Ferroli Divatech Micro LN F24 D PCB Ref. 3980I626

Ferroli Divatech Micro LN F24 D PCB Ref. 3980I626

85 €VAT includedIn stock · 3 units

PCB (control board): refurbished spare part that controls the ignition, modulation, and safety features of the boiler. Useful if the boiler does not ignite, locks up, or the display is unresponsive. Compatible with DIVATECH MICRO LN F24 D, DOMIPROJECT F24 D, DOMIPROJECT C24 D (ref. 3980I626). Includes a one-year warranty and delivery within 2–4 working days in the EU.

1
Consult via WhatsApp
Delivery in 2–4 working days
1-year warranty
14-day return
Technical support

Key Data

Reference
3980I626
Brand
Ferroli
Type of part
PCBs (control boards)
Available units
3 units in stock
Status
Refurbished
Warranty
1 year
Shipping
2–4 working days (EU)
Return
14 days

The same part (ref. 3980I626) equips these models. Verified compatibility; check the reference before purchasing.

Divatech

  • DIVATECH MICRO LN F24 D

Domiproject

  • DOMIPROJECT F24 D
  • DOMIPROJECT C24 D

Easy

  • EASY F24 D

Essential

  • ESSENTIAL D24 E

Fault codes related to this part (not the entire boiler). They usually have more possible causes: first rule out electrodes, wiring/connections, and gas supply. Verified with ≥3 sources.

CodeWhat does it mean?Cause and diagnosis (this part)
A02Flame signal present with burner off.The PCB (ABM01A board) may give a false ionization reading due to a fault in the detection circuit or internal leakage; check wiring/electrode and, if it persists, measure ionization current and test/reprogram or replace the PCB.
F04Anomaly in the parameters of the control board.PCB parameters misconfigured/corrupted (EEPROM); check in technical menu and reprogram/autoset (e.g., parameters b**/q**); if it doesn't save or reappears, the PCB is damaged and must be replaced.
F05Anomaly in the parameters of the control board.Incorrect programming/parameterization of the PCB or internal fault of the control board; verify and correct parameters in the technical menu or load default values; if the anomaly persists after reprogramming, replace the PCB.
F07Anomaly in the parameters of the control board.Parameter/EEPROM error in the PCB causing control lockout; verify and reprogram parameters in the technical menu; if it reappears, confirm with temporary card substitution or replace the PCB.
A23Anomaly in the parameters of the control board.Incorrect programming/parameterization of the PCB (e.g., factory settings lost); check by performing a reset/programming of the board and, if not corrected, update or replace the PCB.
A24Anomaly in the parameters of the control board.Fault/alteration of the PCB programming that requires reparameterization or loading correct values; if the board does not allow recording or the error returns, replace the PCB.
How do I know if this PCB is for my boiler?
Verify the reference 3980I626 printed and ensure your model is on the list of compatible ones; also compare the connections with the original part. It is a B&P (Bertelli & Partners) part.
What is it used for?
The PCB controls the ignition, modulation, sensor readings, and safety features of the boiler.
Is the boiler not igniting, locking out, or is the control board unresponsive?
After ruling out mains voltage, fuse, and connectors, a damaged PCB causes lockouts, blackouts, or erratic display. Repair the external cause before installing the new one.
Which models is it suitable for?
Part shared by various models (see Compatibility). If your model does not appear, send us a photo of the marking and we will confirm it.
Installation and recommendations
After installation, a technician must adjust the service parameters (type of gas, power settings) and check combustion and safety features.
What does refurbished mean and what coverage does it have?
Part removed from a boiler out of service, inspected and tested. Includes 1-year warranty and 14-day return policy. Delivery within 2–4 working days in the EU.