When you turn on the tap or activate the heating, the Saunier Duval Master Twin L 85 E Ignition Module is responsible for controlling the ignition and modulation of the burner, as well as the pump and safety features of the boiler. If this part fails, you will notice that the boiler does not start, locks out, or exhibits erratic behavior, and you might see the fault codes F.28 or F.29. This module is compatible with boilers from the Thelia Twin, Themis Twin, Thelia, Sylva, and Master Twin ranges, among others. It should be replaced when these ignition or operational issues occur.

VAT included

Compatibility

Saunier Duval boilers compatible with reference 05602400

PCB with reference 05602400. Five confirmed compatibilities: Thelia Twin 28 E and Themis Twin 28 E.

Proven compatibility

Boiler modelFamilyVerification
Saunier Duval Thelia Twin 28 EThelia TwinContrasted
Saunier Duval Themis Twin 28 EThemis TwinContrasted
Saunier Duval Thelia 30 ETheliaContrasted
Saunier Duval Sylva 24 ESylvaContrasted
Saunier Duval Master Twin L 85 EMaster TwinContrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if ref. 05602400 is the part for your boiler

What determines it is not the boiler model, but the reference printed on the part you already have installed.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference 05602400. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms and faults that the PCB 05602400 resolves.

The PCB controls the ignition, modulation, and safety features of the boiler. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The boiler does not ignite the burner when heat is requested.

    Cause: The ignition module is faulty and does not generate a spark, although the rest of the boiler is functioning well.

    Look through the peephole or grille to see if a spark occurs when requesting heat: if you don't see a spark, the module is the main suspect.

  • 02

    Intermittent ignition: sometimes it lights and sometimes it doesn't, with weak spark.

    Cause: The module deteriorates with heat and use, and does not provide enough energy for a constant spark.

    Measure if the fault worsens when the boiler is hot after running for a while: this thermal pattern is typical of the module, not the electrode.

  • 03

    The boiler locks up when trying to start and requests a reset.

    Cause: If the module does not ignite the burner within the safety time, the boiler locks out due to flame detection failure.

    Check the condition of the electrode and its wiring before replacing the module: a loose or poorly connected electrode can cause the same lockout.

Fault codes from Saunier Duval that this spare part resolves.

CodeFaultDiagnosis and solution
F.28Ignition fault of the burnerThe burner does not ignite after five attempts, indicating a problem in the ignition process. This may be due to a fault in the ignition module. Check the gas supply and the condition of the module.
F.29Ignition fault of the burnerThe burner does not ignite after five attempts, indicating a problem in the ignition process. This may be caused by a fault in the ignition module. Make sure that the gas is reaching properly and that the module is functioning correctly.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Data sheet for the Saunier Duval 05602400 PCB.

Catalogue reference
05602400
Brand
Saunier Duval
Type of part
PCBs (control boards)
Units in stock
5 units
Status
Refurbished
Warranty
1 year
Shipping
Delivery time shown at checkout
Return
14 days
Documentation

Manuals and technical documentation

Official documentation of the boiler, useful for locating the part and cross-referencing the fault codes.

Frequently Asked Questions

Frequently asked questions about the PCB 05602400

Is this module valid for my Sylva 24 E?
Yes, it is on the list of compatible boilers along with Master Twin L 85 E, Sylva FF 24 E, Thelia 30 E, Thelia Twin 28 E, and Themis Twin 28 E.
How is this module identified in a Thelia Twin 28 E?
Due to its black plastic with a red clip.
When should the ignition module be replaced in a Thelia 30 E?
When the boiler does not ignite or gets locked due to an ignition fault.