Saunier Duval Themis 23E PCB Ref. 05712800

Saunier Duval Themis 23E PCB Ref. 05712800

The Saunier Duval Themis 23E PCB is the component that controls key functions such as ignition, burner modulation, the pump, and the safety features of the boiler. When it fails, the boiler may not start, become locked, or exhibit erratic operation, displaying faults such as F.28, F.61, F.62, F.63, or F.64. This part is compatible with several models from the Thelia and Themis ranges, among others. A technician must confirm through diagnosis whether replacement is necessary when these symptoms or faults in the boiler's operation are detected.

Catalogue reference
05712800
Warranty
1 year
VAT included Stock · 4 units
Compatibility

Saunier Duval boilers compatible with reference 05712800

PCB with reference 05712800. Three confirmed compatibilities: 23 E and 623 E.

Verified compatibility

Boiler modelFamilyVerification
Saunier Duval 23 ETheliaVerified
Saunier Duval 623 ETheliaVerified
Saunier Duval 23 EThemisVerified

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if ref. 05712800 is the part for your boiler

The part reference, model, and equipment revision must be verified against the manufacturer's documentation.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference 05712800. If it is not visible, do not identify the part by its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms that require diagnosis on the PCB 05712800

The PCB controls the ignition, modulation, and safety features of the boiler. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The boiler shows no signs: no lights, no display, and it doesn't attempt to turn on.

    Cause: The PCB does not activate its control circuit and does not send commands to the other components.

    Check that power is reaching the PCB and that its internal fuse is not blown before replacing it.

  • 02

    An error code appears on the screen that does not clear when restarting.

    Cause: The microprocessor on the PCB detects an incorrect reading and locks the boiler for safety.

    Check the sensor or component related to that specific fault code before considering the PCB as faulty.

  • 03

    The remote control or the thermostat do not control the boiler, as if it is not responding.

    Cause: The PCB manages communication with the remote control, and if its bus controller fails, it does not understand the commands.

    Check the wiring and the bus connectors between the PCB and the control before replacing the PCB.

  • 04

    The boiler turns off by itself intermittently, without a fixed pattern.

    Cause: An occasional fault in the PCB, such as a loose solder joint, causes the loss of a safety signal randomly.

    Check that all the connectors on the PCB are properly tightened and free of rust before replacing it.

Fault codes Saunier Duval that require diagnosis

CodeFaultTechnical checks
F.28Fault: unsuccessful ignition on start-upThe PCB may fail (defective electronics) or have the multi-connector improperly plugged in, preventing ignition management; check power supply and ground connections, continuity of the harness, and seating of the multipin on the PCB before replacing it.
F.61Gas valve activation errorThis symptom may be related to the part, but it does not confirm that it is faulty. A technician must check the equipment and its inspection according to the manual before deciding on a repair or replacement.
F.62Gas valve disconnection delay errorAn electronic fault in the PCB may maintain a delayed shutdown command or late flame detection; check the control signal at the gas valve terminals, and if the shutdown command persists without an external cause, replace the PCB.
F.63EEPROM faultFault in the PCB memory (EEPROM) or data corruption; confirm with resets/auto-test, check for stable voltages, and if the fault persists, replace the PCB.
F.64Electronic fault / NTCThe electronics of the PCB are declared faulty or misinterpret sensors due to an internal error; check sensors/harness and, if they are correct, the cause is the PCB.
F.65Fault: PCB temperatureThe PCB detects overheating or a fault in its internal thermal circuit; check ventilation/environment and temperature in the electronic box, and if it reappears without an external cause, replace the PCB.
F.67Fault: electronics/flameThe ionisation signal is not plausible due to a fault in the flame circuit on the PCB; check the electrode/wiring and, if the signal remains abnormal with correct hardware, the cause is the electronics of the board.
F.70Invalid product code (DSN)The display and/or printed circuit board has been replaced without reconfiguring the product code/DSN; check with the service menu and reprogram the code or, if not possible, replace/configure the correct PCB.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Data sheet for the Saunier Duval 05712800 PCB.

Catalogue reference
05712800
Uniclima internal SKU
PLCTHMS23
Brand
Saunier Duval
Type of part
PCBs (control boards)
Units in stock
4 units
Status
Refurbished
Warranty
1 year
Shipping
Delivery time shown at checkout
Return
14 days

Part data and available documentation

Contrast the label codes, PCB, and revision with the installed part; they are not necessarily equivalent references.

Supply voltage
230V
Fuse
80mA T
Relay, coil voltage
24V DC
Relay, contacts
8A / 250V~ / AC1
PCB code (component side)
8/050151H
Date / manufacturing batch
97/03/08, batch 9720
Documentation

Manuals and technical documentation

Official documentation of the boiler, useful for locating the part and cross-referencing the fault codes.

Frequently asked questions

Frequently asked questions about the PCB 05712800

Does this PCB from the Themis 23E also work for the Thelia 623E?
Yes, it is listed as compatible with Themis 23E, Themis 23EV, Thelia 23E, Thelia 623, and Thelia 623E.
Does the code recorded on the PCB match the reference 05712800?
Not literally; the code 8/050151H is engraved on the PCB.
What voltage does the PCB of the Thelia 623 operate at?
At 230V mains, with an 80 mA T fuse.
What components does this PCB include besides the relay RYA3002A?
A comparator LM393N, an operational amplifier LM358N, and a 10KA potentiometer P1.

Spare parts related to Saunier Duval Thelia

Delivery calculated by destination Delivery time shown at checkout
1-year warranty inspected and tested
14-day return uninstalled parts
Technical support we verify your model
Saunier Duval Themis 23E PCB Ref. 05712800