Saunier Duval Boiler PCB F25E - Code 0020146496 (TC-AE / TM-AE1)
If your boiler does not start, gets blocked, or exhibits erratic behavior, you may need the Saunier Duval F25E PCB, with reference 0020146496. This board controls the ignition, burner modulation, pump, and safety features of the boiler. It is used in several Saunier Duval models, including the F25E. It is advisable to replace it when you notice these fault symptoms to restore the proper functioning of your boiler.
VAT included
Consult via WhatsAppHow to check if it is the part for your boiler
What determines it is not the boiler model, but the reference printed on the part you already have installed.
- Find the reference printed on the installed part and check whether it matches the catalogue reference —. If it is not visible, do not identify the part by its shape alone.
- Check the full boiler model on its data plate and look for it in the model associations on this page.
- Compare the connections and physical body with the original part before installation.
- If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Symptoms and faults that the PCB (control board) resolves
The PCB controls the ignition, modulation, and safety features of the boiler. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
The boiler is completely off, with no lights on.
Cause: The PCB is not supplying power to the rest of the circuit due to an internal fault.
Check that the boiler is receiving 230V from the mains and that no main fuse has blown before inspecting the PCB.
- 02
Try to start it, it makes a starting noise and then cuts off immediately.
Cause: The PCB detects an anomaly in the ignition sequence and cuts off the cycle for safety.
Check if the cut always occurs at the same point during the start-up; this helps to distinguish a PCB fault from another component.
- 03
The control panel does not respond to any button.
Cause: The microcontroller on the PCB has stopped reading the commands from the keyboard or the display.
Try disconnecting and reconnecting the connector of the panel before replacing the entire PCB.
- 04
A different fault code appears every few days.
Cause: Indicates an intermittent fault in the control board, not a fixed fault of another component.
Keep a record of the codes and the dates they appear, help confirm the pattern before purchasing.
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
PCB data sheet
- Type of part
- PCBs (control boards)
- Units in stock
- 1 unit
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- 1-2 business days
- Return
- 14 days
Data read on the part and in the manufacturer's documentation
What we have not been able to verify does not appear here.
- Part code (barcode)
- 0020146496
- Batch/week code
- 2194 0067 G
- Silkscreen reference
- TC-AE / TM-AE1
- Printed industrial group on the edge
- V-Group
- Variant
- Combi
- Auxiliary output voltage
- 24 V
- Mains voltage
- 230 V
- References for components/connectors in silkscreen printing
- X102 P2, K101, K102, K104, K108, C26/C32, C14, C15, C12, R10, R111, R112, R113
Manuals and technical documentation
Official documentation of the boiler, useful for locating the part and cross-referencing the fault codes.
- Saunier Duval F25E Boiler Electronic Manual – Code 002014649 (PDF)Document ©, provided as a technical reference.