Chaffoteaux PCB MC 23 CF / Ref. 61010100
Control PCB mounted in Chaffoteaux boilers from the MC 23 CF, MC 23 CFP, Nectra 2.23 CFP, and Siam 2.23 ranges. It operates at 230V, according to the PCB's labeling. It is the boiler's control board; it is replaced in case of electronic errors, startup failure, or loss of functions without a mechanical cause.
VAT included
Consult via WhatsAppChaffoteaux boilers compatible with reference 61010100
PCB with reference 61010100. Nine confirmed compatibilities: MC 23 CF and MC CF 24.
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Chaffoteaux MC 23 CF | MC CF | Contrasted |
| Chaffoteaux MC CF 24 | MC CF | Contrasted |
| Chaffoteaux MC CF 28 | MC CF | Contrasted |
| Chaffoteaux MC CFP | MC CF | Contrasted |
| Chaffoteaux Siam 2.23 CF | Siam CF | Contrasted |
| Chaffoteaux Siam 2-23 E CF | Siam CF | Contrasted |
| Chaffoteaux Nectra 2.23 CF | Nectra CF | Contrasted |
| Chaffoteaux Nectra 2.23 CFP | Nectra CF | Contrasted |
| Chaffoteaux Nectra Top 2.23 CF | Nectra CF | Contrasted |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if ref. 61010100 is the part for your boiler
What determines it is not the boiler model, but the reference printed on the part you already have installed.
- Find the reference printed on the installed part and check whether it matches the catalogue reference 61010100. If it is not visible, do not identify the part from its shape alone.
- Check the full boiler model on its data plate and look for it in the model associations on this page.
- Compare the connections and physical body with the original part before installation.
- If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Symptoms and faults that the PCB 61010100 resolves.
The PCB controls the ignition, modulation, and safety features of the boiler. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
The boiler turns on, makes an attempt, and shuts off after a few seconds.
Cause: The PCB does not maintain the flame or safety signal, and the control unit cuts off the ignition command.
Before replacing the PCB, check that gas is reaching the unit and that the electrode or nearby pressure switch is not dirty, because sometimes the fault disappears after ruling this out.
- 02
The display or the boiler's indicator lights are completely off, not a single LED is on.
Cause: A fault in the power supply stage of the PCB leaves the rest of the system without power.
Check that mains voltage is reaching the boiler and that the visible fuse on the PCB is not blown before replacing it.
- 03
The control or thermostat is not responding: it changes the temperature but the boiler does not comply.
Cause: The PCB has lost communication with the thermostat due to a fault in its control circuit.
Try resetting the thermostat and check the connection wiring before assuming the PCB is the cause.
- 04
Different fault codes appear every few days, without a clear pattern.
Cause: Electronic components on the PCB fail intermittently and generate erroneous sensor readings.
Note each code and the time it appears: if they are always different and unrelated to usage, it points more towards the PCB than a specific component.
Fault codes Chaffoteaux that this part resolves
| Code | Fault | Diagnosis and solution |
|---|---|---|
| 3 03 | Main PCB fault. | The PCB fails in its self-diagnosis (EEPROM/microcontroller/power supply). Check 230 V input and low voltages 5/12 V on the PCB; if it persists with peripherals disconnected, replace the PCB. |
| 3 05 | Main PCB fault. | Internal defect in the PCB detected by self-diagnosis. Check power supply, grounding, and settings on the PCB; if the voltages are incorrect or the fault reappears after reset, the cause is the PCB. |
| 3 06 | Main PCB fault. | Internal anomaly of the PCB (components/regulators). Measure 5 V/12 V, check BUS/IDC connectors and isolate loads; if with minimal wiring the fault persists, the PCB is faulty. |
| 3 07 | Main PCB fault. | Persistent hardware fault on the control board. Check voltages, fuses, tracks/relays and retest with peripherals disconnected; if it persists, replace the board. |
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Data sheet for the Chaffoteaux 61010100 PCB.
- Catalogue reference
- 61010100
- Brand
- Chaffoteaux
- Type of part
- PCBs (control boards)
- Units in stock
- 1 unit
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- 1-2 business days
- Return
- 14 days
Data read on the part and in the manufacturer's documentation
What we have not been able to verify does not appear here.
- supply voltage
- 230V
Manuals and technical documentation
Official documentation of the boiler, useful for locating the part and cross-referencing the fault codes.
- Chaffoteaux Nectra Top 2.23 CF Manual (PDF)Document © Chaffoteaux, provided as a technical reference.