Chaffoteaux Celtic / GM 2.24 RSc PCB Ref. 45216 F
The control PCB governs the ignition, burner modulation, pump, and safety features of the boiler. This part, manufactured by Chaffoteaux and with reference 45216, is essential for the operation of models such as the Celtic 2.24 RSc and the GM 2.24 RSc, among others. If it fails, you will notice that the boiler does not start, locks out, or exhibits erratic behavior, potentially displaying faults such as 3 03 or 40-50-60-70. It is advisable to replace it when you experience these issues, as its malfunction directly affects the performance of the boiler.
VAT included
Consult via WhatsAppChaffoteaux boilers compatible with reference 60045263
PCB with reference 60045263. Four confirmed compatibilities: CELTIC 1.24 RSc and CELTIC 2-24 RSc.
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Chaffoteaux CELTIC 1.24 RSc | Chaffoteaux | Contrasted |
| Chaffoteaux CELTIC 2-24 RSc | Chaffoteaux | Contrasted |
| Chaffoteaux CELTIC 2.24 RSc | Chaffoteaux | Contrasted |
| Chaffoteaux GM 2.24 RSc | Chaffoteaux | Contrasted |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if the part number 60045263 is the one for your boiler
What determines it is not the boiler model, but the reference printed on the part you already have installed.
- Find the reference printed on the installed part and check whether it matches the catalogue reference 60045263. If it is not visible, do not identify the part from its shape alone.
- Check the full boiler model on its data plate and look for it in the model associations on this page.
- Compare the connections and physical body with the original part before installation.
- If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Symptoms and faults that the PCB 60045263 resolves.
The PCB controls the ignition, modulation, and safety features of the boiler. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
The boiler does not ignite, neither the display nor the buttons respond.
Cause: The PCB does not receive or distribute electrical power to the other components.
Check if there is power to the boiler and verify that the internal fuse of the PCB is not blown before considering it unusable.
- 02
An unknown fault code appears on the display or it changes constantly.
Cause: The tracks or memory of the PCB are damaged, causing incorrect readings.
Note the exact code and consult it in the boiler manual before assuming that the PCB is faulty.
- 03
The thermostat or the room control requests heat, but the boiler does not start.
Cause: The PCB does not recognize the demand signal due to a fault in its input.
Directly bridge the terminals of the thermostat on the PCB to check if it starts without the control.
- 04
The boiler resets with the reset button, but the fault reappears immediately.
Cause: The PCB has lost operating parameters or has a permanently damaged internal component.
Count how many resets are necessary and check if the fault occurs at the same point in the cycle before replacing the PCB.
Fault codes Chaffoteaux that this part resolves
| Code | Fault | Diagnosis and solution |
|---|---|---|
| 3 03 | Main PCB fault | Internal fault of the main PCB; the equipment reports it as "Main board error". Check 230 V input, 5/12 V voltages on the board, and fuses in the MC/CF fuse holder; if they are correct, replace the PCB ref. 60045263. |
| 3 05 | Main PCB fault | Internal fault of the main PCB preventing correct control. Check the power supply and logical outputs of the board and fuses; if everything is correct, the repair involves replacing the PCB ref. 60045263. |
| 3 06 | Main PCB fault | Internal anomaly in the main PCB. Check service voltages (5/12 V), continuity of fuses and connectors; if there are no external anomalies, replace the PCB ref. 60045263. |
| 3 07 | Main PCB fault | Main PCB fault detected by self-diagnosis. Confirm that the power supply and outputs of the board are correct and that the fuses in the fuse holder are not open; if everything is fine, replace the PCB ref. 60045263. |
| 40-50-60-70-80 | Communication error PCB boiler | Communication fault with the power PCB; it is usually the PCB itself (ref. 60045263) or its bus. Check the harness and connectors between the interface and PCB, and the 5/12 V voltages; if they are correct, replace the PCB. |
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Data sheet for the Chaffoteaux 60045263 PCB.
- Catalogue reference
- 60045263
- Brand
- Chaffoteaux
- Type of part
- PCBs (control boards)
- Units in stock
- 5 units
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- 1-2 business days
- Return
- 14 days
Data read on the part and in the manufacturer's documentation
What we have not been able to verify does not appear here.
- code printed on PCB
- 45216 F
- secondary code/batch
- STE 89 39
- manufacturer (literal on label)
- Chaffoteaux et Maury