Saunier Duval Themafast C 28 E Control PCB Ref. S1047000

Saunier Duval Themafast C 28 E Control PCB Ref. S1047000

Stock · 1 unit

When you turn on the tap or start the heating, the Saunier Duval Themafast C 28 E Control PCB Ref. S1047000 is responsible for managing the ignition and modulation of the burner, as well as the operation of the pump and the safety features of the boiler. If it fails, you will notice that the boiler does not start, gets locked, or exhibits erratic behavior, potentially displaying fault codes such as F13, F11, F12, or F18. This PCB is compatible with models from the ThemaClassic, Themafast, Thematek, Isotwin, Isofast, and Thema ranges, among others. It should be replaced when it shows signs of malfunction or when any error related to its operation is detected.

VAT included

Compatibility

Saunier Duval boilers compatible with reference S1047000

PCB with reference S1047000. 33 verified compatibilities: F 25 E and F 24 E.

Proven compatibility

Boiler modelFamilyVerification
Saunier Duval F 25 EThemaClassicContrasted
Saunier Duval F 24 EThemaClassicContrasted
Saunier Duval C 24 EThemaClassicContrasted
Saunier Duval C 25 EThemaClassicContrasted
Saunier Duval C AS 24 EThemaClassicContrasted
Saunier Duval C AS 25 EThemaClassicContrasted
Saunier Duval F AS 24 EThemaClassicContrasted
Saunier Duval F AS 25 EThemaClassicContrasted
Saunier Duval F AS 30 EThemaClassicContrasted
Saunier Duval C 24 EThemafastContrasted
Saunier Duval C 25 EThemafastContrasted
Saunier Duval C 28 EThemafastContrasted
Saunier Duval C 30 EThemafastContrasted
Saunier Duval F 24 EThemafastContrasted
Saunier Duval F 25 EThemafastContrasted
Saunier Duval F 25 E H-MODThemafastContrasted
Saunier Duval F 30 EThemafastContrasted
Saunier Duval F 30 E H-MODThemafastContrasted
Saunier Duval C 24 EThematekContrasted
Saunier Duval C 24 EO BTThematekContrasted
Saunier Duval F 24 EThematekContrasted
Saunier Duval S C 24 EThematekContrasted
Saunier Duval S F 24 EThematekContrasted
Saunier Duval C 24 EAIsotwinContrasted
Saunier Duval C 28 EAIsotwinContrasted
Saunier Duval C 24 E ad04IsotwinContrasted
Saunier Duval C 24 E de04IsotwinContrasted
Saunier Duval F 24 EIsotwinContrasted
Saunier Duval F 24 EAIsotwinContrasted
Saunier Duval F 28 EAIsotwinContrasted
Saunier Duval F 30 E H-MODIsofastContrasted
Saunier Duval F 35 E H-MODIsofastContrasted
Saunier Duval F 25 E STLThemaContrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if ref. S1047000 is the part for your boiler

What determines it is not the boiler model, but the reference printed on the part you already have installed.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference S1047000. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms and faults that the PCB S1047000 resolves.

The PCB controls the ignition, modulation, and safety features of the boiler. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The boiler does not ignite and there are no lights or indications on the control panel.

    Cause: If the fuse of the PCB blows, all the electronics lose power.

    With a multimeter, check if the fuse on the PCB is blown before replacing it; if it is, also check what may have caused it to trip.

  • 02

    The PCB does not respond to the room thermostat or to the buttons on the control panel itself.

    Cause: A fault in the communication of the PCB prevents it from receiving any commands sent.

    Check that the connectors of the remote control and the wiring to the PCB are properly fitted before replacing it.

  • 03

    A fault code from the control board appears on the display and does not disappear after resetting.

    Cause: The PCB locks itself when it detects an internal fault that it cannot resolve on its own.

    Note the exact code: in these series it is usually described in the manual and may indicate a peripheral, not the PCB itself.

  • 04

    The boiler turns off by itself repeatedly without the user doing anything.

    Cause: An intermittent fault in the control board can cause safety shutdowns without any real external cause.

    Keep a record of when the outages occur (with heating, with domestic hot water, during startup) to rule out other components before replacing the PCB.

Fault codes from Saunier Duval that this spare part resolves.

CodeFaultDiagnosis and solution
F13Main PCB faultYes — it is the direct code of the PCB. Check 230 V, fuse, connectors, and grounding; if it persists, replace the PCB.
F11No signal is reaching the main circuitPossible — first rule out wiring and connectors to the PCB; if they are fine, it is usually the PCB.
F12No signal from the user interfaceNormally not — it's usually the display or its cable, not this main PCB.
F18User interface faultNormally not — it corresponds to the panel/display, not to this PCB.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Data sheet for the Saunier Duval S1047000 PCB.

Catalogue reference
S1047000
Brand
Saunier Duval
Type of part
PCBs (control boards)
Units in stock
1 unit
Status
Refurbished
Warranty
1 year
Shipping
Delivery time shown at checkout
Return
14 days

Data read on the part and in the manufacturer's documentation

What we have not been able to verify does not appear here.

Reference (adhesive label)
S1047000
PCB code (silkscreen)
0310144400S20
Manufacturing index
IND 06
Fuse
T630mA / 250V
Silkscreened name on PCB
SYMSI7.0
Plastic regulation (UL)
GF201 94V-0
Documentation

Manuals and technical documentation

Official documentation of the boiler, useful for locating the part and cross-referencing the fault codes.

Frequently Asked Questions

Frequently asked questions about the PCB S1047000

What fuse does the PCB of the Themafast C 28 E use?
A T630mA/250V fuse; the text is small, it's advisable to check it on your unit.
Is the reference S1047000 from the catalog correct for this PCB?
Yes, it is fully and clearly readable on the part's label, and it matches what the store publishes.
Does this PCB work for a Saunier Duval Isofast C 35 EA?
Yes, the Isofast C 35 EA is on the list of compatible boilers for this PCB.
What brand of manufacturing index does this PCB have?
IND 06, according to the brand printed on the PCB.
Does this PCB work for a Saunier Duval Thematek C 24 E in addition to the Themafast?
Yes, the Thematek C 24 E is included in the list of compatible boilers.