Saunier Duval Thema / Combitek PCB - ST1399 CAD 4093

Saunier Duval Thema / Combitek PCB - ST1399 CAD 4093

Stock · 1 unit

Saunier Duval PCB, identified by the logo and the text 'SAUNIER DUVAL' printed next to the code ST1399 CAD 4093. It includes a transformer with code 22S2S-A, several potentiometers (P1F, P2, P3, P4), and a configuration dip-switch. Compatible with the Combitek, Thema, and Themaplus ranges. The reference 05741000 currently used in the catalog does not match the code read on the board.

VAT included

Compatibility

Saunier Duval boilers compatible with reference 05741000

PCB with reference 05741000. Eight confirmed compatibilities: C 23 E and F 23 E.

Proven compatibility

Boiler modelFamilyVerification
Saunier Duval C 23 EThemaContrasted
Saunier Duval F 23 EThemaContrasted
Saunier Duval C AS 23 EThemaContrasted
Saunier Duval F AS 23 EThemaContrasted
Saunier Duval C 23 EThemaplusContrasted
Saunier Duval F 23 EThemaplusContrasted
Saunier Duval C 23 ECombitekContrasted
Saunier Duval F 23 ECombitekContrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if ref. 05741000 is the part for your boiler

What determines it is not the boiler model, but the reference printed on the part you already have installed.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference 05741000. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms and faults that the PCB 05741000 resolves.

The PCB controls the ignition, modulation, and safety features of the boiler. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The boiler ignites but the flame does not modulate: it always stays at maximum or minimum.

    Cause: The PCB controls the modulation of the gas valve; if it fails, it loses control of the flame.

    Check that the ionization electrode is clean and properly positioned.

  • 02

    The boiler loses its configuration or settings every time there is a power outage.

    Cause: A fault in the PCB can cause it not to retain the configured parameters.

    Note if the problem always coincides with a power supply interruption.

  • 03

    The boiler does not ignite and there are no visible symptoms, no relay noise or LED.

    Cause: Without proper power supply from the PCB, no component works.

    Measure with a multimeter if current is reaching the input of the PCB.

  • 04

    The temperature controls of the boiler do not change anything in the actual operation.

    Cause: The adjustment potentiometers are on the PCB; if they degrade, the boiler ignores the changes.

    Turn the controls and check if the display or the behavior of the boiler responds.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Data sheet for the Saunier Duval 05741000 PCB.

Catalogue reference
05741000
Brand
Saunier Duval
Type of part
PCBs (control boards)
Units in stock
1 unit
Status
Refurbished
Warranty
1 year
Shipping
1-2 business days
Return
14 days

Data read on the part and in the manufacturer's documentation

What we have not been able to verify does not appear here.

Brand printed on the PCB
SAUNIER DUVAL (hand logo)
PCB code
ST1399 CAD 4093
Transformer code
22S2S-A
Documentation

Manuals and technical documentation

Official documentation of the boiler, useful for locating the part and cross-referencing the fault codes.

Frequently Asked Questions

Frequently asked questions about the PCB 05741000

Does this ST1399 CAD 4093 PCB have the Saunier Duval brand printed on it?
Yes, the logo and the text 'SAUNIER DUVAL' are printed directly on the PCB, next to the code ST1399 CAD 4093.
Is this ST1399 CAD 4093 PCB compatible with the Thema C AS 23 E?
Yes, it is listed for Combitek C/F 23 E, Thema C 19 E, C 23 E, C AS 23 E, F 23 E, F AS 23 E, and Themaplus C/F 23 E.
What transformer and potentiometers does the ST1399 CAD 4093 PCB use?
The transformer is marked 22S2S-A, and there are potentiometers identified as P1F, P2, P3, and P4 with a configuration dip-switch.

Spare parts related to Saunier Duval Thema

Delivery 1–2 daysworking days, mainland Spain
1-year warrantyreviewed and tested
14-day returnuninstalled parts
Technical supportwe verify your model
Saunier Duval Thema / Combitek PCB - ST1399 CAD 4093