Saunier Duval Themaclassic C25E PCB - Code SYMSI7.0 / 0310144400L12

Saunier Duval Themaclassic C25E PCB - Code SYMSI7.0 / 0310144400L12

Stock · 17 units

The Saunier Duval Themaclassic C25E - SYMSI7.0 PCB controls the ignition, burner modulation, pump, and safety features of the boiler. When it fails, the boiler may not start, become locked, or exhibit erratic behavior. Users may notice fault codes such as F13, F11, F12, or F18. This PCB is compatible with models from the ThemaClassic, Themafast, Thematek, Isotwin, Isofast, and Thema ranges, among others. It is recommended to replace the PCB when it shows operational faults.

VAT included

Compatibility

Saunier Duval boilers compatible with reference S10470

PCB with reference S10470. 33 verified compatibilities: F 25 E and F 24 E.

Proven compatibility

Boiler modelFamilyVerification
Saunier Duval F 25 EThemaClassicContrasted
Saunier Duval F 24 EThemaClassicContrasted
Saunier Duval C 24 EThemaClassicContrasted
Saunier Duval C 25 EThemaClassicContrasted
Saunier Duval C AS 24 EThemaClassicContrasted
Saunier Duval C AS 25 EThemaClassicContrasted
Saunier Duval F AS 24 EThemaClassicContrasted
Saunier Duval F AS 25 EThemaClassicContrasted
Saunier Duval F AS 30 EThemaClassicContrasted
Saunier Duval C 24 EThemafastContrasted
Saunier Duval C 25 EThemafastContrasted
Saunier Duval C 28 EThemafastContrasted
Saunier Duval C 30 EThemafastContrasted
Saunier Duval F 24 EThemafastContrasted
Saunier Duval F 25 EThemafastContrasted
Saunier Duval F 25 E H-MODThemafastContrasted
Saunier Duval F 30 EThemafastContrasted
Saunier Duval F 30 E H-MODThemafastContrasted
Saunier Duval C 24 EThematekContrasted
Saunier Duval C 24 EO BTThematekContrasted
Saunier Duval F 24 EThematekContrasted
Saunier Duval S C 24 EThematekContrasted
Saunier Duval S F 24 EThematekContrasted
Saunier Duval C 24 EAIsotwinContrasted
Saunier Duval C 28 EAIsotwinContrasted
Saunier Duval C 24 E ad04IsotwinContrasted
Saunier Duval C 24 E de04IsotwinContrasted
Saunier Duval F 24 EIsotwinContrasted
Saunier Duval F 24 EAIsotwinContrasted
Saunier Duval F 28 EAIsotwinContrasted
Saunier Duval F 30 E H-MODIsofastContrasted
Saunier Duval F 35 E H-MODIsofastContrasted
Saunier Duval F 25 E STLThemaContrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if ref. S10470 is the part for your boiler

What determines it is not the boiler model, but the reference printed on the part you already have installed.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference S10470. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms and faults that the PCB S10470 resolves

The PCB controls the ignition, modulation, and safety features of the boiler. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The boiler ignites the burner, but the pump or the fan does not start, although the rest of the indicators are fine.

    Cause: The PCB controls those outputs through relays; if one fails, the component that depends on it does not receive the start command.

    Before changing the PCB, listen for the click of the relay when the start command is given; if it doesn't click, the PCB may be the problem.

  • 02

    Different fault codes appear every few days, without any changes in the installation.

    Cause: The microprocessor on the PCB processes the signals from sensors; if an internal component fails intermittently, the codes change without there being a real problem in the boiler.

    Note the exact sequence of fault codes and the time they appear; if they do not follow a pattern related to an external component (sensor, pressure switch), the PCB is suspect.

  • 03

    The remote control or thermostat is not communicating with the boiler: it does not send temperature or receive status.

    Cause: The communication between the control and the boiler goes through the driver of the PCB; if that circuit fails, the control will not work even if it has new batteries.

    Test the remote control on another compatible boiler if possible, or check that the cable or communication bus is properly connected to the terminal block of the PCB before ruling it out.

  • 04

    The boiler stops by itself during combustion and needs to be reset to start again, and this happens again in a few days.

    Cause: A microcut or a cold solder joint within the PCB causes the system to recover with the reset but then fail again.

    Keep track of how many times it resets per day; if the frequency increases over time, it is more likely to be the PCB and not a one-time sensor fault.

Fault codes from Saunier Duval that this spare part resolves.

CodeFaultDiagnosis and solution
F13Main PCB faultYes — it is the direct code of the PCB. Check 230 V, fuse, connectors, and grounding; if it persists, replace the PCB.
F11No signal is reaching the main circuitPossible — first rule out wiring and connectors to the PCB; if they are fine, it is usually the PCB.
F12No signal from the user interfaceNormally not — it's usually the display or its cable, not this main PCB.
F18User interface faultNormally not — it corresponds to the panel/display, not to this PCB.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Data sheet for the Saunier Duval S10470 PCB.

Catalogue reference
S10470
Brand
Saunier Duval
Type of part
PCBs (control boards)
Units in stock
17 units
Status
Refurbished
Warranty
1 year
Shipping
1-2 business days
Return
14 days

Data read on the part and in the manufacturer's documentation

What we have not been able to verify does not appear here.

PCB model (silkscreened)
SYMSI7.0
PCB code (silkscreened)
0310144400L12
Additional code printed on the PCB
125072-12 CA0-7047 F6
Supply voltage
230V
Output relays
Omron G5Q-1A / G5Q-1 DC24V (x4), marked China 1574CC/2184CC, 5A 30VDC / 10A 250VAC
Output driver chip
Toshiba ULN2803A
Optocoupler
Cosmo 4N35 (marked COSMO 2010 4N35 D46 B)
Documentation

Manuals and technical documentation

Official documentation of the boiler, useful for locating the part and cross-referencing the fault codes.

Frequently Asked Questions

Frequently asked questions about the PCB S10470

Does this PCB work for an Isotwin F24E or only for the Themaclassic C25E?
Yes, Isotwin F24E is also on the list of compatible boilers in this document, along with Isofast F30E/F35E, Thema F25E STL, and several Themafast and Themaclassic models.
What relays are installed on the PCB of the Themaclassic C25E?
Four Omron relays G5Q-1A/G5Q-1 of 24V, for loads up to 5A at 30VDC or 10A at 250VAC.
What control components does this PCB have besides the relays?
A Toshiba ULN2803A driver and a Cosmo 4N35 optocoupler, according to the label.

Spare parts related to Saunier Duval ThemaClassic

Delivery 1–2 daysworking days, mainland Spain
1-year warrantyreviewed and tested
14-day returnuninstalled parts
Technical supportwe verify your model