PCB for Boiler SDHV 19 - Code R-QL2CH

PCB for Boiler SDHV 19 - Code R-QL2CH

Stock · 1 unit

The PCB for the SDHV 19 boiler from Saunier Duval, with reference R-QL2CH, is the component responsible for controlling the ignition, burner modulation, pump, and safety features of the boiler. When this part fails, it is possible that the boiler may not start, become locked, or exhibit erratic behavior. It is compatible with the SDHV 19 boiler, among others. It is recommended to replace it upon noticing these symptoms to restore the proper functioning of the boiler.

VAT included

Compatibility

Compatible Saunier Duval boilers

PCB. A proven compatibility: 19.

Proven compatibility

Boiler modelFamilyVerification
Saunier Duval 19SDHVContrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if it is the part for your boiler

What determines it is not the boiler model, but the reference printed on the part you already have installed.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference —. If it is not visible, do not identify the part by its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms and faults that the PCB (control board) resolves

The PCB controls the ignition, modulation, and safety features of the boiler. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The boiler does not ignite, there is no pilot light or display.

    Cause: The PCB is not supplying voltage, so no component is activated.

    Check the fuse on the PCB and verify that power is reaching the boiler before considering it faulty.

  • 02

    The boiler turns on for a moment and then shuts off by itself.

    Cause: Damaged electronic components can cause intermittent operation failures.

    Note if the shutdown coincides with the use of another device on the same electrical line before replacing the PCB.

  • 03

    The thermostat is calling for heat, but the boiler is not responding.

    Cause: The PCB is not receiving the signal from the thermostat indicating that heat is needed.

    Manually bridge the demand terminals on the terminal block to check if the boiler starts without the thermostat.

  • 04

    The boiler tries to start (fan noise, spark), but it does not activate the pump or the gas valve.

    Cause: If the output relay on the PCB is damaged, there is no voltage reaching the pump or valve, even though the rest is functioning.

    Measure with a multimeter if there is voltage at the output connector to the pump or to the valve when the boiler demands heat.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Saunier Duval PCB data sheet

Brand
Saunier Duval
Type of part
PCBs (control boards)
Units in stock
1 unit
Status
Refurbished
Warranty
1 year
Shipping
1-2 business days
Return
14 days

Data read on the part and in the manufacturer's documentation

What we have not been able to verify does not appear here.

Silkscreen code
R-QL2CH
Frequently Asked Questions

Frequently asked questions about the PCB (control board)

What code is printed on the PCB of the SDHV 19 boiler?
'R-QL2CH', in the lower left corner of the PCB.
Does the PCB of the SDHV 19 boiler have any published catalog reference?
No; the current catalog does not list any reference for this part.
Delivery 1–2 daysworking days, mainland Spain
1-year warrantyreviewed and tested
14-day returnuninstalled parts
Technical supportwe verify your model
PCB for Boiler SDHV 19 - Code R-QL2CH