Saunier Duval Isofast F 28 E1 PCB (control board)

Saunier Duval Isofast F 28 E1 PCB (control board)

Stock · 1 unit

When you open the tap or turn on the heating, the Saunier Duval Isofast F 28 E1 PCB (reference S1047000) is responsible for controlling the ignition, the modulation of the burner, and the boiler pump. If it fails, you may notice that the boiler does not start, gets locked, or exhibits erratic behavior, displaying fault codes such as 13 or 20. This board is compatible with several models from the Isofast and Isomax ranges, including the F 28 E1 and C 28 E1, among others. It is recommended to replace it when the mentioned symptoms occur or a communication fault is indicated.

VAT included

Compatibility

Saunier Duval boilers compatible with reference S1019000

PCB with reference S1019000. 11 verified compatibilities: C 28 E1 and C 28 E1 NOX.

Proven compatibility

Boiler modelFamilyVerification
Saunier Duval C 28 E1IsofastContrasted
Saunier Duval C 28 E1 NOxIsofastContrasted
Saunier Duval C 35 E1IsofastContrasted
Saunier Duval F 28 E1IsofastContrasted
Saunier Duval F 35 E1IsofastContrasted
Saunier Duval C 28 E2IsomaxContrasted
Saunier Duval C 28 E204IsomaxContrasted
Saunier Duval C 28 E205IsomaxContrasted
Saunier Duval F 28 E2IsomaxContrasted
Saunier Duval F 28 E204IsomaxContrasted
Saunier Duval F 28 E205IsomaxContrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if ref. S1019000 is the part for your boiler

What determines it is not the boiler model, but the reference printed on the part you already have installed.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference S1019000. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms and faults that the PCB S1019000 resolves.

The PCB controls the ignition, modulation, and safety features of the boiler. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The boiler does not ignite and no LED is active on the PCB.

    Cause: The PCB is not receiving power, often due to a blown internal fuse.

    Measure the continuity of the 125 mA fuse on the PCB; if it is blown, it is very likely to be the problem.

  • 02

    The display or the control does not start even though the boiler has power at the main input.

    Cause: The PCB does not distribute the current to the rest of the control circuit.

    Measure the output of the transformer on the PCB before deciding to replace it.

  • 03

    The boiler starts normally but loses the time or the programming.

    Cause: The PCB does not consistently retain the configuration memory.

    Reprogram and monitor if it loses connection again within a few hours before replacing the PCB.

  • 04

    A different fault occurs every few days, with no clear pattern.

    Cause: An intermittent fault in the PCB causes variable errors in each ignition cycle.

    Keep a record of the codes that appear; it will help you differentiate between a PCB fault and one related to a sensor or pressure switch that repeats.

Fault codes from Saunier Duval that this spare part resolves.

CodeFaultDiagnosis and solution
13Main printed circuit board fault.The main PCB (S1019000) does not pass the internal self-diagnosis; this is usually due to an electronics/EEPROM fault or the PCB not generating its internal voltages. Check the 230 V input, fuse, and low voltages (5/15/24 V) on the PCB; if these are correct and the wiring is OK, replace the PCB.
20Communication fault between the user interface and the main PCB.Communication channel/ebus fault on the main board, incompatibility between interface and PCB or defective connection/harness. Check the interface power supply from the board, connectors/harness and test with a known interface; if it persists, the cause is the PCB.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Data sheet for the Saunier Duval S1019000 PCB.

Catalogue reference
S1019000
Brand
Saunier Duval
Type of part
PCBs (control boards)
Units in stock
1 unit
Status
Refurbished
Warranty
1 year
Shipping
1-2 business days
Return
14 days

Data read on the part and in the manufacturer's documentation

What we have not been able to verify does not appear here.

Fuse
125 mA T, 250V
Transformer
Myrra (red, legible logo on the PCB)
Frequently Asked Questions

Frequently asked questions about the PCB S1019000

What fuse does the PCB of the Isofast F 28 E1 use?
A 125 mA T fuse at 250V, according to what is written on the PCB.
Does this PCB work for an Isofast C 35 E1 in addition to the F 28 E1?
Yes, Isofast C 35 E1 is on the list of compatible boilers, along with Isofast C 28 E1, F 35 E1, and Isomax C 28 E2 and F 28 E2.
What transformer is installed on the PCB of the Isofast F 28 E1?
A red transformer from the brand Myrra, visible on the PCB.

Spare parts related to Saunier Duval Isomax

Delivery 1–2 daysworking days, mainland Spain
1-year warrantyreviewed and tested
14-day returnuninstalled parts
Technical supportwe verify your model
Saunier Duval Isofast F 28 E1 PCB (control board)