Saunier Duval PCB Control Semia Condens F 25 A 1 Ref. 0010028087

Saunier Duval PCB Control Semia Condens F 25 A 1 Ref. 0010028087

80 €VAT includedIn stock · 1 unit

PCB (control board): refurbished spare part that controls the ignition, modulation, and safety features of the boiler. Useful if the boiler does not ignite, locks out, or the display is unresponsive. Compatible with F25, F25 A1, AS 25 A (ref. 0010028087). Includes a one-year warranty and delivery within 2–4 working days in the EU.

1
Consult via WhatsApp
Delivery in 2–4 working days
1-year warranty
14-day return
Technical support

Key Data

Reference
0010028087
Brand
Saunier Duval
Type of part
PCBs (control boards)
Available units
1 unit in stock
Status
Refurbished
Warranty
1 year
Shipping
2–4 working days (EU)
Return
14 days

The same part (ref. 0010028087) equips these models. Verified compatibility; check the reference before purchasing.

Thema Condens

  • F25
  • F25 A1
  • AS 25 A
  • 25-A
  • 25-A R2
  • 30-A

Themafast Condens

  • F25
  • F30 A1
  • 25-A
  • 30-A

Semia Condens

  • F25

Hermann

  • Micra Plus Condens 25

Fault codes related to this part (not the entire boiler). They usually have more possible causes: first rule out electrodes, wiring/connections, and gas supply. Verified with ≥3 sources.

CodeWhat does it mean?Cause and diagnosis (this part)
F.63EEPROM fault.The EEPROM memory of the main PCB is damaged/corrupted; if NTCs and wiring are correct, the cause is the PCB. Check voltages and, if it persists, reprogram/replace the PCB.
F.64Fault in the electronics / NTC.If the NTC sensors and their wiring do not present shorts or inversion, the fault is in the PCB electronics (measurement/processing stage). Check NTCs and continuity; if okay, replace the PCB.
F.65Fault: electronics temperature.The PCB detects overheating or its internal sensor/power stage is faulty. Check ventilation/temperature and dissipation; if everything is correct, the cause is the PCB.
F.67Fault: electronics/flame.The flame detection/control circuit on the PCB is not plausible or defective. Check the ionisation signal and grounding; if they are correct, replace the PCB.
F.70Invalid product code (DSN).After replacing the display and PCB without readjusting the DSN or with incorrect coding resistance, the PCB locks the equipment. Verify/adjust DSN and resistance; if not accepted, incorrect/defective PCB.
F.32Fault: fan.When the motor and wiring are fine, the fault may be with the PCB (multiple connector on PCB, output/driver, or PWM control). Check the power/signal from the PCB to the fan; if there is no correct output, replace the PCB.
How do I confirm that this PCB is the correct one for my boiler?
Check the silkscreened reference 0010028087 on your PCB and ensure that your boiler model is on the list of compatible ones; also compare the number and position of the connectors.
Which models is this PCB suitable for?
It is a PCB shared by several models of the same range (see Compatibility tab). If your model does not appear, send us a photo of the silkscreen and we will confirm it.
When installing it, do you need to parameterize or configure anything?
If you replace it with the same reference, it is usually sufficient to replicate the jumpers/configuration of the original; after installation, a technician should verify service parameters (type of gas, power settings) and check combustion and safety features.
Is it the same as the display or control panel?
No. This is the main PCB (controls ignition, modulation, sensor readings, and safety features). The display/user interface is a separate piece; if your fault is with the panel, it is not this PCB.
Why does a PCB fault occur and how can I prevent the new one from failing?
It is usually due to external causes: voltage spikes, shorts in the pump, fan, or valves, humidity, or poor grounding. Before installing the new one, check peripherals, wiring, and connectors, fix water leaks, and verify polarity and grounding.
What does refurbished mean and what coverage does it have?
Part removed from an out-of-service boiler, inspected and bench-tested; not factory new. Includes 1-year warranty and 14-day return policy. Delivery within 2–4 working days in the EU.

Related Spare Parts Boiler Semia Condens F 25 A 1

Scroll to the top