PCB Tifell Eurofell MLC15 Ref. CKEOTM15
Eurofell presents the Tifell Eurofell MLC15 PCB Ref. CKEOTM15, which acts as the brain of the boiler, controlling the ignition, burner modulation, pump, and safety features. If this part fails, you will notice that the boiler does not start, locks out, or behaves erratically. It is compatible with models such as MLC15 and TFV-5, among others. It is recommended to replace it if you experience these symptoms or if the boiler shows irregularities in its operation.
VAT included
Consult via WhatsAppCompatible Tifell boilers
PCB. Two confirmed compatibilities: MLC15 and TFV-5.
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Tifell MLC15 | EUROFELL | Contrasted |
| Tifell TFV-5 | TFV-5 | Contrasted |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if it is the part for your boiler
What determines it is not the boiler model, but the reference printed on the part you already have installed.
- Find the reference printed on the installed part and check whether it matches the catalogue reference —. If it is not visible, do not identify the part by its shape alone.
- Check the full boiler model on its data plate and look for it in the model associations on this page.
- Compare the connections and physical body with the original part before installation.
- If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Symptoms and faults that the PCB (control board) resolves
The PCB controls the ignition, modulation, and safety features of the boiler. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
The boiler shows no signs of life when turned on.
Cause: Without the control board, power does not reach the rest of the control circuits.
Check that the boiler is receiving power and that the main switch is turned on.
- 02
The wall thermostat is unable to start the boiler.
Cause: The PCB is the one that receives the command from the thermostat and translates it into ignition; if that part fails, there is no response.
Check that the wiring between the thermostat and the boiler is properly connected and that the thermostat has batteries if it is wireless.
- 03
The boiler turns on and off by itself several times in a row.
Cause: A relay on the PCB that is poorly controlled activates and shuts off the burner without corresponding to a real demand.
Rule out that the thermostat is continuously calling for heat before suspecting the PCB.
- 04
It provides hot water but does not heat the heating system, or vice versa.
Cause: The PCB manages each circuit through a separate output and can only fail one of the two.
Test each function separately to confirm that the fault is in only one of them before replacing the PCB.
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Tifell PCB data sheet
- Brand
- Tifell
- Type of part
- PCBs (control boards)
- Units in stock
- 1 unit
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- Delivery time shown at checkout
- Return
- 14 days
Data read on the part and in the manufacturer's documentation
What we have not been able to verify does not appear here.
- Integrated circuit
- CTIF5.5
- Manufacturing date
- 04/00
- Silkscreen logo on the PCB
- TIFELL