Honeywell PCB Master Inox / Supermaster 24 SE Ref. 0020076179

Honeywell PCB Master Inox / Supermaster 24 SE Ref. 0020076179

Stock · 21 units

The Honeywell Master Inox / Supermaster 24 SE PCB (control board) acts as the brain of the boiler, controlling the ignition, burner modulation, pump, and safety features. If it fails, the boiler may not start, become locked, or exhibit erratic behavior, and you might see fault codes 13 or 11. This board is compatible with models such as the Supermaster 24 SE, 28 SE, 30 SE, among others. It is advisable to replace it when you notice these symptoms or if a fault in the main printed circuit board is identified.

VAT included

Compatibility

Saunier Duval boilers compatible with reference 0020076179

PCB with reference 0020076179. Eight confirmed compatibilities: F 24 and 24 SE.

Proven compatibility

Boiler modelFamilyVerification
Saunier Duval F 24NOX ThemaContrasted
Saunier Duval 24 SESupermasterContrasted
Saunier Duval 28 SESupermasterContrasted
Saunier Duval 30 SESupermasterContrasted
Saunier Duval Ecoplus 24 SESupermicraContrasted
Saunier Duval Master Inox 24 SEHermannContrasted
Saunier Duval Master Inox 30 SEHermannContrasted
Saunier Duval Supermicra Condensing 24 SEHermannContrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if ref. 0020076179 is the part for your boiler

What determines it is not the boiler model, but the reference printed on the part you already have installed.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference 0020076179. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms and faults that the PCB 0020076179 resolves.

The PCB controls the ignition, modulation, and safety features of the boiler. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The boiler does not ignite and there is no power at any output of the PCB.

    Cause: The transformer on the PCB, which reduces the mains voltage to the control voltage, has stopped working.

    Measure with a multimeter if there is voltage at the input of the PCB before assuming that the transformer is faulty.

  • 02

    An error code appears that doesn't clear even after several resets.

    Cause: The PCB locks for safety when it detects an out-of-range signal in flame, pressure, or temperature.

    Check the sensor associated with that exact fault code before replacing the entire PCB.

  • 03

    A repeated clicking sound is heard on the PCB, but the pump or burner do not start.

    Cause: One of the relays on the PCB does not close the contact properly.

    Listen to see if the clicking coincides with the moment the burner or the pump should start; if so, the relay may be the problem.

  • 04

    The control or the thermostat cannot get the boiler to respond.

    Cause: The communication stage of the PCB that processes the command from the room thermostat is failing.

    Test the thermostat or check its wiring before blaming the PCB.

Fault codes from Saunier Duval that this spare part resolves.

CodeFaultDiagnosis and solution
13Main PCB fault.The main PCB is faulty or has defective internal/external connections; check the fuse and voltages of the PCB (230/5 V supplies) and connectors. If the issue persists with correct wiring and peripherals, replace the PCB.
11No reception from the main PCB (MMI line).Communication fault towards the PCB (receiver/MMI input of the PCB) or the cable between interface and PCB; check continuity of the MMI lead and 5 V on the interface. If the fault persists with a good cable/panel, the PCB is the cause.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Data sheet for the Saunier Duval PCB 0020076179.

Catalogue reference
0020076179
Brand
Saunier Duval
Type of part
PCBs (control boards)
Units in stock
21 units
Status
Refurbished
Warranty
1 year
Shipping
1-2 business days
Return
14 days

Data read on the part and in the manufacturer's documentation

What we have not been able to verify does not appear here.

Manufacturer (logo on PCB)
Honeywell
Code
Cd. 052.003579/03
Transformer
COMELIT T4880E116FP2, primary 230Vac 50/60Hz, secondary 16.5Vac 8VA
Relays
TAKAMISAWA JV24S-KT, 5A 30VDC / 250VAC, coil 24VDC
Software review
R155F
Frequently Asked Questions

Frequently asked questions about the PCB 0020076179

Is the manufacturer of the PCB of the Supermaster Inox 24 SE Honeywell?
Yes, the Honeywell logo is printed next to one of the relays on the PCB.
Is this PCB compatible with the Thema Nox F24?
Yes, Thema Nox F24 is on the confirmed list of compatible boilers for this PCB.
What transformer and relays are installed on the PCB of the Master Inox 24 SE / 30 SE?
A Comelit T4880E116FP2 transformer (230Vac / 16.5Vac 8VA) and Takamisawa JV24S-KT relays rated at 24V, according to the label.
When should this PCB be replaced in a Supermicra 24 SE Ecoplus?
When the electronic control of the boiler fails, what is the reason for replacement recorded in this file?

Spare parts related to Saunier Duval Supermaster

Delivery 1–2 daysworking days, mainland Spain
1-year warrantyreviewed and tested
14-day returnuninstalled parts
Technical supportwe verify your model
Honeywell PCB Master Inox / Supermaster 24 SE Ref. 0020076179