Main PCB for Themaclassic F AS 24 E and Compatible Models
The main PCB controls the ignition, burner modulation, pump, and safety features of the Baxi Roca Themaclassic F AS 24 E boiler and compatible models. If it malfunctions, the boiler may fail to start, lock out, or operate erratically, displaying fault codes such as F13, F11, F12, or F18. This part is compatible with several models from the ThemaClassic, Themafast, Thematek, Isotwin, Isofast, and Thema ranges. It is recommended to replace it when these symptoms or errors are detected.
VAT included
Consult via WhatsAppSaunier Duval boilers compatible with reference S10470
PCB with reference S10470. 33 verified compatibilities: F 25 E and F 24 E.
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Saunier Duval F 25 E | ThemaClassic | Contrasted |
| Saunier Duval F 24 E | ThemaClassic | Contrasted |
| Saunier Duval C 24 E | ThemaClassic | Contrasted |
| Saunier Duval C 25 E | ThemaClassic | Contrasted |
| Saunier Duval C AS 24 E | ThemaClassic | Contrasted |
| Saunier Duval C AS 25 E | ThemaClassic | Contrasted |
| Saunier Duval F AS 24 E | ThemaClassic | Contrasted |
| Saunier Duval F AS 25 E | ThemaClassic | Contrasted |
| Saunier Duval F AS 30 E | ThemaClassic | Contrasted |
| Saunier Duval C 24 E | Themafast | Contrasted |
| Saunier Duval C 25 E | Themafast | Contrasted |
| Saunier Duval C 28 E | Themafast | Contrasted |
| Saunier Duval C 30 E | Themafast | Contrasted |
| Saunier Duval F 24 E | Themafast | Contrasted |
| Saunier Duval F 25 E | Themafast | Contrasted |
| Saunier Duval F 25 E H-MOD | Themafast | Contrasted |
| Saunier Duval F 30 E | Themafast | Contrasted |
| Saunier Duval F 30 E H-MOD | Themafast | Contrasted |
| Saunier Duval C 24 E | Thematek | Contrasted |
| Saunier Duval C 24 EO BT | Thematek | Contrasted |
| Saunier Duval F 24 E | Thematek | Contrasted |
| Saunier Duval S C 24 E | Thematek | Contrasted |
| Saunier Duval S F 24 E | Thematek | Contrasted |
| Saunier Duval C 24 EA | Isotwin | Contrasted |
| Saunier Duval C 28 EA | Isotwin | Contrasted |
| Saunier Duval C 24 E ad04 | Isotwin | Contrasted |
| Saunier Duval C 24 E de04 | Isotwin | Contrasted |
| Saunier Duval F 24 E | Isotwin | Contrasted |
| Saunier Duval F 24 EA | Isotwin | Contrasted |
| Saunier Duval F 28 EA | Isotwin | Contrasted |
| Saunier Duval F 30 E H-MOD | Isofast | Contrasted |
| Saunier Duval F 35 E H-MOD | Isofast | Contrasted |
| Saunier Duval F 25 E STL | Thema | Contrasted |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if ref. S10470 is the part for your boiler
What determines it is not the boiler model, but the reference printed on the part you already have installed.
- Find the reference printed on the installed part and check whether it matches the catalogue reference S10470. If it is not visible, do not identify the part from its shape alone.
- Check the full boiler model on its data plate and look for it in the model associations on this page.
- Compare the connections and physical body with the original part before installation.
- If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Symptoms and faults that the PCB S10470 resolves
The PCB controls the ignition, modulation, and safety features of the boiler. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
The boiler does not light up any indicator, it is completely off even though there is power at the outlet.
Cause: The main PCB manages all the power supply and control of the boiler, so its failure leaves everything unresponsive.
Before replacing it, check the fuse of the PCB and the main circuit breaker; they are the most common cause of this symptom and cost nothing to check.
- 02
The control works but the boiler does not execute the command: it neither ignites the burner nor moves the pump.
Cause: The microcontroller on the main PCB receives the request but does not activate the startup sequence.
Perform a full reset by cutting the power for one minute and check that the PCB connectors are not loose or corroded.
- 03
A new, unusual fault code appears, or it changes every time an attempt is made to reset the boiler.
Cause: The damaged control electronics cause incorrect readings from the sensors, generating fault codes that do not reflect the actual problem.
Write down the exact code and check it in the manual before deciding: it may point to a sensor and not to the PCB.
- 04
The boiler shuts off on its own after being on for a while, without following a clear pattern of use or time.
Cause: An intermittent fault in the PCB, such as a cold solder joint, causes cuts that do not always correspond with the same warning.
Note if the shutdown always occurs when a specific component starts (pump, fan): if so, check that component first.
Fault codes from Saunier Duval that this spare part resolves.
| Code | Fault | Diagnosis and solution |
|---|---|---|
| F13 | Main PCB fault | Yes — it is the direct code of the PCB. Check 230 V, fuse, connectors, and grounding; if it persists, replace the PCB. |
| F11 | No signal is reaching the main circuit | Possible — first rule out wiring and connectors to the PCB; if they are fine, it is usually the PCB. |
| F12 | No signal from the user interface | Normally not — it's usually the display or its cable, not this main PCB. |
| F18 | User interface fault | Normally not — it corresponds to the panel/display, not to this PCB. |
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Data sheet for the Saunier Duval S10470 PCB.
- Catalogue reference
- S10470
- Brand
- Saunier Duval
- Type of part
- PCBs (control boards)
- Units in stock
- 1 unit
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- 1-2 business days
- Return
- 14 days
Data read on the part and in the manufacturer's documentation
What we have not been able to verify does not appear here.
- voltage
- 24V AC
Manuals and technical documentation
Official documentation of the boiler, useful for locating the part and cross-referencing the fault codes.
- Saunier Duval S C 24 E Manual (PDF)Document © Saunier Duval, provided as a technical reference.