Multifunctional PCB Sung Wei for Saunier Duval Isofast F30E H-MOD Ref. S10470 is a component that controls the ignition, burner modulation, pump, and safety features of the boiler. When it malfunctions, it can cause the boiler not to start, to lock out, or to operate erratically, displaying fault codes such as F13, F11, F12, or F18. This PCB is compatible with models from the ThemaClassic, Themafast, Thematek, Isotwin, and Isofast ranges, among others. A technician must confirm through diagnosis whether it needs to be replaced when these symptoms or operational errors are detected.

Catalogue reference
S10470
Warranty
1 year
VAT included Stock · 1 unit
Compatibility

Saunier Duval boilers compatible with reference S10470

PCB with reference S10470. 33 verified compatibilities: F 25 E and F 24 E.

Proven compatibility

Boiler modelFamilyVerification
Saunier Duval F 25 EThemaClassicContrasted
Saunier Duval F 24 EThemaClassicContrasted
Saunier Duval C 24 EThemaClassicContrasted
Saunier Duval C 25 EThemaClassicContrasted
Saunier Duval C AS 24 EThemaClassicContrasted
Saunier Duval C AS 25 EThemaClassicContrasted
Saunier Duval F AS 24 EThemaClassicContrasted
Saunier Duval F AS 25 EThemaClassicContrasted
Saunier Duval F AS 30 EThemaClassicContrasted
Saunier Duval C 24 EThemafastContrasted
Saunier Duval C 25 EThemafastContrasted
Saunier Duval C 28 EThemafastContrasted
Saunier Duval C 30 EThemafastContrasted
Saunier Duval F 24 EThemafastContrasted
Saunier Duval F 25 EThemafastContrasted
Saunier Duval F 25 E H-MODThemafastContrasted
Saunier Duval F 30 EThemafastContrasted
Saunier Duval F 30 E H-MODThemafastContrasted
Saunier Duval C 24 EThematekContrasted
Saunier Duval C 24 EO BTThematekContrasted
Saunier Duval F 24 EThematekContrasted
Saunier Duval S C 24 EThematekContrasted
Saunier Duval S F 24 EThematekContrasted
Saunier Duval C 24 EAIsotwinContrasted
Saunier Duval C 28 EAIsotwinContrasted
Saunier Duval C 24 E ad04IsotwinContrasted
Saunier Duval C 24 E de04IsotwinContrasted
Saunier Duval F 24 EIsotwinContrasted
Saunier Duval F 24 EAIsotwinContrasted
Saunier Duval F 28 EAIsotwinContrasted
Saunier Duval F 30 E H-MODIsofastContrasted
Saunier Duval F 35 E H-MODIsofastContrasted
Saunier Duval F 25 E STLThemaContrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if ref. S10470 is the part for your boiler

The part reference, model, and equipment revision must be verified against the manufacturer's documentation.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference S10470. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms that require diagnosis on the PCB S10470

The PCB controls the ignition, modulation, and safety features of the boiler. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The boiler does not turn on or show any signs of life, not even the indicator on the panel lights up.

    Cause: The multifunction PCB manages the complete startup of the unit; if it does not receive power or there is a fault in the control circuit, the boiler does not respond.

    Check that 230V is reaching the PCB and that the internal fuse is not blown before replacing it.

  • 02

    The control or thermostat is unable to start the boiler even though it is requesting heat.

    Cause: The PCB receives the demand signal and activates the other components; if the microcontroller does not process the signal, the unit does not respond.

    Check the connection of the thermostat or control cable to the PCB and make sure there are no loose or oxidized terminals.

  • 03

    The boiler displays a fault code that doesn't match any actual gas, water, or draft fault.

    Cause: An internal fault in the PCB can generate erratic or repetitive fault codes even if the rest of the installation is correct.

    Cross-check the code with the manual of the model and rule out pressure issues, ignition and sensors before declaring the PCB faulty.

  • 04

    The boiler shuts off by itself in the middle of operation and needs to be manually reset.

    Cause: A fault in the internal management of the PCB can cause spontaneous resets without any external cause.

    Note the time and the phase in which the cut occurs to rule out an electrical supply problem in the home.

Fault codes Saunier Duval that require diagnosis

CodeFaultTechnical checks
F13Main PCB faultYes — it is the direct code of the PCB. Check 230 V, fuse, connectors, and grounding; if it persists, replace the PCB.
F11No signal is reaching the main circuitPossible — first rule out wiring and connectors to the PCB; if they are fine, it is usually the PCB.
F12No signal from the user interfaceNormally not — it's usually the display or its cable, not this main PCB.
F18User interface faultNormally not — it corresponds to the panel/display, not to this PCB.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Data sheet for the Saunier Duval S10470 PCB.

Catalogue reference
S10470
Uniclima internal SKU
CETF25EMOD
Brand
Saunier Duval
Type of part
PCBs (control boards)
Units in stock
1 unit
Status
Refurbished
Warranty
1 year
Shipping
Delivery time shown at checkout
Return
14 days

Part data and available documentation

Contrast the label codes, PCB, and revision with the installed part; they are not necessarily equivalent references.

Component manufacturer
Sung Wei
Screen printing
SYMSI7.0 | SUNG WEI 06V0-A
Documentation

Manuals and technical documentation

Official documentation of the boiler, useful for locating the part and cross-referencing the fault codes.

Frequently Asked Questions

Frequently asked questions about the PCB S10470

Who manufactures this multifunction PCB for the Saunier Duval Isofast F30E H-MOD?
The component has the Sung Wei seal (SYMSI7.0 / SUNG WEI 06V0-A) printed on the PCB.
Is this Sung Wei PCB Ref. S10470 suitable for a Saunier Duval Thematek C24E?
Yes, the Thematek C24E is on the list of models compatible with this PCB.
What fault in the Saunier Duval Themafast F30E H-MOD does this multifunction PCB resolve?
It should be checked when the PCB stops managing the operation of the boiler correctly. Replacement requires a technical diagnosis.