Saunier Duval Thema F 23 E PCB Ref. 05741000
The control PCB of the Saunier Duval Thema F 23 E manages the ignition, burner modulation, pump, and safety features of the boiler. When it fails, the boiler may not start, become locked, or exhibit erratic behavior. It is compatible with the models Thema C 23 E, Thema F 23 E, Thema C AS 23 E, Thema F AS 23 E, Themaplus C 23 E, Themaplus F 23 E, and Combitek C 23 E and F 23 E, among others. It should be replaced upon noticing these malfunction symptoms.
VAT included
Consult via WhatsAppSaunier Duval boilers compatible with reference 05741000
PCB with reference 05741000. Eight confirmed compatibilities: C 23 E and F 23 E.
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Saunier Duval C 23 E | Thema | Contrasted |
| Saunier Duval F 23 E | Thema | Contrasted |
| Saunier Duval C AS 23 E | Thema | Contrasted |
| Saunier Duval F AS 23 E | Thema | Contrasted |
| Saunier Duval C 23 E | Themaplus | Contrasted |
| Saunier Duval F 23 E | Themaplus | Contrasted |
| Saunier Duval C 23 E | Combitek | Contrasted |
| Saunier Duval F 23 E | Combitek | Contrasted |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if ref. 05741000 is the part for your boiler
What determines it is not the boiler model, but the reference printed on the part you already have installed.
- Find the reference printed on the installed part and check whether it matches the catalogue reference 05741000. If it is not visible, do not identify the part from its shape alone.
- Check the full boiler model on its data plate and look for it in the model associations on this page.
- Compare the connections and physical body with the original part before installation.
- If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Symptoms and faults that the PCB 05741000 resolves.
The PCB controls the ignition, modulation, and safety features of the boiler. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
There are no signs of life: no lights or display, the boiler seems to be unplugged.
Cause: The PCB is not receiving power to supply its control circuits.
Check the main fuse and measure with a multimeter that there are stable 230V at the input of the PCB.
- 02
An error code appears that repeats when trying to reset.
Cause: The PCB detects a persistent fault in a sensor or a safety device and locks the equipment.
Note the code and first discard the component indicated (pressure switch, sensor, flame) before replacing the PCB.
- 03
The boiler turns on by itself without anyone requesting heat, or it does not respond when heat is requested.
Cause: Fault in the part of the PCB that manages the heating demand signal.
Check that the room thermostat and its wiring are functioning properly by testing in direct bridge mode if possible.
- 04
The lights or the display flicker without reason or remain fixed in a strange pattern.
Cause: Fault in the power supply to the control electronics of the PCB.
Check that the mains voltage to the boiler is stable and there are no micro-cuts before blaming the PCB.
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Data sheet for the Saunier Duval 05741000 PCB.
- Catalogue reference
- 05741000
- Brand
- Saunier Duval
- Type of part
- PCBs (control boards)
- Units in stock
- 1 unit
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- 1-2 business days
- Return
- 14 days
Data read on the part and in the manufacturer's documentation
What we have not been able to verify does not appear here.
- Supply voltage
- 230 V
- CE code
- CE PIN 0063AT1128
- Main PCB code
- 109042/F
- Auxiliary PCB code
- 356081200
- Transformer
- T28-0438, TUV Class E EN61558, primary 24V~ 50/60Hz (1-5), secondary 48V~ 0.05VA (8-10)
- Logic chip 1
- HCTA07FD 0112998
- Logic chip 2
- AM3748IMBT-154SP 9301QD