If your boiler does not start, locks out, or behaves erratically, you may need the Saunier Duval Themaclassic C 24 E PCB (control board) Ref. S1047000. This control board manages the ignition, burner modulation, pump, and safety features of the boiler. Users may experience fault codes such as F13, F11, F12, or F18 when it fails. It is compatible with models from the ThemaClassic, Themafast, Thematek ranges, among others. It is recommended to replace it when these symptoms or errors occur.

Compatibility

Saunier Duval boilers compatible with reference S1047000

PCB with reference S1047000. 33 verified compatibilities: F 25 E and F 24 E.

Proven compatibility

Boiler modelFamilyVerification
Saunier Duval F 25 EThemaClassicContrasted
Saunier Duval F 24 EThemaClassicContrasted
Saunier Duval C 24 EThemaClassicContrasted
Saunier Duval C 25 EThemaClassicContrasted
Saunier Duval C AS 24 EThemaClassicContrasted
Saunier Duval C AS 25 EThemaClassicContrasted
Saunier Duval F AS 24 EThemaClassicContrasted
Saunier Duval F AS 25 EThemaClassicContrasted
Saunier Duval F AS 30 EThemaClassicContrasted
Saunier Duval C 24 EThemafastContrasted
Saunier Duval C 25 EThemafastContrasted
Saunier Duval C 28 EThemafastContrasted
Saunier Duval C 30 EThemafastContrasted
Saunier Duval F 24 EThemafastContrasted
Saunier Duval F 25 EThemafastContrasted
Saunier Duval F 25 E H-MODThemafastContrasted
Saunier Duval F 30 EThemafastContrasted
Saunier Duval F 30 E H-MODThemafastContrasted
Saunier Duval C 24 EThematekContrasted
Saunier Duval C 24 EO BTThematekContrasted
Saunier Duval F 24 EThematekContrasted
Saunier Duval S C 24 EThematekContrasted
Saunier Duval S F 24 EThematekContrasted
Saunier Duval C 24 EAIsotwinContrasted
Saunier Duval C 28 EAIsotwinContrasted
Saunier Duval C 24 E ad04IsotwinContrasted
Saunier Duval C 24 E de04IsotwinContrasted
Saunier Duval F 24 EIsotwinContrasted
Saunier Duval F 24 EAIsotwinContrasted
Saunier Duval F 28 EAIsotwinContrasted
Saunier Duval F 30 E H-MODIsofastContrasted
Saunier Duval F 35 E H-MODIsofastContrasted
Saunier Duval F 25 E STLThemaContrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if ref. S1047000 is the part for your boiler

What determines it is not the boiler model, but the reference printed on the part you already have installed.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference S1047000. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms and faults that the PCB S1047000 resolves.

The PCB controls the ignition, modulation, and safety features of the boiler. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The boiler does not turn on, there are no lights or display, although there is power in the house.

    Cause: The PCB controls the internal power supply of the boiler; if it fails at its input, it does not supply power to the other components.

    Check if the fuse on the PCB is blown and verify that the boiler is receiving 230V at the input before replacing it.

  • 02

    The boiler turns on and displays a screen, but the pump, the fan, or the gas valve do not work when heat is needed.

    Cause: The PCB has three relays that send the command to those components; if one is damaged, the logic works but the output does not activate.

    With a multimeter, measure if there is voltage at the corresponding output when the boiler requests that component, before considering the PCB as faulty.

  • 03

    The boiler turns off by itself after a few minutes of operation, without a clear pattern.

    Cause: Micro-cuts in the solder joints or traces of the PCB, damaged by heat, generate erratic readings that cause a safety lockout.

    Note if the cut always occurs at the same point in the cycle (start, modulation, stop) before changing the PCB.

  • 04

    The thermostat or the boiler control stops communicating, or does so intermittently.

    Cause: The PCB manages communication with the control; a fault in it can interrupt or distort that communication.

    Check the communication wiring and try connecting the boiler in manual mode to rule out issues with the control before replacing the PCB.

Fault codes from Saunier Duval that this spare part resolves.

CodeFaultDiagnosis and solution
F13Main PCB faultYes — it is the direct code of the PCB. Check 230 V, fuse, connectors, and grounding; if it persists, replace the PCB.
F11No signal is reaching the main circuitPossible — first rule out wiring and connectors to the PCB; if they are fine, it is usually the PCB.
F12No signal from the user interfaceNormally not — it's usually the display or its cable, not this main PCB.
F18User interface faultNormally not — it corresponds to the panel/display, not to this PCB.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Data sheet for the Saunier Duval S1047000 PCB.

Catalogue reference
S1047000
Brand
Saunier Duval
Type of part
PCBs (control boards)
Units in stock
0 units
Status
Refurbished
Warranty
1 year
Shipping
1-2 business days
Return
14 days

Data read on the part and in the manufacturer's documentation

What we have not been able to verify does not appear here.

PCB reference
S1047000
PCB version
SYMSI7.0 / 0310144400S19
Relays (x3)
OMRON G5Q-1, DC24V, 5A 30VDC / 10A 250VAC
Connector plastic classification
UL GF201 94V-0 / GF P/N 2036288A 2
Documentation

Manuals and technical documentation

Official documentation of the boiler, useful for locating the part and cross-referencing the fault codes.

Frequently Asked Questions

Frequently asked questions about the PCB S1047000

What is the reference for the PCB of the Saunier Duval Themaclassic C 24 E?
S1047000, printed on the label and matching the one published today by the store for this item.
What brand are the relays on this PCB?
It has three OMRON G5Q-1 relays of 24V DC, according to its label.
Does this PCB work for a Saunier Duval Themaclassic C 25 E?
Yes, it is on the list of compatible boilers for this PCB.
Is the S1047000 PCB compatible with a Saunier Duval Isotwin F 24 E?
Yes, the Isotwin F 24 E is among the indicated compatible models.

Spare parts related to Saunier Duval ThemaClassic

Delivery 1–2 daysworking days, mainland Spain
1-year warrantyreviewed and tested
14-day returnuninstalled parts
Technical supportwe verify your model
Saunier Duval Themaclassic C 24 E PCB Ref. S1047000