Saunier Duval Isofast Condens F30E Lacroix PCB Ref. S1040000

Saunier Duval Isofast Condens F30E Lacroix PCB Ref. S1040000

The Saunier Duval Isofast Condens F30E PCB, manufactured by Lacroix and with reference S1040000, is the component responsible for controlling the ignition, burner modulation, pump, and safety features of the boiler. When it fails, the boiler may not start, become locked, or operate erratically, which can lead to fault codes such as F.70, F.63, or F.64. This PCB is compatible with models from the Isofast Condens, Isomax Condens, and Isotwin Condens ranges, among others. A technician must confirm through diagnosis whether it needs to be replaced when these symptoms or performance faults occur.

Catalogue reference
S1040000
Warranty
1 year
VAT included OUT OF STOCK
Compatibility

Saunier Duval boilers compatible with reference S1040000

PCB with reference S1040000. Four confirmed compatibilities: F 30 E and F 35 E.

Proven compatibility

Boiler modelFamilyVerification
Saunier Duval F 30 EIsofast CondensContrasted
Saunier Duval F 35 EIsofast CondensContrasted
Saunier Duval F 35 EIsomax CondensContrasted
Saunier Duval F 30 EIsotwin CondensContrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if ref. S1040000 is the part for your boiler

The part reference, model, and equipment revision must be verified against the manufacturer's documentation.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference S1040000. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms that require diagnosis on the PCB S1040000

The PCB controls the ignition, modulation, and safety features of the boiler. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The boiler does not ignite and the display is off.

    Cause: The main control board manages all the electronics of the boiler; without it, nothing starts.

    Check that the boiler is receiving power and that the input fuse of the PCB is in good condition before replacing it.

  • 02

    The display shows an electrical fault code that is not resolved by turning the boiler off and on.

    Cause: The PCB blocks operation when it detects an out-of-range signal in any of the components it monitors.

    Note the code and check its description in the boiler manual: it may be related to a sensor or a peripheral, not with the PCB.

  • 03

    The boiler intermittently stops responding to the controls or the thermostat.

    Cause: An internal continuity fault on the PCB can cause it to lose communication with the rest of the system without warning.

    Check the wiring and connectors of the PCB, ensuring that they are not loose or corroded, before replacing it.

  • 04

    The boiler operates erratically: it stops on its own or changes mode without intervention.

    Cause: This PCB centralizes all the operating logic of the boiler; an internal fault causes inconsistent behaviors.

    Record when the fault occurs (startup, heating, domestic hot water) to rule out that it is a specific component and not the entire PCB.

Fault codes Saunier Duval that require diagnosis

CodeFaultTechnical checks
F.70Invalid product code (DSN).Joint replacement of screen and PCB (S1040000) without reprogramming the DSN or incorrect power/gas coding resistor on the PCB; check in service menu (e.g., d.93), review/code resistor and recode DSN.
F.63EEPROM fault.Memory/electronic fault in the PCB (S1040000); confirm after reset and checking voltages/grounds; if it persists, reprogram or replace the PCB.
F.64Fault in the electronics / NTC.The analog front-end/ADC of the PCB detects a short circuit/impossible readings from the NTC or is faulty; isolate by disconnecting/measuring the NTC and wiring, and if they are correct, replace the PCB.
F.65Fault: electronics temperature.Overheating of the PCB; check for external heat sources/ventilation and actual temperature on electronics; if it reappears without an external cause, replace the PCB.
F.67Fault: electronics/flame.The flame control ASIC on the PCB delivers an implausible signal; measure ionisation current and ground, and if they are correct, the electronics (S1040000) are faulty.
F.42Resistance fault coded (probably in combination with F.70).Gas type coding resistor on the PCB short-circuited/open or incorrectly coded; check value and connections (and those of the power harness) and recode/replace the board if the integrated resistor fails.
F.27Safety shutdown: incorrect flame detection.Moisture/damage in the flame control electronics of the PCB causes out-of-phase flame detection; inspect/retighten seals, dry and check the board and ionization signal before replacing it.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Data sheet for the Saunier Duval S1040000 PCB.

Catalogue reference
S1040000
Uniclima internal SKU
PECICF30E1
Brand
Saunier Duval
Type of part
PCBs (control boards)
Units in stock
0 units
Status
Refurbished
Warranty
1 year
Shipping
Delivery time shown at checkout
Return
14 days

Part data and available documentation

Contrast the label codes, PCB, and revision with the installed part; they are not necessarily equivalent references.

Control platform
SYMSI7.0
Silkscreened code on PCB
0310144400S20
Traceability
902319 / 0020021129 / 443953 / 003981T2 / KWD / IND19 / C0096
PCB flammability marking
GF201 94V-0 (GF P/N 2036288E 2)
Supply voltage
230V
Relay 1
OMRON G5Q-1A-VH, 24VDC (China, batch 1692C5)
Relay 2 (reading with variation between photographs)
SCHRACK / TE Connectivity RY511024 or RY611024, 24VDC
Before purchasing
  • The actual manufacturer is Lacroix, not Saunier Duval; the boiler brand indicates compatibility, not the component manufacturer.
Frequently Asked Questions

Frequently asked questions about the PCB S1040000

Who manufactures the PCB of the Saunier Duval Isofast Condens F30E?
Lacroix, according to the label on the part itself.
Which models are compatible with the Lacroix PCB Ref. S1040000?
It is compatible with the models from the Isofast Condens range F 30 E, F 35 E, the Isomax Condens range F 35 E, and the Isotwin Condens range F 30 E.
When should I replace the PCB in an Isofast Condens F30E?
The technical diagnosis must confirm that it is necessary to replace it, even when there is a PCB fault, the boiler does not ignite, or it does not respond to the controls.
What fault codes are documented for this PCB?
The documented fault codes are: F.70, F.63, F.64, F.65, F.67, F.42, and F.27.
What is the reference for the PCB for the Saunier Duval Isofast Condens F30E?
PECICF30E1 is Uniclima’s internal SKU for locating this listing. To confirm compatibility, check the manufacturer’s reference and the exact appliance model.

Spare parts related to Saunier Duval Isofast Condens

Entrega calculada por destino Delivery time shown at checkout
1-year warranty reviewed and tested
14-day return uninstalled parts
Technical support we verify your model
Saunier Duval Isofast Condens F30E Lacroix PCB Ref. S1040000