Myrra Chaffoteaux Calydra Comfort 24 FF PCB, reference S1047000. This control PCB manages the ignition, burner modulation, pump, and safety features of the boiler. When faults occur, the boiler may fail to start, lock out, or operate erratically. It is compatible with models Elexia Comfort 24 CF and 24 FF, Calydra Comfort 24 CF, 24 FF, 28 CF, and 28 FF, among others. It should be replaced when errors such as 3 03, 3 05, 3 06, 3 07, or 3 09 are detected, indicating issues with the main board or gas relay.

VAT included

Compatibility

Chaffoteaux boilers compatible with reference 60000571

PCB with reference 60000571. 11 verified compatibilities: 24 CF and 24 FF.

Proven compatibility

Boiler modelFamilyVerification
Chaffoteaux 24 CFELEXIA COMFORTContrasted
Chaffoteaux 24 FFELEXIA COMFORTContrasted
Chaffoteaux 24 CFCALYDRA COMFORTContrasted
Chaffoteaux 24 FFCALYDRA COMFORTContrasted
Chaffoteaux 28 CFCALYDRA COMFORTContrasted
Chaffoteaux 28 FFCALYDRA COMFORTContrasted
Chaffoteaux 24 CFMAYAContrasted
Chaffoteaux 24 FFMAYAContrasted
Chaffoteaux 28 FFMAYAContrasted
Chaffoteaux 24 CFMC2Contrasted
Chaffoteaux 24 FFMC2Contrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if ref. 60000571 is the part for your boiler

What determines it is not the boiler model, but the reference printed on the part you already have installed.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference 60000571. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms and faults that the PCB 60000571 resolves.

The PCB controls the ignition, modulation, and safety features of the boiler. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The boiler does not turn on: there are no lights on even when you request heating.

    Cause: The PCB is not sending current to the control circuits.

    Check the fuse on the PCB and verify that the transformer is supplying power before declaring it faulty.

  • 02

    A different fault code appears each time, without a clear pattern.

    Cause: A component of the PCB fails intermittently before breaking down completely.

    Note the codes and when they appear; if they change without apparent reason, the problem may be in the PCB.

  • 03

    It smells burnt or there are dark marks near the transformer of the PCB.

    Cause: A voltage spike may have damaged the transformer or the components of the power supply stage.

    Visually inspect the PCB for swollen or blackened components before confirming their replacement.

  • 04

    The boiler starts, runs for a while, and then shuts off by itself without locking.

    Cause: The PCB loses the signal from a sensor or a relay and interrupts the cycle for safety.

    Check that the temperature sensors are properly connected to their connectors on the PCB before replacing it.

Fault codes Chaffoteaux that this part resolves

CodeFaultDiagnosis and solution
3 03Main PCB fault.Internal fault of the main PCB (microcontroller/power supply/tracks). Check 230/low-voltage on the board, disconnect peripherals to rule out shorts, and if it persists, replace the PCB ref. 60000571.
3 05Main PCB fault.Anomaly detected by the main PCB electronics. Check 5/12 V power supply, connectors, and continuity; if the fault reappears without external loads, the PCB is faulty.
3 06Main PCB fault.PCB fault (e.g., damaged regulation/logical stage). Confirm there are no shorts in sensors/actuators and measure stable voltages on the board; if it persists, replace the 60000571.
3 07Main PCB fault.Recurrent internal fault of the PCB. After checking wiring and peripherals, if the error returns on startup or after reset, the cause is the main board.
3 09Gas relay fault (on PCB).The gas valve relay integrated into the PCB does not switch/close correctly. Check the ignition control and voltage to the valve during demand; if there is no output despite the command, replace the PCB 60000571.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Data sheet for the PCB Chaffoteaux 60000571

Catalogue reference
60000571
Brand
Chaffoteaux
Type of part
PCBs (control boards)
Units in stock
1 unit
Status
Refurbished
Warranty
1 year
Shipping
1-2 business days
Return
14 days

Data read on the part and in the manufacturer's documentation

What we have not been able to verify does not appear here.

voltage
230V
frequency
50Hz
capacitor
10uF
Frequently Asked Questions

Frequently asked questions about the PCB 60000571

Is this PCB suitable for the Elexia Comfort 24 CF?