Delta Dore Display PCB for Aludra Delta / Mira Comfort / Mira Green / Niagara Green - Ref. 1317990
RefurbishedChaffoteauxPCBs (control boards)Delta Dore

Delta Dore Display PCB for Aludra Delta / Mira Comfort / Mira Green / Niagara Green - Ref. 1317990

Stock · 1 unit

Display board for Aludra Delta, Mira Comfort, Mira Green, and Niagara Green boilers. The manufacturer is listed on the label of the same part: Delta Dore, reference 1317990, revision V1.10, and batch 06-36. The circuit has the code 7164021 T30 printed on it. It is replaced when the display does not turn on, does not show digits, or the controls stop responding.

VAT included

Compatibility

Chaffoteaux boilers compatible with reference 60000486

PCB with reference 60000486. 11 verified compatibilities: DELTA 24 FF and DELTA 28 FF.

Proven compatibility

Boiler modelFamilyVerification
Chaffoteaux DELTA 24 FFALUDRAContrasted
Chaffoteaux DELTA 28 FFALUDRAContrasted
Chaffoteaux COMFORT 24 FFLOOKContrasted
Chaffoteaux COMFORT 30 FFLOOKContrasted
Chaffoteaux GREEN 24 FFLOOKContrasted
Chaffoteaux GREEN 30 FFLOOKContrasted
Chaffoteaux GREEN 35 FFLOOKContrasted
Chaffoteaux GREEN SYSTEM 24 FFLOOKContrasted
Chaffoteaux GREEN SYSTEM 30 FFLOOKContrasted
Chaffoteaux GREEN SYSTEM 35 FFLOOKContrasted
Chaffoteaux GREEN 24NIAGARAContrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if ref. 60000486 is the part for your boiler

What determines it is not the boiler model, but the reference printed on the part you already have installed.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference 60000486. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms and faults that the PCB 60000486 resolves.

The PCB controls the ignition, modulation, and safety features of the boiler. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The display does not turn on and the boiler appears to be off from the outside, although it is still functioning.

    Cause: This PCB controls the display, which is the only visible part; if it fails, you won't see anything even though the boiler remains operational.

    Listen to see if the boiler ignites the burner or the pump when requesting heating, even if you don't see anything on the screen; that indicates that the problem is only with the display.

  • 02

    The display shows a blank screen or stripes instead of numbers.

    Cause: The display module may deteriorate over time and stop displaying characters correctly, even if it receives power.

    Check if the problem occurs consistently or only when the boiler has been on for a while and heats up, as this suggests a thermal fault of the display.

  • 03

    The buttons on the panel do not respond when pressed.

    Cause: This PCB controls both the screen and the buttons, so an internal fault can cause the controls to be unresponsive even though the display remains on.

    Test several different buttons to ensure that it is not just one that is failing, but the entire PCB.

  • 04

    The screen turns off and on by itself intermittently.

    Cause: An internal power supply issue on the display PCB can cause restarts that appear as flickering or blackouts.

    Check that the connector linking this PCB to the main one is not loose; a poor connection can produce the same symptom without the PCB being damaged.

Fault codes Chaffoteaux that this part resolves

CodeFaultDiagnosis and solution
40-50-60-70-80Communication problem with the boiler display.The boiler's display is not communicating with the main PCB. It could be a fault in the display or in the cables connecting them. Check that the display is receiving 5 V and is properly grounded. Inspect that the communication cables are not damaged. If it still doesn't work, try replacing the display with another one of the same type, reference 60000486.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Data sheet for the PCB Chaffoteaux 60000486

Catalogue reference
60000486
Brand
Chaffoteaux
Type of part
PCBs (control boards)
Units in stock
1 unit
Status
Refurbished
Warranty
1 year
Shipping
1-2 business days
Return
14 days

Data read on the part and in the manufacturer's documentation

What we have not been able to verify does not appear here.

Component manufacturer
Delta Dore
Reference code (Delta Dore)
1317990
Index / review
V1.10
Batch code/date
06-36
Code printed on PCB
7164021 T30
Frequently Asked Questions

Frequently asked questions about the PCB 60000486

Is the display board ref. 1317990 an original Delta Dore?
The manufacturer listed on the part's label is Delta Dore, with the same reference (1317990).
Does this PCB work for the Saunier Duval MX2 Comfort?
No, the MX2 Comfort is not listed among the compatible boilers, although the current catalog mentions it in another section of the data sheet.
Does this PCB fit the Mira Green System 30 FF?
Yes, it is on the list of compatible boilers, along with the rest of the Mira Green System range.
What PCB revision does the Aludra Delta 24 FF have?
The label indicates index/revision V1.10, batch 06-36.

Spare parts related to Chaffoteaux MIRA

Delivery 1–2 daysworking days, mainland Spain
1-year warrantyreviewed and tested
14-day returnuninstalled parts
Technical supportwe verify your model
Delta Dore Display PCB for Aludra Delta / Mira Comfort / Mira Green / Niagara Green - Ref. 1317990