Saunier Duval Themaplus F 23 E PCB (control board)
PCB manufactured by Saunier Duval (according to external sources), for boilers in the Combitek, Thema, and Themaplus ranges in version C/F 23 E. The label shows the transformer data (23535-A, 24V 50/60Hz, 48V 0.05VA), the mains voltage of 230V, and the fuses: 200mA T without indicator and 80mA T with indicator. It is replaced when the original electronic control fails.
VAT included
Consult via WhatsAppSaunier Duval boilers compatible with reference 05741000
PCB with reference 05741000. Eight confirmed compatibilities: C 23 E and F 23 E.
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Saunier Duval C 23 E | Thema | Contrasted |
| Saunier Duval F 23 E | Thema | Contrasted |
| Saunier Duval C AS 23 E | Thema | Contrasted |
| Saunier Duval F AS 23 E | Thema | Contrasted |
| Saunier Duval C 23 E | Themaplus | Contrasted |
| Saunier Duval F 23 E | Themaplus | Contrasted |
| Saunier Duval C 23 E | Combitek | Contrasted |
| Saunier Duval F 23 E | Combitek | Contrasted |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if ref. 05741000 is the part for your boiler
What determines it is not the boiler model, but the reference printed on the part you already have installed.
- Find the reference printed on the installed part and check whether it matches the catalogue reference 05741000. If it is not visible, do not identify the part from its shape alone.
- Check the full boiler model on its data plate and look for it in the model associations on this page.
- Compare the connections and physical body with the original part before installation.
- If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Symptoms and faults that the PCB 05741000 resolves.
The PCB controls the ignition, modulation, and safety features of the boiler. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
The boiler does not ignite, and upon opening it, the fuse is blown.
Cause: The fuse blows if there is a problem with the power supply to the PCB.
Before changing the PCB, check which fuse your version uses and if the new one blows when powered on.
- 02
The electronic control stops responding to the panel controls: it doesn't change temperature or mode.
Cause: The electronic control is not processing user commands, which may indicate that it is failing.
Try turning off and on from the main switch; if the panel still does not respond, the electronic control is faulty.
- 03
The boiler ignites the pilot but does not switch to the main flame.
Cause: The PCB does not allow the pilot to switch to the main flame if there is a fault in the relay circuit.
Check that the pilot stays lit for several minutes; if it is steady and does not transition to the main flame, point to the electronic control.
- 04
It smells like burning or there is a dark mark next to the transformer on the PCB.
Cause: The transformer can overheat if the electronic control fails.
With the boiler unplugged, check for discoloration or smell around the transformer before replacing it.
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Data sheet for the Saunier Duval 05741000 PCB.
- Catalogue reference
- 05741000
- Brand
- Saunier Duval
- Type of part
- PCBs (control boards)
- Units in stock
- 1 unit
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- 1-2 business days
- Return
- 14 days
Data read on the part and in the manufacturer's documentation
What we have not been able to verify does not appear here.
- Component manufacturer
- Saunier Duval
- Transformer (modelo)
- 23535-A
- Primary transformer
- 24V 50/60Hz (6-10)
- Secondary transformer
- 48V 0.05VA (ta 70/B)
- Mains voltage
- 230 V
- Fuse without pilot (SANS VEILLEUSE)
- 200 mA T
- Fuse with pilot light (AVEC VEILLEUSE)
- 80 mA T
- IC1 (regulator)
- REG. SAV 1496b1s HEX 6EE6