Saunier Duval Isofast F35 E1 PCB Ref. S1019000

Saunier Duval Isofast F35 E1 PCB Ref. S1019000

Stock · 5 units

The control PCB manages the ignition, burner modulation, pump, and safety features of the boiler. This part, from Myrra and with reference S1019000, is essential for the operation of models such as the Isofast C 28 E1 and F 35 E1, among others. When it fails, the boiler may not start, become locked, or exhibit erratic behavior, which can manifest as fault codes 13 or 20. It is recommended to replace the PCB when these symptoms or operational faults are detected.

VAT included

Compatibility

Saunier Duval boilers compatible with reference S1019000

PCB with reference S1019000. 11 verified compatibilities: C 28 E1 and C 28 E1 NOX.

Proven compatibility

Boiler modelFamilyVerification
Saunier Duval C 28 E1IsofastContrasted
Saunier Duval C 28 E1 NOxIsofastContrasted
Saunier Duval C 35 E1IsofastContrasted
Saunier Duval F 28 E1IsofastContrasted
Saunier Duval F 35 E1IsofastContrasted
Saunier Duval C 28 E2IsomaxContrasted
Saunier Duval C 28 E204IsomaxContrasted
Saunier Duval C 28 E205IsomaxContrasted
Saunier Duval F 28 E2IsomaxContrasted
Saunier Duval F 28 E204IsomaxContrasted
Saunier Duval F 28 E205IsomaxContrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if ref. S1019000 is the part for your boiler

What determines it is not the boiler model, but the reference printed on the part you already have installed.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference S1019000. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms and faults that the PCB S1019000 resolves.

The PCB controls the ignition, modulation, and safety features of the boiler. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The boiler tries to ignite, a clicking sound is heard but the flame does not light.

    Cause: The ignition transformer on the PCB does not generate the necessary spark, and the control unit aborts the cycle.

    Check that the ignition electrode is clean and properly positioned, and that the high voltage cable is not damaged.

  • 02

    The PCB gives no signal: no lights, no display, no startup noise.

    Cause: An internal fault in the control electronics prevents the PCB from receiving or processing the 230V power supply.

    Measure with a multimeter that there is voltage at the input terminals of the PCB before declaring it faulty.

  • 03

    The boiler repeatedly locks out as soon as you try to ignite it.

    Cause: The PCB detects that the ignition has not occurred correctly and cuts off the cycle for safety after several attempts.

    Check the condition of the ionization electrode and the ground connection of the boiler before replacing the PCB.

Fault codes from Saunier Duval that this spare part resolves.

CodeFaultDiagnosis and solution
13Main printed circuit board fault.The main PCB (S1019000) does not pass the internal self-diagnosis; this is usually due to an electronics/EEPROM fault or the PCB not generating its internal voltages. Check the 230 V input, fuse, and low voltages (5/15/24 V) on the PCB; if these are correct and the wiring is OK, replace the PCB.
20Communication fault between the user interface and the main PCB.Communication channel/ebus fault on the main board, incompatibility between interface and PCB or defective connection/harness. Check the interface power supply from the board, connectors/harness and test with a known interface; if it persists, the cause is the PCB.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Data sheet for the Saunier Duval S1019000 PCB.

Catalogue reference
S1019000
Brand
Saunier Duval
Type of part
PCBs (control boards)
Units in stock
5 units
Status
Refurbished
Warranty
1 year
Shipping
1-2 business days
Return
14 days

Data read on the part and in the manufacturer's documentation

What we have not been able to verify does not appear here.

Supply voltage
230V
Ignition transformer - manufacturer
Myrra
Ignition transformer - model
LA1701X (Poland)
Frequently Asked Questions

Frequently asked questions about the PCB S1019000

Does this PCB Ref. S1019000 fit the Saunier Duval Isofast C28, C35, F28, and F35 E1?
Yes, it is compatible with Isofast C28 E1 (and NOX), C35 E1, F28 E1, F35 E1, and Isomax C28 E2 and F28 E2.
What voltage does the PCB of the Isofast F35 E1 operate at?
230V, according to the label on the part itself.
What ignition transformer is installed on this PCB of the Isofast F35 E1?
A Myrra LA1701X transformer, manufactured in Poland.
When should this PCB be replaced in an Isofast or Isomax?
When the original PCB fails and the boiler does not ignite or gets locked.

Spare parts related to Saunier Duval Isomax

Delivery 1–2 daysworking days, mainland Spain
1-year warrantyreviewed and tested
14-day returnuninstalled parts
Technical supportwe verify your model
Saunier Duval Isofast F35 E1 PCB Ref. S1019000