Saunier Duval Combitek F23E PCB Ref. ST1390 CAD 4685

Saunier Duval Combitek F23E PCB Ref. ST1390 CAD 4685

The Saunier Duval Combitek F23E PCB, reference ST1390, is a control component that manages the ignition, burner modulation, pump, and safety features of the boiler. When this part fails, the boiler may not start, become locked, or behave erratically. It is installed in models such as Combitek F23E and Combitek C23E, among others. A technician must confirm through diagnosis whether it needs to be replaced upon noticing these symptoms to avoid malfunction in the heating system.

Catalogue reference
05728600
Warranty
1 year
VAT included Stock · 1 unit
Compatibility

Saunier Duval boilers compatible with reference 05728600

PCB with reference 05728600. Two confirmed compatibilities: Combitek F23E and Combitek C23E.

Proven compatibility

Boiler modelFamilyVerification
Saunier Duval Combitek F23ECombitekContrasted
Saunier Duval Combitek C23ECombitekContrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if ref. 05728600 is the part for your boiler

The part reference, model, and equipment revision must be verified against the manufacturer's documentation.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference 05728600. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms that require diagnosis on the PCB 05728600

The PCB controls the ignition, modulation, and safety features of the boiler. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The boiler does not ignite or attempt to start at any time.

    Cause: The PCB does not send the ignition signal; if its control circuit fails, the boiler remains stopped.

    Before changing the PCB, check that power is reaching it and that the thermostat or the programmer clock is not requesting to turn off.

  • 02

    The boiler does not respond to the panel controls: the buttons do nothing.

    Cause: If the integrated circuit of the PCB fails, the buttons have no effect even though the display is on.

    Try turning off and then turning on the boiler (full reset) before replacing the PCB.

  • 03

    The display shows a generic fault on the PCB without further details.

    Cause: The electronics self-diagnose as the source of the fault when the fault does not correspond to any external component.

    Check the manual for the exact fault code before purchasing: some 'PCB' faults may indicate the transformer or internal wiring.

  • 04

    The boiler ignites for a moment and then turns off by itself, without any apparent reason.

    Cause: If the transformer supplying the PCB has an unstable voltage, the electronics may start the cycle and cut it off for safety.

    Before changing the PCB, measure if the output voltage of the transformer is stable.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Data sheet for the Saunier Duval 05728600 PCB.

Catalogue reference
05728600
Uniclima internal SKU
PLCOBTK23
Brand
Saunier Duval
Type of part
PCBs (control boards)
Units in stock
1 unit
Status
Refurbished
Warranty
1 year
Shipping
Delivery time shown at checkout
Return
14 days

Part data and available documentation

Contrast the label codes, PCB, and revision with the installed part; they are not necessarily equivalent references.

Silkscreen code
ST1390 CAD 4685
White label code
10063643
Documentation

Manuals and technical documentation

Official documentation of the boiler, useful for locating the part and cross-referencing the fault codes.

Frequently Asked Questions

Frequently asked questions about the PCB 05728600

What code do I need to check printed on my PCB to confirm that it is the one for the Combitek F23E?
The code ST1390 CAD 4685 printed on the PCB.
What fault of the Saunier Duval Combitek F23E does changing this PCB solve?
It should be checked when the boiler does not ignite, does not respond to the controls, or shows a fault on the PCB. Replacement requires a technical diagnosis.
What else is mounted on this PCB of the Combitek F23E, apart from the silkscreen code?
A transformer and a DIP integrated circuit with inconclusive texts.

Spare parts related to Saunier Duval Combitek

Entrega calculada por destino Delivery time shown at checkout
1-year warranty reviewed and tested
14-day return uninstalled parts
Technical support we verify your model
Saunier Duval Combitek F23E PCB Ref. ST1390 CAD 4685