Riello M008F PCB for Beretta Super Kompact 24 CSI
Application for the exact variant pending confirmation. Main control PCB of the boiler.
- Type of part
- PCBs (control boards)
- Status
- Refurbished
- internal SKU
- PLC400
- Warranty
- 1 year
Riello compatible boilers
PCB. 0 verified compatibilities. There are 2 other models that we are still checking.
Models pending verification
These models are associated with this reference, but we have not finished verifying them yet, so we do not consider them compatibleIf your boiler is one of them, send us a photo of the part you are going to replace and we will verify it before you purchase.
| Riello Beretta Kompact 24 CSI | Riello | Unconfirmed |
|---|---|---|
| Riello Beretta Super Kompact 24 CSI | Riello | Unconfirmed |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if it is the part for your boiler
The part reference, model, and equipment revision must be verified against the manufacturer's documentation.
- Look for the marking M008F (Riello) on the PCB. The sample also shows FW01.2 on the integrated circuit and the printed fuse FUSE1 T2AL250V.
- Compare the markings of the transformer: A048B5136GA and B59880-C120-A70. They are component markings, not the reference of the PCB.
- Do not equate the M008F and the CP02N2 R10022426 that is for the Super Kompakt 24 CSI, nor the AB05X or AB05B from the Kompact 24: without additional confirmation, they are treated as equal. The display 20011443 is another part.
- Check the data plate of your boiler to confirm that it is a Beretta Super Kompact 24 CSI.
- if they match, call us at 911 17 77 77 with the model of your boiler. Any questions? Send us a photo of the label of your part and the data plate of the boiler from Contact.
Symptoms that require diagnosis on the PCB
The PCB controls the ignition, modulation, and safety features of the boiler. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
The boiler locks out without flame when starting (A01).
Cause: The flame does not stay lit when igniting: gas valve closed or ignition electrodes.
Check that the gas valve is open. If it happens again, have a technician check it. Do not touch the gas.
- 02
The boiler locks out due to a faulty sensor (domestic hot water or heating).
Cause: NTC sensor open or short-circuited.
Have a technician check or replace the sensor.
- 03
The flame on the display goes out, a flashing fault code appears, and the boiler stops heating.
Cause: Safety lock due to lack of flame after ignition.
Reset once. If it repeats, have a technician check it.
- 04
The boiler locks with a fault code from 50 to 59 and does not restart after resetting.
Cause: Fault of the electronic card (PCB).
Have a technician check it.
Riello fault codes that require diagnosis
| Code | Fault | Technical checks |
|---|---|---|
| A01 | Lockout due to flame failure during ignition. | Check that the gas valve is open. If it occurs again, have a technician check it. |
| A06 | Domestic hot water NTC sensor faulty or short-circuited. | Have a technician check or replace the sensor. |
| A07 | Heating NTC sensor faulty or short-circuited. | Have a technician check or replace the sensor. |
| 10 | Flame failure: the boiler does not detect a flame after ignition and shuts down. | If fault code 10 resets, have a technician check it: it could be the PCB, the ignition, or the gas. |
| 11 | Flame detection fault: the boiler detects flame with the burner off. | If fault code 11 appears with the burner off, have a technician check it. |
| 71 | Heating flow sensor (primary circuit). Temporary fault of the sensor. | If fault code 71 appears, have a technician check the supply sensor and its connection. |
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Technical sheet: Riello PCB
- Uniclima internal SKU
- PLC400
- Brand
- Riello
- Type of part
- PCBs (control boards)
- Units in stock
- 1 unit
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- Delivery time shown at checkout
- Return
- 14 days
Part data and available documentation
Contrast the label codes, PCB, and revision with the installed part; they are not necessarily equivalent references.
- FUSE1 printed
- T2AL250V
- Inventory — Finder relay 43.41.7.024.2000
- 24 V⎓; 10 A / 250 V~
- Inventory — Tyco Schrack Relay RY210024
- 24 V⎓; 10 A / 250 VA~
- Inventory — EPCOS mounted component
- 2 × 5.6 mH; 250 V~
- Inventory — PCB
- 94V-0
- Inventory — Application indicated in inventory
- BERETTA SUPER KOMPACT 24 CSI
- Inventory — Transformer marking
- A048B5136GA; B59880-C120-A70
- Identification — Marked designation
- M008F
- Identification — Marked code
- M008F
- Identification — Marked code
- FW01.2
- Identification — Marked code
- A048B5136GA
- Identification — Marked code
- B59880-C120-A70
- FUSE1 screen printed
- T2AL250V
- Inventory data — Finder relay 43.41.7.024.2000
- 24 V⎓; 10 A / 250 V~
- Inventory data — Tyco Schrack relay RY210024
- 24 V⎓; 10 A / 250 VA~
- Inventory data — EPCOS mounted component
- 2 × 5.6 mH; 250 V~
- Inventory data — PCB
- 94V-0
- Inventory data — Application indicated in inventory
- BERETTA SUPER KOMPACT 24 CSI
- Inventory data — Transformer marking
- A048B5136GA; B59880-C120-A70
- Additional markings
- M008F board. FUSE1 transcribed as T4AL/250 V; silkscreen FUSE1: T2AL250V. Finder relay 43.41.7.024.2000: coil 24 V⎓; contacts 10 A/250 V~. Tyco Schrack relay RY210024: coil 24 V⎓; contacts 10 A/250 VA~. EPCOS inductor: 2 × 5.6 mH; marked 250 V~. PCB 94V-0; IC FW01.2; transformer marked A048B5136GA and B59880-C120-A70.
- Pending applications to verify
- BERETTA SUPER KOMPACT 24 CSI — compatibility noted; pending confirmation by variant.
- To confirm: Beretta Kompact 24 CSI: thread of (2021) that cites M008F on its PCB; without "Super", it does not appear to be the same model.
- Do not confuse: R10022426 · CP02N2 — Beretta CP02N2 management PCB (formerly R10022200) that is Italian for the Super Kompakt 24 CSI (1100353):, with an identical copy in — It is not stated that it is the same PCB: those sheets do not mention M008F nor say that it is equivalent. Confirmation recorded: the M008F for this boiler.
- Do not confuse: AB05X / ABO5B / AB05B — AB05X is read by a user on the motherboard of a Kompact 24 CSI and ABO5B is only found online; the AB05B board for the "Kompact 24" — without additional confirmation, they are equated to M008F: compare the full marking.
- Do not confuse: M008F (Fantini) — Article code for a Fantini bidet mixer, LAMÉ series — The code matches, but it is not a PCB: the technical manual from Fantini (hosted) does not mention boilers.
- Do not confuse: 20011443 — Display of the Beretta Kompact 24 CSI in spare parts — It is the screen, not the PCB: its technical sheet does not mention M008F.
- Do not confuse: A048B5136GA · B59880-C120-A70 — from components list A048B5136GA with the manufacturer "ELECTRON COIL" and a distributor B59880-C120-A70 as PTC thermistor from TDK Epcos — These are component numbers: they can be found on the transformer of this PCB, which is searched by M008F.
- A048B5136GA and B59880-C120-A70 are markings of the transformer, not the reference of the PCB. The code of the PCB is M008F.
- Registered identity and compatibility. Outside, a single external source (a thread) cites M008F on a Beretta PCB, it provides for this boiler the PCB CP02N2 R10022426 (ex R10022200); repeat its same technical sheet.
- Pending registered applications to confirm by model, variant, or programming: Beretta Super Kompact 24 CSI.