Sung Wei Multifunction PCB for Saunier Duval Isofast F30E H-MOD Ref. S10470
Multifunctional PCB Sung Wei for Saunier Duval Isofast F30E H-MOD Ref. S10470 is a component that controls the ignition, burner modulation, pump, and safety features of the boiler. When it malfunctions, it can cause the boiler not to start, to lock out, or to operate erratically, displaying fault codes such as F13, F11, F12, or F18. This PCB is compatible with models from the ThemaClassic, Themafast, Thematek, Isotwin, and Isofast ranges, among others. A technician must confirm through diagnosis whether it needs to be replaced when these symptoms or operational errors are detected.
- Type of part
- PCBs (control boards)
- Status
- Refurbished
- Catalogue reference
- S10470
- Warranty
- 1 year
Saunier Duval boilers compatible with reference S10470
PCB with reference S10470. 33 verified compatibilities: F 25 E and F 24 E.
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Saunier Duval F 25 E | ThemaClassic | Contrasted |
| Saunier Duval F 24 E | ThemaClassic | Contrasted |
| Saunier Duval C 24 E | ThemaClassic | Contrasted |
| Saunier Duval C 25 E | ThemaClassic | Contrasted |
| Saunier Duval C AS 24 E | ThemaClassic | Contrasted |
| Saunier Duval C AS 25 E | ThemaClassic | Contrasted |
| Saunier Duval F AS 24 E | ThemaClassic | Contrasted |
| Saunier Duval F AS 25 E | ThemaClassic | Contrasted |
| Saunier Duval F AS 30 E | ThemaClassic | Contrasted |
| Saunier Duval C 24 E | Themafast | Contrasted |
| Saunier Duval C 25 E | Themafast | Contrasted |
| Saunier Duval C 28 E | Themafast | Contrasted |
| Saunier Duval C 30 E | Themafast | Contrasted |
| Saunier Duval F 24 E | Themafast | Contrasted |
| Saunier Duval F 25 E | Themafast | Contrasted |
| Saunier Duval F 25 E H-MOD | Themafast | Contrasted |
| Saunier Duval F 30 E | Themafast | Contrasted |
| Saunier Duval F 30 E H-MOD | Themafast | Contrasted |
| Saunier Duval C 24 E | Thematek | Contrasted |
| Saunier Duval C 24 EO BT | Thematek | Contrasted |
| Saunier Duval F 24 E | Thematek | Contrasted |
| Saunier Duval S C 24 E | Thematek | Contrasted |
| Saunier Duval S F 24 E | Thematek | Contrasted |
| Saunier Duval C 24 EA | Isotwin | Contrasted |
| Saunier Duval C 28 EA | Isotwin | Contrasted |
| Saunier Duval C 24 E ad04 | Isotwin | Contrasted |
| Saunier Duval C 24 E de04 | Isotwin | Contrasted |
| Saunier Duval F 24 E | Isotwin | Contrasted |
| Saunier Duval F 24 EA | Isotwin | Contrasted |
| Saunier Duval F 28 EA | Isotwin | Contrasted |
| Saunier Duval F 30 E H-MOD | Isofast | Contrasted |
| Saunier Duval F 35 E H-MOD | Isofast | Contrasted |
| Saunier Duval F 25 E STL | Thema | Contrasted |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if ref. S10470 is the part for your boiler
The part reference, model, and equipment revision must be verified against the manufacturer's documentation.
- Find the reference printed on the installed part and check whether it matches the catalogue reference S10470. If it is not visible, do not identify the part from its shape alone.
- Check the full boiler model on its data plate and look for it in the model associations on this page.
- Compare the connections and physical body with the original part before installation.
- If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Symptoms that require diagnosis on the PCB S10470
The PCB controls the ignition, modulation, and safety features of the boiler. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
The boiler does not turn on or show any signs of life, not even the indicator on the panel lights up.
Cause: The multifunction PCB manages the complete startup of the unit; if it does not receive power or there is a fault in the control circuit, the boiler does not respond.
Check that 230V is reaching the PCB and that the internal fuse is not blown before replacing it.
- 02
The control or thermostat is unable to start the boiler even though it is requesting heat.
Cause: The PCB receives the demand signal and activates the other components; if the microcontroller does not process the signal, the unit does not respond.
Check the connection of the thermostat or control cable to the PCB and make sure there are no loose or oxidized terminals.
- 03
The boiler displays a fault code that doesn't match any actual gas, water, or draft fault.
Cause: An internal fault in the PCB can generate erratic or repetitive fault codes even if the rest of the installation is correct.
Cross-check the code with the manual of the model and rule out pressure issues, ignition and sensors before declaring the PCB faulty.
- 04
The boiler shuts off by itself in the middle of operation and needs to be manually reset.
Cause: A fault in the internal management of the PCB can cause spontaneous resets without any external cause.
Note the time and the phase in which the cut occurs to rule out an electrical supply problem in the home.
Fault codes Saunier Duval that require diagnosis
| Code | Fault | Technical checks |
|---|---|---|
| F13 | Main PCB fault | Yes — it is the direct code of the PCB. Check 230 V, fuse, connectors, and grounding; if it persists, replace the PCB. |
| F11 | No signal is reaching the main circuit | Possible — first rule out wiring and connectors to the PCB; if they are fine, it is usually the PCB. |
| F12 | No signal from the user interface | Normally not — it's usually the display or its cable, not this main PCB. |
| F18 | User interface fault | Normally not — it corresponds to the panel/display, not to this PCB. |
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Data sheet for the Saunier Duval S10470 PCB.
- Catalogue reference
- S10470
- Uniclima internal SKU
- CETF25EMOD
- Brand
- Saunier Duval
- Type of part
- PCBs (control boards)
- Units in stock
- 1 unit
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- Delivery time shown at checkout
- Return
- 14 days
Part data and available documentation
Contrast the label codes, PCB, and revision with the installed part; they are not necessarily equivalent references.
- Component manufacturer
- Sung Wei
- Screen printing
- SYMSI7.0 | SUNG WEI 06V0-A
Manuals and technical documentation
Official documentation of the boiler, useful for locating the part and cross-referencing the fault codes.
- Saunier Duval F 35 E H-MOD Manual (PDF) Document © Saunier Duval, provided as a technical reference.