Main PCB Saunier Duval Isofast Condens F35 A 1 Ref. 0020212697

Main PCB Saunier Duval Isofast Condens F35 A 1 Ref. 0020212697

The Main PCB Saunier Duval Isofast Condens F35 A 1 is the component that controls the ignition, the modulation of the burner, the pump, and the safety features of the boiler. When it malfunctions, the boiler may fail to start, become locked, or operate erratically. The associated fault codes include F.63, F.64, F.65, and F.67, which indicate specific issues in the boiler's electronics. This board is compatible with models from the Isofast Condens range, such as the Isofast Condens F35 A/1, among others. A technician must confirm through diagnosis whether replacement is necessary when these malfunction symptoms are detected.

Catalogue reference
0020212697
Warranty
1 year
VAT included Stock · 1 unit
Compatibility

Saunier Duval boilers compatible with reference 0020212697

PCB with reference 0020212697. A proven compatibility: Isofast Condens F35 A/1.

Verified compatibility

Boiler modelFamilyVerification
Saunier Duval Isofast Condens F35 A/1Isofast CondensVerified

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if ref. 0020212697 is the part for your boiler

The part reference, model, and equipment revision must be verified against the manufacturer's documentation.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference 0020212697. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms that require diagnosis on the PCB 0020212697

The PCB controls the ignition, modulation, and safety features of the boiler. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The boiler does not ignite, nor does the pilot light activate.

    Cause: If the PCB does not work, the boiler cannot be started, even if it receives power.

    Check the internal fuse of the PCB and make sure it receives 230V before replacing it.

  • 02

    A different fault code appears frequently, without repeating.

    Cause: A damaged PCB can randomly trigger safety protections due to faults in its readings.

    Note the fault codes for a few days: if there is no pattern, it is most likely that the problem is with the PCB.

  • 03

    The remote control or the thermostat do not connect to the boiler.

    Cause: The PCB contains the communication module; if it fails, the boiler does not receive external commands.

    Test the remote control in another installation if you can, or check the batteries and the bus wiring.

  • 04

    The boiler starts but shuts down after a few seconds without modulating.

    Cause: The PCB can interrupt the ignition before the flame stabilizes.

    Make sure there is no ionization or pressure error on the display indicating another issue before replacing the PCB.

Fault codes Saunier Duval that require diagnosis

CodeFaultTechnical checks
F.63EEPROM memory fault of the boiler's electronic control.This symptom may be related to the part, but it does not confirm that it is faulty. A technician must check the equipment and its inspection according to the manual before deciding on a repair or replacement.
F.64Fault in the electronics related to the NTC sensor input.The processing of the NTC signal is done by the PCB; with the short circuit in the NTC flow/return sensor ruled out (measure the sensor's resistance), the remaining documented cause is a fault in the electronics/PCB itself.
F.65Electronic temperature fault (PCB overheating).It is detected and caused by the PCB itself; first verify that there is no external source of abnormal heat and, if ruled out, the code indicates a fault in the electronics/PCB.
F.67Electronics/flame fault: flame signal not plausible for the control.The flame signal detection and validation circuit is on the PCB; when the received signal is not plausible and the ionisation electrode is ruled out, the documented cause is an electronics/PCB fault.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Data sheet for the Saunier Duval PCB 0020212697

Catalogue reference
0020212697
Uniclima internal SKU
PLCIFSTF351X
Brand
Saunier Duval
Type of part
PCBs (control boards)
Units in stock
1 unit
Status
Refurbished
Warranty
1 year
Shipping
Delivery time shown at checkout
Return
14 days

Part data and available documentation

Contrast the label codes, PCB, and revision with the installed part; they are not necessarily equivalent references.

voltage
240 Vac
Documentation

Manuals and technical documentation

Official documentation of the boiler, useful for locating the part and cross-referencing the fault codes.

Frequently asked questions

Frequently asked questions about the PCB 0020212697

For which other boilers besides the Isofast Condens F35 A/1 is this PCB Ref. 0020212697 suitable?
For no other: the available material only shows compatibility with the Saunier Duval Isofast Condens F35 A/1.

Spare parts related to Saunier Duval Isofast Condens

Delivery calculated by destination Delivery time shown at checkout
1-year warranty inspected and tested
14-day return uninstalled parts
Technical support we verify your model
Main PCB Saunier Duval Isofast Condens F35 A 1 Ref. 0020212697