PCB Tifell Eurofell MLC15
The Tifell Eurofell MLC15 PCB, with reference CKVOTP30, is a component that controls the ignition, burner modulation, pump, and safety features of the boiler. If it malfunctions, the boiler may fail to start, become locked, or operate erratically. This part is compatible with models such as Eurofell MLC15, Reducnox MLC15, and TRP 20-50, among others. A technician should confirm through diagnosis whether it needs to be replaced upon noticing these symptoms to avoid further issues.
- Type of part
- PCBs (control boards)
- Status
- Refurbished
- Catalogue reference
- CKE0CE15
- Warranty
- 1 year
Tifell boilers compatible with reference CKE0CE15
PCB with reference CKE0CE15. Three confirmed compatibilities: Eurofell MLC15 and Reducnox MLC15.
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Tifell Eurofell MLC15 | Eurofell MLC15 / Reducnox | Contrasted |
| Tifell Reducnox MLC15 | Eurofell MLC15 / Reducnox | Contrasted |
| Tifell TRP 20-50 | TRP | Contrasted |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if the part CKE0CE15 is the one for your boiler
The part reference, model, and equipment revision must be verified against the manufacturer's documentation.
- Find the reference printed on the installed part and check whether it matches the catalogue reference CKE0CE15. If it is not visible, do not identify the part from its shape alone.
- Check the full boiler model on its data plate and look for it in the model associations on this page.
- Compare the connections and physical body with the original part before installation.
- If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Symptoms that require diagnosis on the PCB CKE0CE15
The PCB controls the ignition, modulation, and safety features of the boiler. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
The boiler does not ignite and there is no sound of any attempt to start.
Cause: The PCB does not send the necessary signal, so the fan and gas valve do not activate, and there is no spark or noise.
Check if the boiler is receiving power and verify that no fuses or circuit breakers have tripped before replacing the PCB.
- 02
The controls are unresponsive and nothing happens when pressed.
Cause: The control electronics translate pulses into commands; if it fails, the panel does not respond even if it is in good condition.
Turn off and reconnect the power to the boiler from the main switch and wait a minute: if the problem returns immediately, it may be the PCB.
- 03
The boiler works for a while and then locks itself, repeatedly.
Cause: Intermittent lockouts are often caused by components on the PCB that fail due to heat or usage.
Note how often the blockage occurs and if it coincides with a higher demand for heating: this information helps to differentiate a PCB fault from a problem in another component.
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Data sheet for the Tifell CKE0CE15 PCB.
- Catalogue reference
- CKE0CE15
- Uniclima internal SKU
- PLCTFLL24
- Brand
- Tifell
- Type of part
- PCBs (control boards)
- Units in stock
- 0 units
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- Delivery time shown at checkout
- Return
- 14 days
Part data and available documentation
Contrast the label codes, PCB, and revision with the installed part; they are not necessarily equivalent references.
- Printed logo on the PCB
- TIFELL
- Main integrated circuit code
- CTIF5.0