Saunier Duval Boiler PCB F25E - Code 0020146496 (TC-AE / TM-AE1)
RefurbishedPCBs (control boards)

Saunier Duval Boiler PCB F25E - Code 0020146496 (TC-AE / TM-AE1)

Stock · 1 unit

If your boiler does not start, gets blocked, or exhibits erratic behavior, you may need the Saunier Duval F25E PCB, with reference 0020146496. This board controls the ignition, burner modulation, pump, and safety features of the boiler. It is used in several Saunier Duval models, including the F25E. It is advisable to replace it when you notice these fault symptoms to restore the proper functioning of your boiler.

VAT included

Guide

How to check if it is the part for your boiler

What determines it is not the boiler model, but the reference printed on the part you already have installed.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference —. If it is not visible, do not identify the part by its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms and faults that the PCB (control board) resolves

The PCB controls the ignition, modulation, and safety features of the boiler. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The boiler is completely off, with no lights on.

    Cause: The PCB is not supplying power to the rest of the circuit due to an internal fault.

    Check that the boiler is receiving 230V from the mains and that no main fuse has blown before inspecting the PCB.

  • 02

    Try to start it, it makes a starting noise and then cuts off immediately.

    Cause: The PCB detects an anomaly in the ignition sequence and cuts off the cycle for safety.

    Check if the cut always occurs at the same point during the start-up; this helps to distinguish a PCB fault from another component.

  • 03

    The control panel does not respond to any button.

    Cause: The microcontroller on the PCB has stopped reading the commands from the keyboard or the display.

    Try disconnecting and reconnecting the connector of the panel before replacing the entire PCB.

  • 04

    A different fault code appears every few days.

    Cause: Indicates an intermittent fault in the control board, not a fixed fault of another component.

    Keep a record of the codes and the dates they appear, help confirm the pattern before purchasing.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

PCB data sheet

Type of part
PCBs (control boards)
Units in stock
1 unit
Status
Refurbished
Warranty
1 year
Shipping
1-2 business days
Return
14 days

Data read on the part and in the manufacturer's documentation

What we have not been able to verify does not appear here.

Part code (barcode)
0020146496
Batch/week code
2194 0067 G
Silkscreen reference
TC-AE / TM-AE1
Printed industrial group on the edge
V-Group
Variant
Combi
Auxiliary output voltage
24 V
Mains voltage
230 V
References for components/connectors in silkscreen printing
X102 P2, K101, K102, K104, K108, C26/C32, C14, C15, C12, R10, R111, R112, R113
Documentation

Manuals and technical documentation

Official documentation of the boiler, useful for locating the part and cross-referencing the fault codes.

Frequently Asked Questions

Frequently asked questions about the PCB (control board)

Is this PCB compatible with any boiler model?
No, there are currently no confirmed models compatible with the PCB of the Saunier Duval F25E boiler – Code 0020146496.
What is the reference for this PCB?
The reference for this PCB is RPE ST-F25E.
What voltages does this PCB from the Saunier Duval F25E handle?
It operates on 230 V mains and 24 V auxiliary output, as indicated on the label.
What batch includes the PCB with references TC-AE / TM-AE1?
The batch is 2194 0067 G, as stated on the label.
Are there documented fault codes for this PCB?
No, there are no documented fault codes for this product.

Spare parts related to

Delivery 1–2 daysworking days, mainland Spain
1-year warrantyreviewed and tested
14-day returnuninstalled parts
Technical supportwe verify your model
Saunier Duval Boiler PCB F25E - Code 0020146496 (TC-AE / TM-AE1)