PCB Combitek F 24 E Ref. 735004 V087 C
When you turn on the tap or activate the heating, the Combitek F 24 E PCB Ref. 735004 V087 C is responsible for controlling the ignition and modulation of the burner, as well as the pump and safety features of the boiler. If it fails, you will notice that the boiler does not start, gets locked, or exhibits erratic behavior, potentially displaying faults such as F11, F12, F13, or F18. This board is compatible with boilers from the ThemaClassic, Themafast, Thematek, and Isotwin ranges, among others. It is recommended to replace it when you experience these symptoms or during preventive maintenance.
VAT included
Consult via WhatsAppSaunier Duval boilers compatible with reference S1047000
PCB with reference S1047000. 33 verified compatibilities: F 25 E and F 24 E.
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Saunier Duval F 25 E | ThemaClassic | Contrasted |
| Saunier Duval F 24 E | ThemaClassic | Contrasted |
| Saunier Duval C 24 E | ThemaClassic | Contrasted |
| Saunier Duval C 25 E | ThemaClassic | Contrasted |
| Saunier Duval C AS 24 E | ThemaClassic | Contrasted |
| Saunier Duval C AS 25 E | ThemaClassic | Contrasted |
| Saunier Duval F AS 24 E | ThemaClassic | Contrasted |
| Saunier Duval F AS 25 E | ThemaClassic | Contrasted |
| Saunier Duval F AS 30 E | ThemaClassic | Contrasted |
| Saunier Duval C 24 E | Themafast | Contrasted |
| Saunier Duval C 25 E | Themafast | Contrasted |
| Saunier Duval C 28 E | Themafast | Contrasted |
| Saunier Duval C 30 E | Themafast | Contrasted |
| Saunier Duval F 24 E | Themafast | Contrasted |
| Saunier Duval F 25 E | Themafast | Contrasted |
| Saunier Duval F 25 E H-MOD | Themafast | Contrasted |
| Saunier Duval F 30 E | Themafast | Contrasted |
| Saunier Duval F 30 E H-MOD | Themafast | Contrasted |
| Saunier Duval C 24 E | Thematek | Contrasted |
| Saunier Duval C 24 EO BT | Thematek | Contrasted |
| Saunier Duval F 24 E | Thematek | Contrasted |
| Saunier Duval S C 24 E | Thematek | Contrasted |
| Saunier Duval S F 24 E | Thematek | Contrasted |
| Saunier Duval C 24 EA | Isotwin | Contrasted |
| Saunier Duval C 28 EA | Isotwin | Contrasted |
| Saunier Duval C 24 E ad04 | Isotwin | Contrasted |
| Saunier Duval C 24 E de04 | Isotwin | Contrasted |
| Saunier Duval F 24 E | Isotwin | Contrasted |
| Saunier Duval F 24 EA | Isotwin | Contrasted |
| Saunier Duval F 28 EA | Isotwin | Contrasted |
| Saunier Duval F 30 E H-MOD | Isofast | Contrasted |
| Saunier Duval F 35 E H-MOD | Isofast | Contrasted |
| Saunier Duval F 25 E STL | Thema | Contrasted |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if ref. S1047000 is the part for your boiler
What determines it is not the boiler model, but the reference printed on the part you already have installed.
- Find the reference printed on the installed part and check whether it matches the catalogue reference S1047000. If it is not visible, do not identify the part from its shape alone.
- Check the full boiler model on its data plate and look for it in the model associations on this page.
- Compare the connections and physical body with the original part before installation.
- If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Symptoms and faults that the PCB S1047000 resolves.
The PCB controls the ignition, modulation, and safety features of the boiler. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
The boiler won't start and not a single light turns on, as if it has no power.
Cause: The safety transformer of the PCB is not supplying the necessary current to the rest of the circuit.
Check that the boiler has 230V at the input and that the internal fuse is not blown before replacing the PCB.
- 02
It gets stuck with a fixed fault code and does not respond to resets.
Cause: The PCB interprets a safety signal (flame, pressure, or temperature) out of range and does not release the ignition.
Note the fault code and check the pressure switch and the sensor before considering the PCB as the culprit: they are the most common causes of blockage.
- 03
The pump or the burner does not start even though a click can be heard inside the boiler.
Cause: A relay on the PCB switches but does not properly close the contact that powers the component.
Listen for the click to repeat several times in a row without result: it is a clear indication of a faulty relay on the PCB.
- 04
The boiler works well for a while and then stops on its own, and starts up again without you having touched anything.
Cause: An intermittent fault on the PCB, due to soldering or a component that overheats, disrupts the cycle randomly.
Note after how much time of use it stops: if it coincides with the boiler being hot for a while, it points to a thermal problem with the PCB.
Fault codes from Saunier Duval that this spare part resolves.
| Code | Fault | Diagnosis and solution |
|---|---|---|
| F13 | Main PCB fault | Yes — it is the direct code of the PCB. Check 230 V, fuse, connectors, and grounding; if it persists, replace the PCB. |
| F11 | No signal is reaching the main circuit | Possible — first rule out wiring and connectors to the PCB; if they are fine, it is usually the PCB. |
| F12 | No signal from the user interface | Normally not — it's usually the display or its cable, not this main PCB. |
| F18 | User interface fault | Normally not — it corresponds to the panel/display, not to this PCB. |
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Data sheet for the Saunier Duval S1047000 PCB.
- Catalogue reference
- S1047000
- Brand
- Saunier Duval
- Type of part
- PCBs (control boards)
- Units in stock
- 1 unit
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- 1-2 business days
- Return
- 14 days
Data read on the part and in the manufacturer's documentation
What we have not been able to verify does not appear here.
- Side code of the PCB
- .0 735004 V087 C
- Silkscreened batch/serial code
- 4000 120400/8
- safety transformer
- MYRRA, VDE marked
- Partial barcode
- 4000 120400/8...
Manuals and technical documentation
Official documentation of the boiler, useful for locating the part and cross-referencing the fault codes.
- Saunier Duval S C 24 E Manual (PDF)Document © Saunier Duval, provided as a technical reference.