PCB Saunier Duval ThemaClassic / IsoFast / IsoTwin Ref. S10470

PCB Saunier Duval ThemaClassic / IsoFast / IsoTwin Ref. S10470

Stock · 1 unit

Saunier Duval ThemaClassic / IsoFast / IsoTwin PCB Ref. S10470. This control PCB manages the ignition, burner modulation, pump, and safety features of the boiler. If it fails, you will notice that the boiler does not start, locks out, or exhibits erratic behavior. It is compatible with boilers from the ThemaClassic, Themafast, and Thematek ranges, such as models C 24 E, C 25 E, F 24 E, F 25 E, among others. It is recommended to replace it when you experience these operational issues.

VAT included

Compatibility

Saunier Duval boilers compatible with reference S10470

PCB with reference S10470. Nine confirmed compatibilities: C 24 E and C 25 E.

Proven compatibility

Boiler modelFamilyVerification
Saunier Duval C 24 EThemaClassicContrasted
Saunier Duval C 25 EThemaClassicContrasted
Saunier Duval F 24 EThemaClassicContrasted
Saunier Duval F 25 EThemaClassicContrasted
Saunier Duval F 25 E H-MODThemafastContrasted
Saunier Duval F 30 E H-MODThemafastContrasted
Saunier Duval SF 24 EThematekContrasted
Saunier Duval F 30 E H-MODIsofastContrasted
Saunier Duval F 35 E H-MODIsofastContrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if ref. S10470 is the part for your boiler

What determines it is not the boiler model, but the reference printed on the part you already have installed.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference S10470. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms and faults that the PCB S10470 resolves

The PCB controls the ignition, modulation, and safety features of the boiler. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The boiler shows no signs of life: no display, no indicator light, no attempt to start.

    Cause: The PCB manages the ignition; if it fails, the unit does not respond even if it receives power and gas.

    Check the main fuse of the installation and that 230V is reaching the boiler before suspecting the PCB.

  • 02

    The wall thermostat is not able to start the boiler.

    Cause: The PCB receives the heat command and decides to start; if it does not process that signal correctly, the boiler remains on standby.

    Check that the thermostat is actually calling for heat (indicator light or display on the thermostat itself) before ruling out the PCB.

  • 03

    The boiler starts but stops on its own after a few seconds or minutes, irregularly.

    Cause: An intermittent fault on the PCB interrupts the control sequence even though the rest of the components are functioning properly.

    Check if the cut always occurs at the same point in the cycle or if it is random; this helps to distinguish between electronics and a point sensor.

  • 04

    An error code appears on the screen that changes or comes and goes without apparent reason.

    Cause: The PCB misinterprets the signals from sensors or internal communications and generates inconsistent alerts.

    Note the different codes that appear and in what order; an erratic pattern points more to the PCB than to a single sensor.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Data sheet for the Saunier Duval S10470 PCB.

Catalogue reference
S10470
Brand
Saunier Duval
Type of part
PCBs (control boards)
Units in stock
1 unit
Status
Refurbished
Warranty
1 year
Shipping
1-2 business days
Return
14 days

Data read on the part and in the manufacturer's documentation

What we have not been able to verify does not appear here.

voltage
24V
current
6A
alternating current
24VAC
supply voltage
230V
Documentation

Manuals and technical documentation

Official documentation of the boiler, useful for locating the part and cross-referencing the fault codes.

Frequently Asked Questions

Frequently asked questions about the PCB S10470

Is this PCB compatible with the IsoTwin C24EA?
Yes, the IsoTwin C24EA is on the list of compatible models.
Does this PCB work for the ThemaFast F25E?
Yes, the ThemaFast F25E is among the listed compatible Saunier Duval models.

Spare parts related to Saunier Duval ThemaClassic

Delivery 1–2 daysworking days, mainland Spain
1-year warrantyreviewed and tested
14-day returnuninstalled parts
Technical supportwe verify your model