Chaffoteaux PCB MC 2 24 FF Ref. 60000571
The Chaffoteaux MC 2 24 FF PCB, with reference 60000571, is the component responsible for controlling the ignition, burner modulation, pump, and safety features of the boiler. When it malfunctions, the boiler may fail to start, become locked, or operate erratically, displaying faults such as 3 03, 3 05, 3 06, 3 07, or 3 09. This PCB is compatible with boilers from the ELEXIA COMFORT, CALYDRA COMFORT, MAYA, and MC2 ranges, among others. It is recommended to replace it upon detecting these symptoms to restore the proper functioning of the boiler.
VAT included
Consult via WhatsAppChaffoteaux boilers compatible with reference 60000571
PCB with reference 60000571. 11 verified compatibilities: 24 CF and 24 FF.
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Chaffoteaux 24 CF | ELEXIA COMFORT | Contrasted |
| Chaffoteaux 24 FF | ELEXIA COMFORT | Contrasted |
| Chaffoteaux 24 CF | CALYDRA COMFORT | Contrasted |
| Chaffoteaux 24 FF | CALYDRA COMFORT | Contrasted |
| Chaffoteaux 28 CF | CALYDRA COMFORT | Contrasted |
| Chaffoteaux 28 FF | CALYDRA COMFORT | Contrasted |
| Chaffoteaux 24 CF | MAYA | Contrasted |
| Chaffoteaux 24 FF | MAYA | Contrasted |
| Chaffoteaux 28 FF | MAYA | Contrasted |
| Chaffoteaux 24 CF | MC2 | Contrasted |
| Chaffoteaux 24 FF | MC2 | Contrasted |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if ref. 60000571 is the part for your boiler
What determines it is not the boiler model, but the reference printed on the part you already have installed.
- Find the reference printed on the installed part and check whether it matches the catalogue reference 60000571. If it is not visible, do not identify the part from its shape alone.
- Check the full boiler model on its data plate and look for it in the model associations on this page.
- Compare the connections and physical body with the original part before installation.
- If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Symptoms and faults that the PCB 60000571 resolves.
The PCB controls the ignition, modulation, and safety features of the boiler. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
The boiler does not turn on, there are no lights or display, it seems that it is not receiving power.
Cause: If the input stage of the PCB fails, power is not distributed to the electronics, and nothing works.
Check the fuse on the PCB and measure the voltage at its input connector before considering it faulty.
- 02
A different fault code appears each time, or the same one disappears on its own without a clear pattern.
Cause: An internal fault in the PCB can give erroneous readings from a sensor, even if the sensor is functioning properly.
Measure with a multimeter the sensor that indicates the fault code before replacing the PCB.
- 03
The fuse blows again as soon as a new one is installed.
Cause: A fuse that repeatedly blows usually indicates a short circuit in the PCB or in a powered component.
Before installing another fuse, disconnect the pump, the valve, and the fan one by one to see if the short circuit is outside the PCB.
- 04
The boiler ignites, runs for a while, and then shuts off by itself, repeating the cycle.
Cause: A output relay that opens prematurely cuts off the power supply to a component during its operation.
Check which component stops receiving current just before it turns off to identify which output of the PCB is faulty.
Fault codes Chaffoteaux that this part resolves
| Code | Fault | Diagnosis and solution |
|---|---|---|
| 3 03 | Main PCB fault. | Internal fault of the main PCB (microcontroller/power supply/tracks). Check 230/low-voltage on the board, disconnect peripherals to rule out shorts, and if it persists, replace the PCB ref. 60000571. |
| 3 05 | Main PCB fault. | Anomaly detected by the main PCB electronics. Check 5/12 V power supply, connectors, and continuity; if the fault reappears without external loads, the PCB is faulty. |
| 3 06 | Main PCB fault. | PCB fault (e.g., damaged regulation/logical stage). Confirm there are no shorts in sensors/actuators and measure stable voltages on the board; if it persists, replace the 60000571. |
| 3 07 | Main PCB fault. | Recurrent internal fault of the PCB. After checking wiring and peripherals, if the error returns on startup or after reset, the cause is the main board. |
| 3 09 | Gas relay fault (on PCB). | The gas valve relay integrated into the PCB does not switch/close correctly. Check the ignition control and voltage to the valve during demand; if there is no output despite the command, replace the PCB 60000571. |
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Data sheet for the PCB Chaffoteaux 60000571
- Catalogue reference
- 60000571
- Brand
- Chaffoteaux
- Type of part
- PCBs (control boards)
- Units in stock
- 1 unit
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- Delivery time shown at checkout
- Return
- 14 days
Data read on the part and in the manufacturer's documentation
What we have not been able to verify does not appear here.
- Transformer brand
- was
- Conformity marking
- CE