PCB Saunier Duval Thema C 25 E Ref. S1047000

PCB Saunier Duval Thema C 25 E Ref. S1047000

Stock · 1 unit

The Saunier Duval Thema C 25 E PCB (control board) Ref. S1047000 is a component manufactured by OMRON. Its main function is to control the ignition, the modulation of the burner, the pump, and the safety features of the boiler. If it malfunctions, the boiler may fail to start, become locked, or behave erratically, displaying faults such as F13, F11, F12, or F18. This board is compatible with several models, including the ThemaClassic F 25 E, C 25 E, and C AS 25 E, among others. It should be replaced when these operational issues are detected.

VAT included

Compatibility

Saunier Duval boilers compatible with reference S1047000

PCB with reference S1047000. 33 verified compatibilities: F 25 E and F 24 E.

Proven compatibility

Boiler modelFamilyVerification
Saunier Duval F 25 EThemaClassicContrasted
Saunier Duval F 24 EThemaClassicContrasted
Saunier Duval C 24 EThemaClassicContrasted
Saunier Duval C 25 EThemaClassicContrasted
Saunier Duval C AS 24 EThemaClassicContrasted
Saunier Duval C AS 25 EThemaClassicContrasted
Saunier Duval F AS 24 EThemaClassicContrasted
Saunier Duval F AS 25 EThemaClassicContrasted
Saunier Duval F AS 30 EThemaClassicContrasted
Saunier Duval C 24 EThemafastContrasted
Saunier Duval C 25 EThemafastContrasted
Saunier Duval C 28 EThemafastContrasted
Saunier Duval C 30 EThemafastContrasted
Saunier Duval F 24 EThemafastContrasted
Saunier Duval F 25 EThemafastContrasted
Saunier Duval F 25 E H-MODThemafastContrasted
Saunier Duval F 30 EThemafastContrasted
Saunier Duval F 30 E H-MODThemafastContrasted
Saunier Duval C 24 EThematekContrasted
Saunier Duval C 24 EO BTThematekContrasted
Saunier Duval F 24 EThematekContrasted
Saunier Duval S C 24 EThematekContrasted
Saunier Duval S F 24 EThematekContrasted
Saunier Duval C 24 EAIsotwinContrasted
Saunier Duval C 28 EAIsotwinContrasted
Saunier Duval C 24 E ad04IsotwinContrasted
Saunier Duval C 24 E de04IsotwinContrasted
Saunier Duval F 24 EIsotwinContrasted
Saunier Duval F 24 EAIsotwinContrasted
Saunier Duval F 28 EAIsotwinContrasted
Saunier Duval F 30 E H-MODIsofastContrasted
Saunier Duval F 35 E H-MODIsofastContrasted
Saunier Duval F 25 E STLThemaContrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if ref. S1047000 is the part for your boiler

What determines it is not the boiler model, but the reference printed on the part you already have installed.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference S1047000. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms and faults that the PCB S1047000 resolves.

The PCB controls the ignition, modulation, and safety features of the boiler. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The pump, the fan, or the burner stay on continuously even though the boiler should have turned off.

    Cause: One of the relays on the PCB is stuck and does not open the contact, so the component continues to receive power.

    Listen for the click of the relays when starting and stopping the boiler; if one doesn't make a sound or gets stuck, that's where the fault is before replacing the entire PCB.

  • 02

    The boiler does not start the burner even though the rest of the functions are working normally.

    Cause: The relay that gives the ignition command does not close the contact and the signal does not reach the gas valve.

    Measure with the multimeter if there is continuity in the corresponding relay at the moment the boiler attempts to ignite.

  • 03

    Repeated clicking sounds are heard in the boiler without anything happening.

    Cause: A faulty relay switches several times trying to close the contact without success.

    Locate which relay the noise is coming from (they are identified on the PCB) to confirm which one is faulty before deciding on the replacement.

  • 04

    Different functions gradually stop responding: first the pump, then the fan.

    Cause: The relays degrade one by one with use and fail at different times.

    Note the order in which the components stop functioning; if it coincides with different relays, confirm it before replacing the entire PCB.

Fault codes from Saunier Duval that this spare part resolves.

CodeFaultDiagnosis and solution
F13Main PCB faultYes — it is the direct code of the PCB. Check 230 V, fuse, connectors, and grounding; if it persists, replace the PCB.
F11No signal is reaching the main circuitPossible — first rule out wiring and connectors to the PCB; if they are fine, it is usually the PCB.
F12No signal from the user interfaceNormally not — it's usually the display or its cable, not this main PCB.
F18User interface faultNormally not — it corresponds to the panel/display, not to this PCB.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Data sheet for the Saunier Duval S1047000 PCB.

Catalogue reference
S1047000
Brand
Saunier Duval
Type of part
PCBs (control boards)
Units in stock
1 unit
Status
Refurbished
Warranty
1 year
Shipping
1-2 business days
Return
14 days

Data read on the part and in the manufacturer's documentation

What we have not been able to verify does not appear here.

PCB reference
S1047000
Relays (x3)
OMRON G5Q-1, DC24V, manufactured in China, 5A 30VDC / 10A 250VAC~
Connector plastic classification
UL GF201 94V-0A / GF P/N 2036288A 2
Documentation

Manuals and technical documentation

Official documentation of the boiler, useful for locating the part and cross-referencing the fault codes.

Frequently Asked Questions

Frequently asked questions about the PCB S1047000

Is the PCB Ref. S1047000 suitable for a Saunier Duval Isotwin C 24 E?
Yes, the Isotwin C 24 E is on the list of boilers compatible with this PCB.
What relays are installed on the PCB of the Thema C 25 E?
Three OMRON G5Q-1 relays of 24V DC, with contacts of 5A/30VDC and 10A/250VAC.
When should this PCB of the Thema C 25 E be replaced?
When the PCB stops working, it is a component that is replaced entirely, not repaired.
Is the S1047000 PCB also compatible with a Themaplus C 25 E?
Yes, the Themaplus C 25 E is listed among the models compatible with this PCB.

Spare parts related to Saunier Duval ThemaClassic

Delivery 1–2 daysworking days, mainland Spain
1-year warrantyreviewed and tested
14-day returnuninstalled parts
Technical supportwe verify your model