Saunier Duval Themafast F25 E H-MOD SUNG WEI PCB Ref. S1047000
The Saunier Duval Themafast F25 E H-MOD SUNG WEI PCB is the component that controls the ignition, burner modulation, pump, and safety features of your boiler. When it malfunctions, the boiler may fail to start, become locked, or exhibit erratic behavior. This PCB is compatible with several models, such as the F 25 E, F 24 E, C 24 E, and others from the Themafast and ThemaClassic ranges, among others. It is recommended to replace it when symptoms of malfunction appear to restore the boiler's operability.
VAT included
Consult via WhatsAppSaunier Duval boilers compatible with reference S1047000
PCB with reference S1047000. 33 verified compatibilities: F 25 E and F 24 E.
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Saunier Duval F 25 E | ThemaClassic | Contrasted |
| Saunier Duval F 24 E | ThemaClassic | Contrasted |
| Saunier Duval C 24 E | ThemaClassic | Contrasted |
| Saunier Duval C 25 E | ThemaClassic | Contrasted |
| Saunier Duval C AS 24 E | ThemaClassic | Contrasted |
| Saunier Duval C AS 25 E | ThemaClassic | Contrasted |
| Saunier Duval F AS 24 E | ThemaClassic | Contrasted |
| Saunier Duval F AS 25 E | ThemaClassic | Contrasted |
| Saunier Duval F AS 30 E | ThemaClassic | Contrasted |
| Saunier Duval C 24 E | Themafast | Contrasted |
| Saunier Duval C 25 E | Themafast | Contrasted |
| Saunier Duval C 28 E | Themafast | Contrasted |
| Saunier Duval C 30 E | Themafast | Contrasted |
| Saunier Duval F 24 E | Themafast | Contrasted |
| Saunier Duval F 25 E | Themafast | Contrasted |
| Saunier Duval F 25 E H-MOD | Themafast | Contrasted |
| Saunier Duval F 30 E | Themafast | Contrasted |
| Saunier Duval F 30 E H-MOD | Themafast | Contrasted |
| Saunier Duval C 24 E | Thematek | Contrasted |
| Saunier Duval C 24 EO BT | Thematek | Contrasted |
| Saunier Duval F 24 E | Thematek | Contrasted |
| Saunier Duval S C 24 E | Thematek | Contrasted |
| Saunier Duval S F 24 E | Thematek | Contrasted |
| Saunier Duval C 24 EA | Isotwin | Contrasted |
| Saunier Duval C 28 EA | Isotwin | Contrasted |
| Saunier Duval C 24 E ad04 | Isotwin | Contrasted |
| Saunier Duval C 24 E de04 | Isotwin | Contrasted |
| Saunier Duval F 24 E | Isotwin | Contrasted |
| Saunier Duval F 24 EA | Isotwin | Contrasted |
| Saunier Duval F 28 EA | Isotwin | Contrasted |
| Saunier Duval F 30 E H-MOD | Isofast | Contrasted |
| Saunier Duval F 35 E H-MOD | Isofast | Contrasted |
| Saunier Duval F 25 E STL | Thema | Contrasted |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if ref. S1047000 is the part for your boiler
What determines it is not the boiler model, but the reference printed on the part you already have installed.
- Find the reference printed on the installed part and check whether it matches the catalogue reference S1047000. If it is not visible, do not identify the part from its shape alone.
- Check the full boiler model on its data plate and look for it in the model associations on this page.
- Compare the connections and physical body with the original part before installation.
- If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Symptoms and faults that the PCB S1047000 resolves.
The PCB controls the ignition, modulation, and safety features of the boiler. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
The boiler does not respond to any commands, neither from the panel itself nor from the thermostat.
Cause: The PCB manages the operation of the device; if it fails, it does not process commands.
Check that the thermostat or external control is receiving power before ruling out the PCB.
- 02
The fan starts but the flame never ignites.
Cause: The PCB controls the spark and the gas opening after validating the pre-ventilation; if it fails, there is no flame.
Check that the air pressure switch and the gas valve are functioning separately before replacing the PCB.
- 03
The screen displays a fixed fault code that does not disappear even after resetting.
Cause: A fault in the PCB blocks the security code on the display.
Check the exact code and compare it with the fault list of your model before purchasing the PCB.
- 04
The boiler works for a while and then locks out, and it only resets manually to repeat the process.
Cause: A damaged component in the electronics can cause recurring safety lockouts.
Check the condition of the cables and connectors that reach the PCB, especially those closest to the burner.
Fault codes from Saunier Duval that this spare part resolves.
| Code | Fault | Diagnosis and solution |
|---|---|---|
| F13 | Main PCB fault | Yes — it is the direct code of the PCB. Check 230 V, fuse, connectors, and grounding; if it persists, replace the PCB. |
| F11 | No signal is reaching the main circuit | Possible — first rule out wiring and connectors to the PCB; if they are fine, it is usually the PCB. |
| F12 | No signal from the user interface | Normally not — it's usually the display or its cable, not this main PCB. |
| F18 | User interface fault | Normally not — it corresponds to the panel/display, not to this PCB. |
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Data sheet for the Saunier Duval S1047000 PCB.
- Catalogue reference
- S1047000
- Brand
- Saunier Duval
- Type of part
- PCBs (control boards)
- Units in stock
- 22 pcs
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- 1-2 business days
- Return
- 14 days
Data read on the part and in the manufacturer's documentation
What we have not been able to verify does not appear here.
- Manufacturing code (screen printing)
- 0310144400L12
- PCB/model number
- SYMSI7.0
- Top right corner code (low confidence reading)
- 125872-15 CA0-0543, followed by 'F1'
- Brand printed next to the triangle
- SUNG WEI 06V0-A
- Connectors/terminals
- ZIG, V3V, H5, OU/REMP, H9, P2/P1, H4, uA, EXT, TA, 230V ALIM, 230V
- Fuse (approximate reading)
- T6,3A 250V~
Manuals and technical documentation
Official documentation of the boiler, useful for locating the part and cross-referencing the fault codes.
- Saunier Duval F 35 E H-MOD Manual (PDF)Document © Saunier Duval, provided as a technical reference.