Bertelli & Partners HDIMS08-SA01 PCB · BI1995100 for Biasi M95 24
Application for the exact variant pending confirmation. It is the control board of the boiler: spare parts classify it as ignition and modulation board.
- Type of part
- PCBs (control boards)
- Status
- Refurbished
- internal SKU
- PLC284
- Warranty
- 1 year
Savio Biasi compatible boilers
PCB. 0 verified compatibilities. There are another 6 models that we are still checking.
Models pending verification
These models are associated with this reference, but we have not finished verifying them yet, so we do not consider them compatibleIf your boiler is one of them, send us a photo of the part you are going to replace and we will verify it before you purchase.
| Savio Biasi Biasi 924 and 928 (SA/ED, SAA/ED, SV/ED, SVA/ED) | Savio Biasi | Unconfirmed |
|---|---|---|
| Savio Biasi Biasi M296.24 and M296.28 (SA/EDY, SAX, SV/EDY, SVX) | Savio Biasi | Unconfirmed |
| Savio Biasi Biasi Super Evo, Super Evo Due and Super Evo Tre | Savio Biasi | Unconfirmed |
| Savio Biasi Biasi Parva Low NOx M95.28 CM/BD, Micronew Evo 824/828, Parva Comfort M90 and Parva Helix M91 | Savio Biasi | Unconfirmed |
| Savio Biasi Biasi M95 24 | Savio Biasi | Unconfirmed |
| Savio Biasi Biasi Parva Recupera (M96A) | Savio Biasi | Unconfirmed |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if it is the part for your boiler
The part reference, model, and equipment revision must be verified against the manufacturer's documentation.
- Find the reference printed on the installed part and check whether it matches the catalogue reference —. If it is not visible, do not identify the part by its shape alone.
- Check the full boiler model on its data plate and look for it in the model associations on this page.
- Compare the connections and physical body with the original part before installation.
- If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Symptoms that require diagnosis on the PCB
The PCB controls the ignition, modulation, and safety features of the boiler. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
The boiler locks without igniting and shows E01.
Cause: Safety lock due to ignition failure.
Press the reset once. If it repeats, have it checked by an authorized technician.
- 02
The display shows E06, E07, or E08 (NTC sensors).
Cause: NTC sensor faulty or no signal.
Have a technician check it.
- 03
The boiler locks and displays E09 or E10 (flue sensor).
Cause: The smoke safety sensor is activated.
Press the reset once. If it repeats, have it checked by an authorized technician.
- 04
The display shows E11 (parasitic flame).
Cause: Flame detected without the boiler having ignited it.
Have a technician check it.
- 05
The boiler does not ignite and shows E01.
Cause: No flame detected during startup.
Reset once. If it repeats, have a technician check it.
- 06
The boiler shows a sensor fault code (E06, E07, or E08).
Cause: NTC sensor for heating, domestic hot water or outdoor, or its connection.
Have a technician check it.
- 07
The boiler shows E11 (parasitic flame).
Cause: The electronics detect flame when it shouldn't.
Have a technician check it.
Fault codes Savio Biasi that require diagnosis
| Code | Fault | Technical checks |
|---|---|---|
| E01 | Safety lock: the boiler has failed to ignite. | If it repeats after resetting, it points to the ignition or the PCB. Have a technician check it. |
| E02 | The safety thermostat has activated and the boiler has locked out. | Reset once. If it repeats, have a technician check it. |
| E06 | Fault of the heating NTC sensor. | If the sensor and its cable are in good condition, it points to the PCB. Have a technician check it. |
| E07 | Fault of the domestic hot water NTC sensor. | Have a technician check it. If the sensor continues to malfunction, it points to the PCB. |
| E08 | Fault of the external NTC sensor. | It only appears with an external sensor configured. Have a technician check it. |
| E09 | Fault of the flue gas NTC sensor (interruption). | Have a technician check it. It is a safety sensor for the flue. |
| E10 | Lockout due to intervention of the flue sensor. | If it repeats, have it checked by an authorized technician. |
| E11 | Flame detected when the boiler should not have one. | Have a technician check it. Focus on the flame electronics. |
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Technical sheet: Savio Biasi PCB
- Uniclima internal SKU
- PLC284
- Brand
- Savio Biasi
- Type of part
- PCBs (control boards)
- Units in stock
- 3 units
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- Delivery time shown at checkout
- Return
- 14 days
Part data and available documentation
Contrast the label codes, PCB, and revision with the installed part; they are not necessarily equivalent references.
- marked supply
- 230V/50Hz
- literal Ta and Ts fields
- Ta:2 Ts:10; units not indicated on label
- marked record
- Reg.CE 51BT3617
- nominal of the filter
- 1.2A/250V; 2x10mH
- Inventory — Indicated reference
- BI1995100
- Inventory — Subcomponent Schaffner filter RN214-1,2/02
- 1.2 A / 250 V; 2 × 10 mH
- Inventory — Schaffner FN 2090-1-02 filter subcomponent
- 1 A / 250 V; 2 A / 125 V
- Inventory — Application indicated in inventory
- M95 24
- Inventory — Marked code
- 4712230L1749; 16874.04; 14064.1195.4; wk50/12 2871749
- Identification — Marked designation
- HDIMS08-SA01
- Identification — Marked code
- 4712230L1749
- Identification — Marked code
- HDIMS08
- Identification — Marked code
- 16874.04
- Identification — Marked code
- 14064.1195.4
- Identification — Marked code
- wk50/12 2871749
- Identification — Marked code
- RN214-1,2/02
- Technical sheet: marked supply
- 230V/50Hz
- Technical sheet: Ta and Ts fields literal
- Ta:2 Ts:10; units not indicated on label
- Technical sheet: marked record
- Reg.CE 51BT3617
- Technical sheet: nominal of the filter
- 1.2A/250V; 2x10mH
- Inventory data — Indicated reference
- BI1995100
- Inventory data — Subcomponent Schaffner RN214-1,2/02 filter
- 1.2 A / 250 V; 2 × 10 mH
- Inventory data — Subcomponent Schaffner FN 2090-1-02 filter
- 1 A / 250 V; 2 A / 125 V
- Inventory data — Application indicated in inventory
- M95 24
- Inventory data — Marked code
- 4712230L1749; 16874.04; 14064.1195.4; wk50/12 2871749
- Additional markings
- Ta: 2; Ts: 10 (units not specified). CE registration: 51BT3617. Schaffner filter RN214-1,2/02: 1.2 A / 250 V; 2 × 10 mH. Schaffner filter FN 2090-1-02: 1 A / 250 V and 2 A / 125 V. Codes: 4712230L1749; 16874.04; 14064.1195.4; wk50/12 2871749. PCB marking: HDIMS08.
- Pending applications to verify
- M95 24 — compatibility noted; pending confirmation by variant. Declarations from (documentation 23/10/2026; revision 24/10/2026), pending confirmation by manufacturer. Check reference, revision, and serial number before use: 924SA/ED · 928SA/ED · 924SAA/ED · 928SAA/ED · 924SV/ED · 928SV/ED · 924SVA/ED · 928SVA/ED · M296.24SA/EDY · M296.28SA/EDY · M296.24SAX · M296.28SAX · M96A.24SM/BD · M96A.28SM/BD · M96A.24SM/BDY
- To confirm: Biasi 924 and 928 (SA/ED, SAA/ED, SV/ED, SVA/ED):
- To confirm: Biasi M296.24 and M296.28 (SA/EDY, SAX, SV/EDY, SVX):
- Biasi Super Evo, Super Evo Due and Super Evo Tre
- To confirm: Biasi Parva Low NOx M95.28 CM/BD, Micronew Evo 824/828, Parva Comfort M90, and Parva Helix M91: (after registration control)
- Not compatible or excluded: Biasi New Nox M95.24 CM/E and CM/EX, Acquamax, Acta 624-632 and Telepiù 724/728 — they are given with the BI2015100, not with the BI1995100.
- Do not confuse: BI2015100 — HDIMS08-SA01 PCB with another Biasi reference (formerly BI1805106) — for Acquamax, Acta, Telepiù, and New Nox M95.24 CM/E and CM/EX. Ours is BI1995100.
- The designation HDIMS08-SA01 is also sold under the reference Biasi BI2015100, for other boilers. Always compare with the Biasi reference. It gives 16874.09 and 14064.1195.6 as brands of the HDIMS08-SA01; they do not match those on our registered label.
- HDIMS08-SA01 connected to BI1995100 by at least independent; M95.24 with BI1995100 in 3. No official breakdown; the designation is shared with BI2015100.
- Pending confirmation of registered applications by model, variant, or programming: Biasi M95 24; Biasi Parva Recupera (M96A).