Saunier Duval Isofast Condens F 35 E Display Module Ref. S1072300
The control PCB of the Saunier Duval Isofast Condens F 35 E Module Ref. S1072300 manages the ignition, burner modulation, pump, and safety features of the boiler. If it malfunctions, the boiler may fail to start, lock out, or exhibit erratic behavior, with fault codes such as F12, F18, or F13. This module is compatible with models from the Isofast Condens, Isofast, and Isomax ranges, such as the F 30 E and F 35 E, among others. It is recommended to replace it when problems in operation or errors on the display are detected.
VAT included
Consult via WhatsAppSaunier Duval boilers compatible with reference S1072300
PCB with reference S1072300. Seven confirmed compatibilities: F 30 E and F 35 E.
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Saunier Duval F 30 E | Isofast Condens | Contrasted |
| Saunier Duval F 35 E | Isofast Condens | Contrasted |
| Saunier Duval F 30 E H-MOD | Isofast | Contrasted |
| Saunier Duval F 35 E H-MOD | Isofast | Contrasted |
| Saunier Duval F 35 EA | Isofast | Contrasted |
| Saunier Duval F 35 E | Isomax | Contrasted |
| Saunier Duval Condens F 35 E | Isomax | Contrasted |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if ref. S1072300 is the part for your boiler
What determines it is not the boiler model, but the reference printed on the part you already have installed.
- Find the reference printed on the installed part and check whether it matches the catalogue reference S1072300. If it is not visible, do not identify the part from its shape alone.
- Check the full boiler model on its data plate and look for it in the model associations on this page.
- Compare the connections and physical body with the original part before installation.
- If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Symptoms and faults that the PCB S1072300 resolves.
The PCB controls the ignition, modulation, and safety features of the boiler. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
The boiler is completely unresponsive: there are no lights or reactions when pressing buttons.
Cause: The control board is not sending power to the system.
Check the fuse on the PCB and verify that power is reaching it before considering it broken.
- 02
The display shows an error that does not appear in the manual, or it freezes.
Cause: This usually happens when the PCB has a fault in the processor, not just in a sensor.
Cut the power to the boiler for a few minutes and turn it back on before ruling out the PCB.
- 03
The remote control or thermostat does not affect the boiler intermittently.
Cause: Communication between the panel and the PCB is lost and regained for no apparent reason.
Check the connectors of the bus wiring before replacing the PCB; a poor connection can cause the same issue.
- 04
The boiler turns on, runs for a while, and then shuts off by itself, repeating this several times.
Cause: The safety electronics cut off the supply due to a reading that it considers abnormal.
Note the exact fault code each time it shuts down before replacing the PCB: this helps to determine if the fault is with the board or another component.
Fault codes from Saunier Duval that this spare part resolves.
| Code | Fault | Diagnosis and solution |
|---|---|---|
| F12 | No signal from the user interface | Yes — it points to this display/interface module or its connection cable with the main PCB. |
| F18 | User interface fault | Yes — it corresponds to this display/control board module. |
| F13 | Main PCB fault | No — that code is for the MAIN PCB (a different part), not for this display. |
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Data sheet for the Saunier Duval S1072300 PCB.
- Catalogue reference
- S1072300
- Brand
- Saunier Duval
- Type of part
- PCBs (control boards)
- Units in stock
- 4 units
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- Delivery time shown at checkout
- Return
- 14 days
Manuals and technical documentation
Official documentation of the boiler, useful for locating the part and cross-referencing the fault codes.
- Saunier Duval F 35 E H-MOD Manual (PDF)Document © Saunier Duval, provided as a technical reference.