Boilers · Community of Madrid

Boilers: repair, maintenance, and installation

Multibrand technical service for gas and biomass boilers in Madrid and the Community. We repair faults, perform maintenance in accordance with RITE, and replace old boilers with condensing units with all certificates.

Boiler technical service in Madrid
Boiler repair

Boiler repair

Fault detected, diagnosis during visit and repair on the same day when the necessary parts are available. Multi-brand technical service for wall-hung combination boilers, heating-only boilers, and floor-standing boilers.

  • Diagnosis of fault codes (Saunier Duval, Vaillant, Junkers, Baxi Roca, Ferroli, Ariston…)
  • Replacement of PCBs, fans, NTC sensors, and expansion vessel
  • Repair of water leaks, pressure switches, and chemical cleaning of heat exchanger
View repair service

Boiler maintenance

Inspection in accordance with RITE: combustion analysis, leak tightness verification, and cleaning of the main components. Maintains the manufacturer's warranty and home insurance coverage.

  • Combustion analysis with certified analyser (CO, CO₂, O₂, efficiency)
  • Cleaning of burner, heat exchanger, and filters
  • Pressure check, expansion vessel, and leak test
View maintenance service
Boiler maintenance
Installation and replacement of boilers

Installation and replacement of boilers

Replacement of old boilers with condensing or low NOx class 6 equipment in accordance with current ErP regulations. Includes adaptation of flue, installation registration, and certification by an authorised IG-B installer.

  • Preliminary study of power and evacuation compatibility
  • Flue adaptation to condensation (PVC) and condensate drainage
  • Installation certificate, leak test, and communication to the distributor
View installation service
Types

Types of boilers we repair and install

Condensation

The mandatory typology in replacements with facade exhaust. Utilises the latent heat of the flue gases: efficiency over LCV of 90-93% and energy class A. Flue gas outlet in PVC and condensate drain.

Gas combi

Heating and domestic hot water with a single unit. The most common option in apartments. Instantaneous DHW via plate heat exchanger or bithermal heat exchanger.

Low NOx class 6

Complies with current ErP regulations. It is used when facade evacuation with condensation is not possible: non-condensing outlet, maintains high efficiency.

Biomass

Pellet, olive stone, or wood chip. Requires a technical room and silo. Common solution in chalets and rural areas; not suitable for urban apartments.

Brands

Boiler brands we repair

Multibrand technical service for wall-mounted and floor-standing units, both combination and heating-only. We maintain a permanent stock of spare parts for the most common brands in the Spanish market.

Saunier Duval Vaillant Junkers Bosch Baxi Ferroli Beretta Ariston Cointra Domusa Baxi Roca Biasi Immergas Chaffoteaux Buderus Worcester
Coverage

Areas where we repair boilers

Service in Madrid city, Corredor del Henares, west, north, and south of the Community. Each area with a certified technician in IG-B category for gas.

Corredor del Henares

Torrejón de Ardoz Alcalá de Henares Coslada San Fernando de Henares Mejorada del Campo Velilla de San Antonio Paracuellos de Jarama Loeches

Madrid districts

Centre Salamanca Chamberí Chamartín Withdrawal Hortaleza Moncloa-Aravaca Tetuan

West and North Madrid

Pozuelo de Alarcón Las Rozas Majadahonda Boadilla del Monte Alcobendas San Sebastián de los Reyes Tres Cantos Torrelodones

South and southeast Madrid

Rivas-Vaciamadrid Arganda del Rey Leganés Alcorcón Móstoles Vicálvaro Villa de Vallecas Puente de Vallecas
FAQs

Frequently Asked Questions about Boilers

How often should gas boiler maintenance be performed?

The RITE establishes a mandatory inspection every two years for gas boilers with a power output of less than 70 kW. Insurers and manufacturers often require annual maintenance to maintain warranty and claims coverage, so the usual practice is an annual inspection.

What is the difference between a condensing boiler and a low NOx boiler?

The condensing boiler harnesses the latent heat of the flue gases and achieves efficiencies over 90-93% PCS, with energy class A. The low NOx class 6 boiler maintains similar efficiencies but with less heat recovery; it is used when facade evacuation installation is not possible.

Can my old atmospheric boiler still be repaired?

As long as there are spare parts available in the market, it can be maintained, but when replacing it, the new one must comply with the current ErP regulations: condensation or low NOx class 6 depending on the type of flue.

What does the fault code displayed mean?

Each manufacturer has its own table. The most common ones indicate ignition fault, lack of pressure, NTC sensor, fan, or pressure switch. The technician interprets the code with the service manual and rules out the root cause before replacing parts.

Is the combi boiler providing lukewarm or intermittent water, what could it be?

In combi boilers with plate heat exchangers, it is usually a blockage due to limescale. The usual treatment is chemical cleaning of the heat exchanger. If the issue persists after cleaning, the heat exchanger may be damaged and should be replaced.

How long does it take to replace a boiler?

A standard replacement (wall-mounted combi boiler, equivalent location, compatible flue outlet) is completed in one day. If it requires adapting the flue or switching from atmospheric to condensing, it may take two days.

Do you repair boilers of all brands?

Yes, multi-brand service: Saunier Duval, Vaillant, Junkers, Baxi, Ferroli, Ariston, Beretta, Cointra, Domusa, Baxi Roca, and 6 other brands. Multi-brand service does not equate to official service unless expressly accredited by the brand.

What documentation does the installer need to provide?

After installation or replacement, the authorized installer provides an installation certificate, leak test, and, when applicable, communication to the gas distribution company. The installation is registered by a qualified installer in category IG-B or IG-C as appropriate.

Do I need to change the flue when replacing the boiler?

If the new boiler is a condensing type and the outlet is through the facade, in many cases the duct can be reused but the termination is replaced. Condensing expels flue gases at low temperature through white PVC and requires a condensate drain.

Do you need a boiler technician?

Actual diagnosis during visit. Fixed written estimate. Multibrand service with installer certified in category IG-B.

Scroll to the top