CEZA FSECZ355P2 PCB · 14064.1190.1 for Biasi Malia 28E
Application to the exact variant pending confirmation. It is the PCB that regulates the boiler. card, main board, and ignition board of type CEZA ST7 or regulation PCB. It is suspected if the boiler does not start or ignite and the fuse, connections, and sensors are fine.
- Type of part
- PCBs (control boards)
- Status
- Refurbished
- internal SKU
- PLC327
- Warranty
- 1 year
Biasi boilers compatible
PCB. 0 verified compatibilities. There are another 11 models that we are still checking.
Models pending verification
These models are associated with this reference, but we have not finished verifying them yet, so we do not consider them compatibleIf your boiler is one of them, send us a photo of the part you are going to replace and we will verify it before you purchase.
| Biasi Malia 24E | Biasi | Unconfirmed |
|---|---|---|
| Biasi Manaut Contract 3 Stelle M90.24CM/F and M90.28CM/F (since 05/2006) | Biasi | Unconfirmed |
| Biasi Manaut Nova Parva / Super Parva / Parva Externa M90.24A (since 11/2006) | Biasi | Unconfirmed |
| Biasi Manaut Minox 3 28E, Minox 3 24E and Minox 24-28 A/E (since 09/2006) | Biasi | Unconfirmed |
| Biasi Savio Biasi M94.24CM and M94.28CM (after 2006) | Biasi | Unconfirmed |
| Biasi Malia 28E | Biasi | Unconfirmed |
| Biasi Manaut Contract M90B.24A (since 11/2006) | Biasi | Unconfirmed |
| Biasi Manaut Contract M90B.28A (since 11/2006) | Biasi | Unconfirmed |
| Biasi Riva Compact M90E | Biasi | Unconfirmed |
| Biasi Riva Plus M90D | Biasi | Unconfirmed |
| Biasi Garda M90F | Biasi | Unconfirmed |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if it is the part for your boiler
The part reference, model, and equipment revision must be verified against the manufacturer's documentation.
- Look for the code 14064.1190.1 and the designation FSECZ355P2 on the PCB. The circuit also includes M800109 and ECSWS355V6.
- Compare with the references: BI1885101 (Manaut and Biasi) and M800109. Do not confuse it with BI1305101 (Riva Compact M96E) or BI1475114 (PCB "main" of the Garda).
- Look at the model on the rating plate of your boiler: the Malia 28E is registered; compare the codes with another model.
- if they match, call us at 911 17 77 77 with your boiler model and we will reserve it for you.
Symptoms that require diagnosis on the PCB
The PCB controls the ignition, modulation, and safety features of the boiler. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
The boiler does not start or ignite.
Cause: Faulty PCB, when the fuse, connections, and sensors are fine.
Check the fuse, the connections, and the sensors. If everything is in order, compare the codes on your PCB with those on this one and consult us.
- 02
06E, 07E or 08E appears: anomaly in an NTC sensor.
Cause: Heating, domestic or outdoor NTC sensor faulty or with defective wiring.
Have a technician check the sensor and its connection.
- 03
The boiler does not ignite and locks with fault code E01.
Cause: Flame not detected on startup: gas fault, ignition fault, or electrode fault.
Reset once. If it repeats, have a technician check it.
- 04
The boiler locks with E11 even when the burner is off.
Cause: Flame sensor: the ionization electrode, its cable, or the plate detect flame.
Have a technician check the electrode, cable, and PCB.
- 05
The E03 fault code reappears after resetting the boiler.
Cause: Internal fault of the PCB or wiring.
Reset and observe. If it returns, have a technician check it: wiring and then the PCB.
- 06
The boiler is locking with E06, E07, or E08 and the temperature displayed is not reliable.
Cause: NTC sensor faulty, or with connector or cable in poor condition.
Have a technician check the connector, cable, and sensor.
- 07
The boiler locks with E22: there is a flame even though the gas valve is closed.
Cause: Call present after closing the gas valve: fault of the PCB or the gas valve.
It is a security alarm: have a technician check it as soon as possible.
- 08
The boiler does not ignite and the pilot indicates a burner ignition fault.
Cause: Ignition fault: it may be due to lack of gas, insufficient spark, or faulty electrodes.
Check that gas is arriving with pressure, that there is a spark, and that the electrodes are in good condition. If everything is fine, have a technician check it before replacing the PCB.
Fault codes Manaut / Biasi that require diagnosis
| Code | Fault | Technical checks |
|---|---|---|
| 01E | Lockout due to burner ignition fault. | Press the reset button once. If it locks again, have a technician check it: it is usually the ignition or flame detection electrode, and then the gas valve. |
| 06E | NTC sensor anomaly in heating. | Have a technician check the heating sensor and its connection. |
| 07E | Anomaly of the NTC sensor for domestic hot water. | Have a technician check the domestic hot water sensor and its connection. |
| 08E | Anomaly of the external NTC sensor. | Have a technician check the external sensor and its wiring. |
| E01 | Safety lock due to ignition failure: flame not detected at startup. | Reset once. If it repeats, have a technician check: gas, electrode, ignition cable, and PCB. |
| E02 | Lockout due to activation of the safety thermostat, due to overheating. | Check for water circulation and bleed the air. If it repeats, have a technician check it. |
| E03 | Generic lock: internal fault without specific detail. | Reset and observe. If it returns, have a technician check it: it points to the PCB and the wiring. |
| E06 | Fault of the heating NTC sensor (flow). | Have a technician check it: connector, cable, and sensor. Point to the sensor if the cable is fine. |
| E07 | Fault of the NTC sensor for domestic hot water. | Have a technician check it: connector, cable, and domestic hot water sensor. Unstable hot water points to the sensor. |
| E08 | Fault of the external NTC sensor. It only affects if an external sensor is installed. | Have a technician check the cable and external sensor. |
| E11 | Flame detection fault: the boiler detects flame with the burner off. | Have a technician check: ionization electrode, cable, and PCB. |
| E12 | Fault of the return heating NTC sensor. | Have a technician check it: connector, cable, and sensor. The return reading is not reliable. |
| E19 | Anomaly of the domestic hot water inlet sensor. | Have a technician check it: connector and domestic hot water sensor. |
| E20 | Gas valve blockage due to pilot valve control hardware failure. | Reset and check if it returns. If it persists, have a technician check it: it is usually the PCB. |
| E21 | Gas valve blockage due to control relay failure of the valve. | It cannot be fixed in the field: have a technician check it. It points to the PCB. |
| E22 | Presence of flame after closing the gas valve. | It is a security alarm: have a technician check it as soon as possible. It points to the PCB or the gas valve. |
| Fault code 01 | Burner ignition fault. | Check that gas is arriving with pressure, that there is a spark, and that the electrodes are in good condition. An ignition fault is not always the PCB: have it checked by a technician. The manual for the model does not use this number: it indicates the fault with a warning light. |
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Technical sheet: PCB (control board) Biasi
- Uniclima internal SKU
- PLC327
- Brand
- Biasi
- Type of part
- PCBs (control boards)
- Units in stock
- 3 units
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- Delivery time shown at checkout
- Return
- 14 days
Part data and available documentation
Contrast the label codes, PCB, and revision with the installed part; they are not necessarily equivalent references.
- type and marked supply
- Type BC 230V/50Hz
- conformity marking
- CE 0051
- Inventory — Indicated reference
- M800109; 14064.1190.1
- Inventory — Type
- BC; marked supply: 230 V/50 Hz
- Inventory — Application indicated in inventory
- MANAUT MALIA 28E
- Inventory — Marked code
- 14064.1190.1; 42/2013; 044192; 12408005 20/12; ETPCW0002; 1015
- Inventory — PCB Marking
- M800109; ECSWS355V6
- Data of — Type of PCB
- CEZA ST7 · main and ignition
- Identification — Marked designation
- FSECZ355P2
- Identification — Marked code
- 14064.1190.1
- Identification — Marked code
- 42/2013
- Identification — Marked code
- 044192
- Identification — Marked code
- M800109
- Identification — Marked code
- ECSWS355V6
- Identification — Marked code
- 12408005 20/12
- Identification — Marked code
- ETPCW0002
- Identification — Marked code
- 1015
- Technical sheet: type and marked power supply
- Type BC 230V/50Hz
- Technical sheet: conformity marking
- CE 0051
- Inventory data — Indicated reference
- M800109; 14064.1190.1
- Inventory data — Type
- BC; marked supply: 230 V/50 Hz
- Inventory data — Application indicated in inventory
- MANAUT MALIA 28E
- Inventory data — Marked code
- 14064.1190.1; 42/2013; 044192; 12408005 20/12; ETPCW0002; 1015
- Inventory data — PCB marking
- M800109; ECSWS355V6
- Pending applications to verify
- Existing transcription in "Compatibilities"; it has not been documented in this update and should not be treated as verified compatibility: Biasi MALIA 28E
- Biasi Malia 24E: (Malia 24E with 1 PCB)
- To confirm: Biasi Contract 3 Stelle M90.24CM/F and M90.28CM/F (since 05/2006):
- To confirm: Biasi Nova Parva / Super Parva / Parva Externa M90.24A (since 11/2006):
- To confirm: Biasi M9024S, Manaut Minox 3 28E, Minox 3 24E, and Minox 24-28 A/E (since 09/2006):
- To confirm: Savio Biasi M94.24CM and M94.28CM (after 2006):
- Not compatible or excluded at source: Biasi Riva Compact M96E (24S, 28S, and 32S) — It uses a different ignition PCB: BI1305101 (Bertelli),
- Do not confuse: BI1475114 — PCB "main" of the Biasi Garda M90F — Another code: list it separately from BI1885101. Compare it.
- Compare the 14064.1190.1 or the M800109: Not confirmed: the designation FSECZ355P2.
- To confirm: 14064.1190.1 and BI1885101: . M800109 and BI1885101: . No official breakdown. The names vary (card, main board and ignition board, regulation PCB). Malia 28E: confirms it.
- Pending registered applications to confirm by model, variant, or programming: Manaut Malia 28E; Manaut Contract M90B.24A (since 11/2006); Manaut Contract M90B.28A (since 11/2006); Biasi Riva Compact M90E; Biasi Riva Plus M90D; Biasi Garda M90F.