When you turn on the hot water tap or activate the heating, the Saunier Duval Isofast F 35 E H MOD Main PCB is responsible for controlling the ignition, burner modulation, pump, and safety features of the boiler. If this part fails, the boiler may not start, become locked, or exhibit erratic operation, displaying fault codes such as F13, F11, F12, or F18. It is installed in boilers from the Isofast range, among others like the F 30 E H-MOD model. It is advisable to replace it if you notice any of these symptoms to avoid further issues.

VAT included

Compatibility

Saunier Duval boilers compatible with reference S1047000

PCB with reference S1047000. 33 verified compatibilities: F 25 E and F 24 E.

Proven compatibility

Boiler modelFamilyVerification
Saunier Duval F 25 EThemaClassicContrasted
Saunier Duval F 24 EThemaClassicContrasted
Saunier Duval C 24 EThemaClassicContrasted
Saunier Duval C 25 EThemaClassicContrasted
Saunier Duval C AS 24 EThemaClassicContrasted
Saunier Duval C AS 25 EThemaClassicContrasted
Saunier Duval F AS 24 EThemaClassicContrasted
Saunier Duval F AS 25 EThemaClassicContrasted
Saunier Duval F AS 30 EThemaClassicContrasted
Saunier Duval C 24 EThemafastContrasted
Saunier Duval C 25 EThemafastContrasted
Saunier Duval C 28 EThemafastContrasted
Saunier Duval C 30 EThemafastContrasted
Saunier Duval F 24 EThemafastContrasted
Saunier Duval F 25 EThemafastContrasted
Saunier Duval F 25 E H-MODThemafastContrasted
Saunier Duval F 30 EThemafastContrasted
Saunier Duval F 30 E H-MODThemafastContrasted
Saunier Duval C 24 EThematekContrasted
Saunier Duval C 24 EO BTThematekContrasted
Saunier Duval F 24 EThematekContrasted
Saunier Duval S C 24 EThematekContrasted
Saunier Duval S F 24 EThematekContrasted
Saunier Duval C 24 EAIsotwinContrasted
Saunier Duval C 28 EAIsotwinContrasted
Saunier Duval C 24 E ad04IsotwinContrasted
Saunier Duval C 24 E de04IsotwinContrasted
Saunier Duval F 24 EIsotwinContrasted
Saunier Duval F 24 EAIsotwinContrasted
Saunier Duval F 28 EAIsotwinContrasted
Saunier Duval F 30 E H-MODIsofastContrasted
Saunier Duval F 35 E H-MODIsofastContrasted
Saunier Duval F 25 E STLThemaContrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if ref. S1047000 is the part for your boiler

What determines it is not the boiler model, but the reference printed on the part you already have installed.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference S1047000. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms and faults that the PCB S1047000 resolves.

The PCB controls the ignition, modulation, and safety features of the boiler. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The boiler is completely dead: neither the display nor any indicator lights up.

    Cause: The integrated power supply on the PCB may have failed, which distributes current to the rest of the circuits.

    Check with a multimeter that mains power is reaching the PCB and that the fuse is not blown before replacing it.

  • 02

    A communication or bus fault code appears, and the control does not display data from the boiler.

    Cause: The communication circuit of the PCB with the remote control or accessories has been damaged.

    Check the wiring of the bus between the PCB and the control, and test with the boiler in local mode before replacing the PCB.

  • 03

    The water heating or heating system activates inconsistently, as if the boiler is deciding on its own.

    Cause: A relay on the PCB may have stuck, keeping a circuit that should be cut active.

    Listen for the click of the relays when switching and measure if there is current in the component when it should be stopped.

  • 04

    The boiler loses its configuration or programmed parameters after each power outage.

    Cause: The memory of the PCB, or the battery that supports it, may be failing and not retaining the saved data.

    Check if the boiler has a backup battery on the PCB and its condition before replacing the entire assembly.

Fault codes from Saunier Duval that this spare part resolves.

CodeFaultDiagnosis and solution
F13Main PCB faultYes — it is the direct code of the PCB. Check 230 V, fuse, connectors, and grounding; if it persists, replace the PCB.
F11No signal is reaching the main circuitPossible — first rule out wiring and connectors to the PCB; if they are fine, it is usually the PCB.
F12No signal from the user interfaceNormally not — it's usually the display or its cable, not this main PCB.
F18User interface faultNormally not — it corresponds to the panel/display, not to this PCB.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Data sheet for the Saunier Duval S1047000 PCB.

Catalogue reference
S1047000
Brand
Saunier Duval
Type of part
PCBs (control boards)
Units in stock
1 unit
Status
Refurbished
Warranty
1 year
Shipping
Delivery time shown at checkout
Return
14 days

Data read on the part and in the manufacturer's documentation

What we have not been able to verify does not appear here.

PCB code (silkscreened)
SYMSI7.0 / 0310144400S19
Sales reference printed on the plate
S1047000
Relays
OMRON G5Q-1 DC24V, batch 26Y5C4
Plastic certification
UL GF201 94V-0 / GF P/N 2036288A 2
Before purchasing
  • The PCB has a quality control/repair box with the marks SD10024C / WO:513893 / NR:0056. It looks like a workshop ticket, not an original manufacturing data; it may indicate that the unit has been inspected or repaired previously.
Documentation

Manuals and technical documentation

Official documentation of the boiler, useful for locating the part and cross-referencing the fault codes.

Frequently Asked Questions

Frequently asked questions about the PCB S1047000

Is the reference S1047000 for this PCB confirmed for the Isofast F 35 E H-MOD?
Yes, it is printed directly on the PCB, not just in the catalog.
Does this PCB work for my Isotwin C 24 EA?
Yes, it is on the list of compatible models, along with the rest of the Isofast, Isosplit, Isotwin, Thema, and Themaclassic series.
What relays does this PCB of the Isosplit C 28 E have?
Omron G5Q-1 relays.
What are the brands 'SD10024C' and 'WO:513893' that appear on the PCB of the Thema F 25 E?
They seem to be notes from a workshop repair ticket, not original manufacturing data.
When should this main PCB be replaced in the Isofast F 30 E H-MOD?
When the control board fails and the boiler stops functioning properly.