Chaffoteaux Elexia Comfort 24FF PCB Ref. 60000571
The Chaffoteaux Elexia Comfort boilers use the Chaffoteaux Elexia Comfort 24FF PCB (control board) Ref. 60000571. This control board manages the ignition, burner modulation, pump, and safety features of the boiler. If it fails, you may notice that the boiler does not start, locks out, or operates erratically, displaying faults such as 3 03 or 3 09. It is compatible with models from the Elexia Comfort, Calydra Comfort, and Maya ranges, among others. It is recommended to replace it when these symptoms or faults in operation are detected.
VAT included
Consult via WhatsAppChaffoteaux boilers compatible with reference 60000571
PCB with reference 60000571. 11 verified compatibilities: 24 CF and 24 FF.
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Chaffoteaux 24 CF | ELEXIA COMFORT | Contrasted |
| Chaffoteaux 24 FF | ELEXIA COMFORT | Contrasted |
| Chaffoteaux 24 CF | CALYDRA COMFORT | Contrasted |
| Chaffoteaux 24 FF | CALYDRA COMFORT | Contrasted |
| Chaffoteaux 28 CF | CALYDRA COMFORT | Contrasted |
| Chaffoteaux 28 FF | CALYDRA COMFORT | Contrasted |
| Chaffoteaux 24 CF | MAYA | Contrasted |
| Chaffoteaux 24 FF | MAYA | Contrasted |
| Chaffoteaux 28 FF | MAYA | Contrasted |
| Chaffoteaux 24 CF | MC2 | Contrasted |
| Chaffoteaux 24 FF | MC2 | Contrasted |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if ref. 60000571 is the part for your boiler
What determines it is not the boiler model, but the reference printed on the part you already have installed.
- Find the reference printed on the installed part and check whether it matches the catalogue reference 60000571. If it is not visible, do not identify the part from its shape alone.
- Check the full boiler model on its data plate and look for it in the model associations on this page.
- Compare the connections and physical body with the original part before installation.
- If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Symptoms and faults that the PCB 60000571 resolves.
The PCB controls the ignition, modulation, and safety features of the boiler. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
The boiler is unresponsive: there are no lights or display on.
Cause: The PCB is not sending current to the control circuits, so the unit does not start.
Before replacing it, measure the T125mA and T2A fuses on the PCB with a multimeter: if they are blown, it could just be that.
- 02
The boiler briefly turns on and then shuts off by itself, entering safety mode.
Cause: The PCB detects a safety fault (flame, pressure switch, sensor) and stops the cycle before completing it.
Check the ignition/ionization electrode and its wiring before declaring the PCB faulty.
- 03
The fault code on the panel changes or blinks without a clear pattern.
Cause: The control electronics incorrectly interpret the signals from the connected sensors and generate inconsistent readings.
Note the exact code and reset one or two times to see if the fault is constant or intermittent.
- 04
The remote control or the thermostat do not work with the boiler.
Cause: The PCB manages communication with the control unit, and if that circuit fails, the unit does not respond to commands.
Check the wiring and the connection terminals of the control unit before replacing the complete PCB.
- 05
The relay click is heard, but the pump or the valve does not activate.
Cause: The output relay on the PCB does not close the contact properly, and current does not reach the component.
With the multimeter in continuity mode, check if the relay closes when it should before replacing the PCB.
Fault codes Chaffoteaux that this part resolves
| Code | Fault | Diagnosis and solution |
|---|---|---|
| 3 03 | Main PCB fault. | Internal fault of the main PCB (microcontroller/power supply/tracks). Check 230/low-voltage on the board, disconnect peripherals to rule out shorts, and if it persists, replace the PCB ref. 60000571. |
| 3 05 | Main PCB fault. | Anomaly detected by the main PCB electronics. Check 5/12 V power supply, connectors, and continuity; if the fault reappears without external loads, the PCB is faulty. |
| 3 06 | Main PCB fault. | PCB fault (e.g., damaged regulation/logical stage). Confirm there are no shorts in sensors/actuators and measure stable voltages on the board; if it persists, replace the 60000571. |
| 3 07 | Main PCB fault. | Recurrent internal fault of the PCB. After checking wiring and peripherals, if the error returns on startup or after reset, the cause is the main board. |
| 3 09 | Gas relay fault (on PCB). | The gas valve relay integrated into the PCB does not switch/close correctly. Check the ignition control and voltage to the valve during demand; if there is no output despite the command, replace the PCB 60000571. |
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Data sheet for the PCB Chaffoteaux 60000571
- Catalogue reference
- 60000571
- Brand
- Chaffoteaux
- Type of part
- PCBs (control boards)
- Units in stock
- 1 unit
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- Delivery time shown at checkout
- Return
- 14 days
Data read on the part and in the manufacturer's documentation
What we have not been able to verify does not appear here.
- Fuses on the PCB
- T125mA and T2A