different from the boiler brand; the silkscreen shows the code ABC536 along with the transformer data: primary 24V 50/60Hz (6-10) and secondary 48V 0.05VA ta70/B. The codes ST1485b CAO 4914 and 0134 printed next to the previous one seem to be manufacturing batch marks, not commercial references.

VAT included

Compatibility

Saunier Duval boilers compatible with reference 05741000

PCB with reference 05741000. Eight confirmed compatibilities: C 23 E and F 23 E.

Proven compatibility

Boiler modelFamilyVerification
Saunier Duval C 23 EThemaContrasted
Saunier Duval F 23 EThemaContrasted
Saunier Duval C AS 23 EThemaContrasted
Saunier Duval F AS 23 EThemaContrasted
Saunier Duval C 23 EThemaplusContrasted
Saunier Duval F 23 EThemaplusContrasted
Saunier Duval C 23 ECombitekContrasted
Saunier Duval F 23 ECombitekContrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if ref. 05741000 is the part for your boiler

What determines it is not the boiler model, but the reference printed on the part you already have installed.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference 05741000. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms and faults that the PCB 05741000 resolves.

The PCB controls the ignition, modulation, and safety features of the boiler. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The boiler does not ignite, you can't even hear the spark attempt.

    Cause: The PCB sends the ignition command to the gas valve and the electrode; without that command, there is no ignition attempt.

    Check that the ignition electrode and its cable are in good condition before assuming that the PCB is to blame.

  • 02

    The flame rises and falls on its own, without requesting more or less heat.

    Cause: Erratic modulation is often caused by the part of the PCB that controls the gas valve.

    Check the gas inlet pressure and the condition of the filter before considering that the PCB is responsible.

  • 03

    The boiler runs for a few minutes and then locks out on its own.

    Cause: The PCB continuously monitors safety parameters and shuts down the equipment if it detects anything out of range.

    Note how long it takes to block; if it is always the same time, it will help you identify in which phase it fails.

  • 04

    The boiler indicator is flashing but it doesn't match any code in the manual.

    Cause: An irregular blinking may be caused by a fault in the electronics that manage that signaling.

    Count the number of blinks and the pauses between them carefully; sometimes the code does exist but can be misread.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Data sheet for the Saunier Duval 05741000 PCB.

Catalogue reference
05741000
Brand
Saunier Duval
Type of part
PCBs (control boards)
Units in stock
2 units
Status
Refurbished
Warranty
1 year
Shipping
1-2 business days
Return
14 days

Data read on the part and in the manufacturer's documentation

What we have not been able to verify does not appear here.

Code printed on PCB
ABC536
Manufacturer printed on PCB
SIT
Primary transformer
24V 50/60Hz (6-10)
Secondary transformer
48V 0.05VA ta70/B
Before purchasing
  • The component manufacturer is SIT, different from Saunier Duval, the boiler brand.
  • The codes 'ST1485b CAO 4914' and '0134' printed on the PCB appear to be manufacturing batch marks, not a commercial reference; do not use them to order the part.
Documentation

Manuals and technical documentation

Official documentation of the boiler, useful for locating the part and cross-referencing the fault codes.

Frequently Asked Questions

Frequently asked questions about the PCB 05741000

Does this PCB work for my Saunier Duval Thema C 24 E?
Yes, it is among the compatible models listed for this PCB.
Is the PCB of the Thema C 23 E manufactured by Saunier Duval or a third party?
The component is silk-screened with the manufacturer SIT; Saunier Duval is the brand of the boiler, not the component.
What transformer is installed on the SIT PCB of the Thema C 23 E?
Primary 24V 50/60Hz (6-10) and secondary 48V 0.05VA ta70/B.

Spare parts related to Saunier Duval Thema

Delivery 1–2 daysworking days, mainland Spain
1-year warrantyreviewed and tested
14-day returnuninstalled parts
Technical supportwe verify your model
SIT PCB Saunier Duval Thema C 23 E Ref. ABC536