Saunier Duval Isofast F 28 E1 PCB - Code 116011 9

Saunier Duval Isofast F 28 E1 PCB - Code 116011 9

Stock · 7 units

The control PCB manages the ignition, burner modulation, pump, and safety features of the boiler. If it has faults, the boiler may fail to start, become locked, or exhibit erratic behavior, displaying fault codes such as 13: Main printed circuit fault or 20: Communication defect between the user interface and the main board. This board is compatible with several models from the Isofast and Isomax ranges, such as the F 28 E1 and the F 35 E1, among others. It should be replaced when these symptoms are detected or when malfunction occurs.

VAT included

Compatibility

Saunier Duval boilers compatible with reference S1019000

PCB with reference S1019000. 11 verified compatibilities: C 28 E1 and C 28 E1 NOX.

Proven compatibility

Boiler modelFamilyVerification
Saunier Duval C 28 E1IsofastContrasted
Saunier Duval C 28 E1 NOxIsofastContrasted
Saunier Duval C 35 E1IsofastContrasted
Saunier Duval F 28 E1IsofastContrasted
Saunier Duval F 35 E1IsofastContrasted
Saunier Duval C 28 E2IsomaxContrasted
Saunier Duval C 28 E204IsomaxContrasted
Saunier Duval C 28 E205IsomaxContrasted
Saunier Duval F 28 E2IsomaxContrasted
Saunier Duval F 28 E204IsomaxContrasted
Saunier Duval F 28 E205IsomaxContrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if ref. S1019000 is the part for your boiler

What determines it is not the boiler model, but the reference printed on the part you already have installed.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference S1019000. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms and faults that the PCB S1019000 resolves.

The PCB controls the ignition, modulation, and safety features of the boiler. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The boiler does not ignite, and the display does not light up.

    Cause: The 125 mA fuse protects the PCB, and if it blows, it cuts off the power supply.

    Measure with a multimeter if the fuse is blown before considering that the PCB is faulty; if it blows again after replacing it, the problem may be elsewhere in the installation.

  • 02

    The pump or the fan is not working even though the boiler seems to be receiving power.

    Cause: The relays that control the pump and the fan may get stuck or not close properly.

    Listen for the relay clicking when calling for heat; if you don't hear it, the relay is not functioning, and it's best to confirm this before replacing the PCB.

  • 03

    The boiler starts but shuts down by itself after a few minutes.

    Cause: The transformer provides low voltage to the control electronics, and if its output drops due to heat, the control unit locks out for safety.

    Measure the output voltage of the transformer with the boiler running and hot; if it drops significantly compared to when it is cold, there may be a thermal fault.

  • 04

    The fault code on the display changes or blinks irregularly.

    Cause: A loose contact or solder joint on the PCB can cause erratic readings that the control unit interprets as different alerts.

    Check if the fault changes when you gently tap the boiler or as it heats up; this behavior suggests a loose connection, not necessarily that the PCB is damaged.

Fault codes from Saunier Duval that this spare part resolves.

CodeFaultDiagnosis and solution
13Main printed circuit board fault.The main PCB (S1019000) does not pass the internal self-diagnosis; this is usually due to an electronics/EEPROM fault or the PCB not generating its internal voltages. Check the 230 V input, fuse, and low voltages (5/15/24 V) on the PCB; if these are correct and the wiring is OK, replace the PCB.
20Communication fault between the user interface and the main PCB.Communication channel/ebus fault on the main board, incompatibility between interface and PCB or defective connection/harness. Check the interface power supply from the board, connectors/harness and test with a known interface; if it persists, the cause is the PCB.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Data sheet for the Saunier Duval S1019000 PCB.

Catalogue reference
S1019000
Brand
Saunier Duval
Type of part
PCBs (control boards)
Units in stock
7 units
Status
Refurbished
Warranty
1 year
Shipping
1-2 business days
Return
14 days

Data read on the part and in the manufacturer's documentation

What we have not been able to verify does not appear here.

Printed marking
SAUNIER DUVAL (logo + text)
Internal PCB code
116011 9 / SOK 02 40
main IC
5DA1596E 090101
secondary IC
AM3740IM8-313SP 206100
transformer
Myrra, VDE certification
relays
Takamisawa JS24M-K and JS24-K, VDE, 8A 250V~AC / RC2A 250V~AC, Japan
fuse
125 mA
Frequently Asked Questions

Frequently asked questions about the PCB S1019000

Is the reference S1019000 the one I should look for on the PCB of the Isofast F 28 E1?
The catalog uses that code, but the readable marking on the PCB is "116011 9 / SOK 02 40"; it is advisable to verify that text on your unit.
Does this PCB Ref. S1019000 work for the Isomax F 28 E2?
Yes, it is listed among the compatible boilers along with Isofast C28E1, C35E1, F28E1, F35E1, and Isomax C28E2.
What relays are on the PCB of the Isofast F 28 E1 and what happens if they fail?
Install two Takamisawa relays, JS24M-K and JS24-K, rated for 8 A at 250 V~; if they fail, it may affect the electrical control of the boiler.
Is there anything else that needs to be checked when replacing this PCB in the Isofast C 35 E1?
The PCB includes a 125 mA fuse; it is advisable to check that it is intact when replacing it.

Spare parts related to Saunier Duval Isomax

Delivery 1–2 daysworking days, mainland Spain
1-year warrantyreviewed and tested
14-day returnuninstalled parts
Technical supportwe verify your model
Saunier Duval Isofast F 28 E1 PCB - Code 116011 9